Myocardial viability: Breath-hold 3D MR imaging of delayed hyperenhancement with variable sampling in time

被引:47
|
作者
Foo, TKF [1 ]
Stanley, DW
Castillo, E
Rochitte, CE
Wang, Y
Lima, JAC
Bluemke, DA
Wu, KC
机构
[1] GE Med Syst, Appl Sic Lab, Baltimore, MD USA
[2] Johns Hopkins Univ, Dept Radiol, Baltimore, MD 21287 USA
[3] Johns Hopkins Univ, Dept Cardiol, Baltimore, MD 21287 USA
[4] Inst Coracao, Dept Cardiol, Sao Paulo, Brazil
[5] Peoples Hosp, Dept Radiol, Beijing, Peoples R China
关键词
heart; MR; magnetic resonance (MR); contrast enhancement; three-dimensional; myocardium; infarction;
D O I
10.1148/radiol.2303021411
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A method for visualizing myocardial infarction with a three-dimensional (3D) breath-hold gated acquisition was examined. By using variable sampling in time, whole heart coverage with a single volume acquisition was achieved in 24 heart beats. In a study of 35 patients, in whom 3D volume acquisition was compared with a two-dimensional (2D) acquisition, all regions of myocardial infarction were correctly identified at 3D examination. The mean imaging time for 12 section locations was 8.0 minutes +/- 3.0 with a 2D approach compared with 22 seconds +/- 4 with a 3D approach (P < .001). Advantages were also noted for infarct contrast-to-noise ratio: 60 +/- 37 for 3D versus 33 +/- 20 for 2D imaging (P < .001). No significant differences (P > .05) were noted at qualitative assessment of myocardial suppression, endocardial border visualization, respiratory and cardiac motion artifacts, or confidence of transmurality of the infarct. (C) RSNA, 2004.
引用
收藏
页码:845 / 851
页数:7
相关论文
共 50 条
  • [31] Breath-hold 3D contrast-enhanced and respiratory-triggered fast spin-echo MR imaging for renal cell carcinoma
    Takahashi, S
    Narumi, Y
    Tsuda, K
    Kim, T
    Furukawa, T
    Nakamura, H
    RADIOLOGY, 1998, 209P : 301 - 301
  • [32] Single breath-hold assessment of cardiac function using an accelerated 3D single breath-hold acquisition technique - comparison of an intravascular and extravascular contrast agent
    Marcus R Makowski
    Andrea J Wiethoff
    Christian HP Jansen
    Sergio Uribe
    Victoria Parish
    Andreas Schuster
    Rene M Botnar
    Aaron Bell
    Christoph Kiesewetter
    Reza Razavi
    Tobias Schaeffter
    Gerald F Greil
    Journal of Cardiovascular Magnetic Resonance, 14
  • [33] Single breath-hold assessment of cardiac function using an accelerated 3D single breath-hold acquisition technique - comparison of an intravascular and extravascular contrast agent
    Makowski, Marcus R.
    Wiethoff, Andrea J.
    Jansen, Christian H. P.
    Uribe, Sergio
    Parish, Victoria
    Schuster, Andreas
    Botnar, Rene M.
    Bell, Aaron
    Kiesewetter, Christoph
    Razavi, Reza
    Schaeffter, Tobias
    Greil, Gerald F.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2012, 14
  • [34] Comparison of Compressed Sensing and Gradient and Spin-Echo in Breath-Hold 3D MR Cholangiopancreatography: Qualitative and Quantitative Analysis
    Jang, Weon
    Song, Ji Soo
    Kim, Sang Heon
    Do Yang, Jae
    DIAGNOSTICS, 2021, 11 (04)
  • [35] MR angiography of internal carotid arteries: Breath-hold Gd-enhanced 3D fast imaging with steady-state precession versus unenhanced 2D and 3D time-of-flight techniques
    Sardanelli, F
    Zandrino, F
    Parodi, RC
    De Caro, G
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (02) : 208 - 215
  • [36] Rapid evaluation of right and left ventricular function and mass using real-time True-FISP Cine MR imaging without breath-hold: Comparison with segmented True-FISP Cine MR imaging with breath-hold
    Hori, Y
    Yamada, N
    Higashi, M
    Hirai, N
    Nakatani, S
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2003, 5 (03) : 439 - 450
  • [37] Comparing compressed sensing breath-hold 3D MR cholangiopancreatography with two parallel imaging MRCP strategies in main pancreatic duct and common bile duct
    Chen, Zhiyong
    Sun, Bin
    Xue, Yunjing
    Duan, Qing
    Zheng, Enshuang
    He, Yingying
    Li, Guijin
    Zhang, Zhongshuai
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 142
  • [38] Breath-hold 3D gradient-echo MR imaging of the lung parenchyma: Evaluation of reproducibility of image quality in normals and preliminary observations in patients with disease
    Semelka, RC
    Balci, NC
    Wilber, KP
    Fisher, LL
    Brown, MA
    Gomez-Caminero, A
    Molina, PL
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 11 (02): : 195 - 200
  • [39] Feasibility of 3D Breath-Hold MR Cholangiopancreatography with a Spatially Selective Radiofrequency Excitation Pulse: Prospective Comparison with Parallel Imaging Technique and Compressed Sensing Method
    Chen, Zhiyong
    Xue, Yunjing
    Wu, Yuxin
    Duan, Qing
    Zheng, Enshuang
    He, Yingying
    Li, Guijin
    Song, Yang
    Sun, Bin
    ACADEMIC RADIOLOGY, 2022, 29 (12) : E289 - E295
  • [40] Clinical feasibility of 3D-QALAS - Single breath-hold 3D myocardial T1 and T2-mapping
    Kvernby, Sofia
    Warntjes, Marcel
    Engvall, Jan
    Carlhall, Carl-Johan
    Ebbers, Tino
    MAGNETIC RESONANCE IMAGING, 2017, 38 : 13 - 20