MEASUREMENT OF EXTREMITY DOSES OF NUCLEAR ENERGY WORKER BY USING RING DOSIMETER

被引:1
|
作者
Islam, M. Tahidul [1 ]
Ferdous, J. [2 ]
Haque, M. M. [1 ]
机构
[1] Univ Rajshahi, Dept Phys, Rajshahi 6205, Bangladesh
[2] Atom Energy Ctr, Hlth Phys Div, Dhaka, Bangladesh
关键词
STAFF; HAND; EXPOSURE;
D O I
10.1093/rpd/ncz283
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Finger doses can serve as a guide to suggest any needed modification in work practice to minimise radiation doses to the extremities. In the present study, radiation doses at the base of the middle finger of both hands of 20 nuclear energy workers handling Tc-99m-labelled compounds,I-125 and(131)I during various diagnostic and therapeutic procedures in nuclear medicine were measured. The laboratory assessments were carried out by means of thermoluminescence ring dosimetry in Health Physics Division, Atomic Energy Center, Dhaka. The recorded extremity doses were then compared to their routinely monitored whole-body doses. The average annual finger doses recorded in this study were found to be 10.7 +/- 8.2 and 12.7 +/- 12.9 mSv, respectively, for the left- and right-hand fingers, which are at least 12-fold higher than the average whole-body dose. There was, however, no extreme case found of health hazard to the workers' hand, which exceeds maximum dose limit 500 mSv/year given by the International Commission on Radiological Protection. On comparing the average annual finger doses at different labs, significantly higher average dose was recorded at isotope-dispensing lab (19.6 +/- 12.6 mSv/year) and then followed by gamma camera lab (13.2 +/- 12.1 mSv/year) and radioimmunoassay lab (7.0 +/- 5.5 mSv/year). These observations are fairly in good agreement with the reported results. The observations of the present study, therefore, may be implemented for the betterment of safety for the occupational workers in nuclear medicine facilities.
引用
收藏
页码:271 / 275
页数:5
相关论文
共 50 条
  • [1] Wrist dosimeter in nuclear medicine - An alternative for the ring dosimeter?
    Malgorzata, Wrzesien
    Jerzy, Olszewski
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 54 : 117 - 120
  • [2] An improved HarshawTLD™ extremity dosimeter - DXTRAD beta ring
    Luo, Ling Z.
    Velbeck, Ken
    Rotunda, Joseph
    Esser, Reiner
    RADIATION MEASUREMENTS, 2011, 46 (6-7) : 621 - 625
  • [3] Extremity doses of nuclear medicine personnel: a concern
    Gerrit J. Kemerink
    Filip Vanhavere
    Ilona Barth
    Felix M. Mottaghy
    European Journal of Nuclear Medicine and Molecular Imaging, 2012, 39 : 529 - 532
  • [4] Extremity doses of nuclear medicine personnel: a concern
    Kemerink, Gerrit J.
    Vanhavere, Filip
    Barth, Ilona
    Mottaghy, Felix M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 (03) : 529 - 532
  • [5] HEALTH PHYSICS DOSIMETER SYSTEMS FOR IMPROVED MEASUREMENT OF ABSORBED DOSES
    MAUSHART, R
    PIESCH, E
    HEALTH PHYSICS, 1966, 12 (12): : 1792 - +
  • [6] FBX CHEMICAL DOSIMETER FOR MEASUREMENT OF ABSORBED DOSES FROM RADIOPHARMACEUTICALS
    BENEDETTO, AR
    HARRIS, CR
    WAGGENER, RG
    NEFF, RD
    MEDICAL PHYSICS, 1983, 10 (04) : 549 - 549
  • [7] Energy Correction Factors for Silicon Semiconductor Dosimeter in Adult-male Phantom for Accurate Measurement of Organ Doses
    Kim, Chan Hyeong
    Cho, Sungkoo
    Choi, Sang Hyoun
    Kim, Jong Kyung
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 256 - 259
  • [8] Measurement 'quantity' for extremity doses - What's in a name?
    Goldfinch, EP
    RADIATION PROTECTION DOSIMETRY, 1997, 69 (03) : 163 - 164
  • [9] Basic study of an effective energy measurement method using a stacked thermoluminescence dosimeter
    Takagi, Hitomi
    Yanagisawa, Shin
    Koba, Yusuke
    Shinsho, Kiyomitsu
    RADIATION MEASUREMENTS, 2020, 133
  • [10] Measurement of glass dosimeter response for low energy photon using synchrotron radiations
    Asano, Y
    Sasamoto, N
    Nakane, Y
    Nakashima, H
    Sakamoto, Y
    Tanaka, S
    Namito, Y
    Ban, S
    Hirayama, H
    Nariyama, N
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 4, 1996, : D253 - D255