MEASUREMENT OF EXTREMITY DOSES OF NUCLEAR ENERGY WORKER BY USING RING DOSIMETER

被引:1
|
作者
Islam, M. Tahidul [1 ]
Ferdous, J. [2 ]
Haque, M. M. [1 ]
机构
[1] Univ Rajshahi, Dept Phys, Rajshahi 6205, Bangladesh
[2] Atom Energy Ctr, Hlth Phys Div, Dhaka, Bangladesh
关键词
STAFF; HAND; EXPOSURE;
D O I
10.1093/rpd/ncz283
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Finger doses can serve as a guide to suggest any needed modification in work practice to minimise radiation doses to the extremities. In the present study, radiation doses at the base of the middle finger of both hands of 20 nuclear energy workers handling Tc-99m-labelled compounds,I-125 and(131)I during various diagnostic and therapeutic procedures in nuclear medicine were measured. The laboratory assessments were carried out by means of thermoluminescence ring dosimetry in Health Physics Division, Atomic Energy Center, Dhaka. The recorded extremity doses were then compared to their routinely monitored whole-body doses. The average annual finger doses recorded in this study were found to be 10.7 +/- 8.2 and 12.7 +/- 12.9 mSv, respectively, for the left- and right-hand fingers, which are at least 12-fold higher than the average whole-body dose. There was, however, no extreme case found of health hazard to the workers' hand, which exceeds maximum dose limit 500 mSv/year given by the International Commission on Radiological Protection. On comparing the average annual finger doses at different labs, significantly higher average dose was recorded at isotope-dispensing lab (19.6 +/- 12.6 mSv/year) and then followed by gamma camera lab (13.2 +/- 12.1 mSv/year) and radioimmunoassay lab (7.0 +/- 5.5 mSv/year). These observations are fairly in good agreement with the reported results. The observations of the present study, therefore, may be implemented for the betterment of safety for the occupational workers in nuclear medicine facilities.
引用
收藏
页码:271 / 275
页数:5
相关论文
共 50 条
  • [21] Effect of dosimeter's position on occupational radiation extremity dose measurement for nuclear medicine workers during 18F-FDG preparation for PET/CT
    Salesses, Fabien
    Perez, Paul
    Maillard, Aline E.
    Blanchard, Julie
    Mallard, Sabine
    Bordenave, Laurence
    EJNMMI PHYSICS, 2016, 3 (01):
  • [22] Measures taken by the supervisory authority to reduce extremity doses in nuclear medicine facilities in Switzerland
    Stritt, Nicolas
    Linder, Reto
    RADIATION MEASUREMENTS, 2011, 46 (11) : 1315 - 1320
  • [23] Evaluation of institutional whole-body and extremity occupational radiation doses in nuclear medicine
    Bouchareb, Yassine
    Al-Mabsali, Jihad
    Al-Zeheimi, Hilal
    Al-Jabri, Aziza
    Tag, Naima
    Al-Dhuhli, Humoud
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (19) : 2318 - 2327
  • [24] MEASUREMENT OF THE EFFECTIVE DOSE EQUIVALENT IN A NUCLEAR-REACTOR ENVIRONMENT WITH A PERSONAL THERMOLUMINESCENT DOSIMETER
    WALSH, ML
    JOHNS, HE
    HEALTH PHYSICS, 1984, 46 (01): : 55 - 64
  • [25] Assessing doses to interventional radiologists using a personal dosimeter worn over a protective apron
    Stranden, E.
    Widmark, A.
    Sekse, T.
    ACTA RADIOLOGICA, 2008, 49 (04) : 415 - 418
  • [26] MEASUREMENT OF PERSONAL DOSE EQUIVALENT OF X AND GAMMA RADIATION BY RING DOSIMETER: RESULTS OF INTERCOMPARISON MEASUREMENTS
    Adamowicz, Malgorzata
    Papierz, Sylwia
    Kacprzyk, Janusz
    Kaminski, Zbigniew
    Zmyslony, Marek
    MEDYCYNA PRACY, 2013, 64 (05) : 631 - 637
  • [27] Estimating worker collective doses from a revised approach to managing commercial used nuclear fuel
    Burkhardt, Bethany
    Krahn, Steven
    Croft, Allen
    Sowder, Andrew
    Radwaste Solutions, 2015, 22 (01): : 40 - 48
  • [28] Precise measurement of nuclear isomers in the storage ring at GSI
    Sun, B.
    Bosch, F.
    Boutin, D.
    Brandau, C.
    Chen, L.
    Dimopoulou, C.
    Fabian, B.
    Geissel, H.
    Knoebel, R.
    Kozhuharov, C.
    Kurcewicz, J.
    Litvinov, S. A.
    Litvinov, Yu. A.
    Meng, J.
    Muenzenberg, G.
    Nociforo, C.
    Nolden, F.
    Plass, W. R.
    Scheidenberger, C.
    Steck, M.
    Walker, P. M.
    Weick, H.
    Winckler, N.
    Winkler, M.
    NUCLEAR PHYSICS A, 2010, 834 (1-4) : 476C - 478C
  • [29] Effective Doses for Extremity Imaging Using Cone Beam CT Scanners
    Dave, J.
    Minch, T.
    MEDICAL PHYSICS, 2022, 49 (06) : E631 - E631
  • [30] MEASUREMENT OF NUCLEAR ENERGY CHANGE VALUES
    POLLARD, E
    NUCLEONICS, 1948, 2 (04): : 1 - 17