An improved HarshawTLD™ extremity dosimeter - DXTRAD beta ring

被引:1
|
作者
Luo, Ling Z. [1 ]
Velbeck, Ken [1 ]
Rotunda, Joseph [1 ]
Esser, Reiner [2 ]
机构
[1] Thermo Fisher Sci, Oakwood Village, OH 44146 USA
[2] Thermo Fisher Sci, D-42857 Remscheid, Germany
关键词
Extremity; PTB type test; DXTRAD; Beta monitoring; HarshawTLD; PERFORMANCE; RADIATION; SYSTEM;
D O I
10.1016/j.radmeas.2011.04.036
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
An improved HarshawTLD (TM) extremity dosimeter system that is rugged in design and easy to wear is presented. This dosimeter is improved from the earlier version (2008) for personnel beta monitoring while still having full range photon performance. The dosimeter style, referred to as DXTRAD, is small in size and has identification by means of a circular barcode. It consists of a detector composed of a thin 7 mg cm(-2) monolayer of HarshawTLD-700H ((7)LiF:Mg,Cu,P) powder and a ring cap with a 3.3 mg cm(-2) entrance window. The use of the TLD-700H TLD material provides a good beta energy response as well as a flat energy response from low energy x-rays to high energy gamma rays. A new assembly tool that improves the consistency of dosimeter geometry and ruggedness for warm and cold sterilization is also developed. With the optimized design, this dosimeter is capable of meeting the stringent energy and angular response requirements of the Physikalisch Technische Bundesanstalt (PTB) for both betas and photons. Presented in this paper are the ISO-12974 and PTB type tests as well as additional operational tests, such as residue, reuse, warm and cold sterilization, and environmental leakage. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:621 / 625
页数:5
相关论文
共 50 条
  • [41] MIXED FIELD MULTIELEMENT BETA-GAMMA DOSIMETER DESIGN
    RAYES, IM
    STOEBE, TG
    RADIATION PROTECTION DOSIMETRY, 1986, 17 (1-4) : 39 - 42
  • [42] HEALTH PHYSICS DOSIMETER SYSTEMS FOR IMPROVED MEASUREMENT OF ABSORBED DOSES
    MAUSHART, R
    PIESCH, E
    HEALTH PHYSICS, 1966, 12 (12): : 1792 - +
  • [43] An improved abduction splint for the upper extremity
    Jordan, HH
    JOURNAL OF BONE AND JOINT SURGERY, 1944, 26 : 600 - 601
  • [44] IMPROVED GRAFTING TECHNIC FOR BURNS OF THE EXTREMITY
    MACOMBER, WB
    PATTON, HS
    AMERICAN JOURNAL OF SURGERY, 1947, 73 (06): : 684 - 689
  • [45] How To Assess the Real Extremities Dosimetry Based On the Results of a Dosimeter Ring ?
    Armando, M.
    Huet, A.
    Vial, F.
    Rannou, M.
    Valette, R.
    Hida, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S162 - S163
  • [46] AUTOMATED LOW-ENERGY PHOTON AND BETA-ENVIRONMENT DOSIMETER
    FIX, JJ
    MCCORMACK, WD
    HEALTH PHYSICS, 1984, 47 (01): : 175 - 175
  • [47] A SMALL, MULTI-ELEMENT FINGERTIP DOSIMETER FOR BETA-RADIATION
    COUCH, NW
    WATSON, JE
    HAMRICK, PE
    HEALTH PHYSICS, 1988, 55 (05): : 719 - 728
  • [48] Beta planar source quality assurance with the Fricke xylenol gel dosimeter
    Alva-Sanchez, Mirko S.
    de Oliveira, Lucas N.
    Petchevist, Paulo C.
    Moreira, Marco V.
    de Almeida, Adelaide
    RADIATION PHYSICS AND CHEMISTRY, 2014, 96 : 56 - 59
  • [49] MEASUREMENT OF BETA-ABSORBED DOSE USING TLD PERSONAL DOSIMETER
    MIYABE, K
    NOMURA, Y
    ISHIGURO, H
    HEALTH PHYSICS, 1984, 46 (06): : 1327 - 1327
  • [50] Development and efficacy testing of a new optically stimulated luminescence ring dosimeter and algorithm
    Chen, Li-Yen
    Hsu, Ching-Han
    Hsu, Fang-Yuh
    RADIATION MEASUREMENTS, 2019, 124 : 109 - 115