Breath-hold 3D gradient-echo MR imaging of the lung parenchyma: Evaluation of reproducibility of image quality in normals and preliminary observations in patients with disease

被引:0
|
作者
Semelka, RC [1 ]
Balci, NC [1 ]
Wilber, KP [1 ]
Fisher, LL [1 ]
Brown, MA [1 ]
Gomez-Caminero, A [1 ]
Molina, PL [1 ]
机构
[1] Univ N Carolina, Dept Radiol, Chapel Hill, NC 27599 USA
来源
关键词
lung; MR; nodule; pulmonary arteries;
D O I
10.1002/(SICI)1522-2586(200002)11:2<195::AID-JMRI18>3.0.CO;2-Q
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study evaluates the reproducibility and image quality of a three-dimensional (3D) gradient-echo sequence for imaging the lung parenchyma, with and without gadolinium administration, using a 2D spoiled gradient-echo sequence for comparison. Twenty patients without lung disease (normals) and five patients with lung disease [lung disease] underwent paired 2D and 3D gradient-echo sequences, without contrast (24 patients) and with contrast (18 patients). Images were retrospectively reviewed independently in a blinded fashion by two Investigators. Artifacts and demonstration of central lung, peripheral lung, heart, pulmonary arteries, and esophagus were evaluated. Image quality of the central lung was rated as fair or good in 5 and 4 (reader one and two) patients with non-contrast 2D gradient-echo, 24 and 25 patients with non-contrast 3D gradient-echo, 3 and 1 patient(s) with contrast-enhanced 2D gradient-echo, and 19 and 19 patients with contrast-enhanced 3D gradient-echo imaging. Differences in image quality between 2D and 3D sequences were significant (P < 0.001). Heart-related phase artifacts were negligible in 2 and 0 patients with non-contrast 2D gradient-echo, 23 and 25 patients with non-contrast 3D gradient-echo, 0 and 0 patients with contrast-enhanced 2D gradient-echo, and 17 and 19 patients with contrast-enhanced 3D gradient-echo imaging. Differences in heart-related phase artifact in the central lung between 2D and 3D sequences were significant (P = 0.001). Infiltrates, lung cancer, and pulmonary metastasis were better shown on the gadolinium-enhanced 3D gradient-echo sequences than on the other sequences. Breath-hold 3D gradient-echo imaging results in good image quality and negligible image artifacts and is superior to 2D spoiled gradient-echo imaging. Preliminary results in patients with disease appear promising.
引用
收藏
页码:195 / 200
页数:6
相关论文
共 50 条
  • [1] Magnetic resonance imaging of pulmonary parenchymal disease using a modified breath-hold 3D gradient-echo technique: Initial observations
    Bader, TR
    Semelka, RC
    Pedro, MS
    Armao, DM
    Brown, MA
    Molina, PL
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (01) : 31 - 38
  • [2] MR evaluation of coronary stents with navigator echo and breath-hold cine gradient-echo techniques
    F. Sardanelli
    F. Zandrino
    G. Molinari
    A. Iozzelli
    M. Balbi
    A. Barsotti
    [J]. European Radiology, 2002, 12 : 193 - 200
  • [3] MR evaluation of coronary stents with navigator echo and breath-hold cine gradient-echo techniques
    Sardanelli, F
    Zandrino, F
    Molinari, G
    Iozzelli, A
    Balbi, M
    Barsotti, A
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (01) : 193 - 200
  • [4] Breath-hold 3D MR angiography of the renal vasculature using a contrast-enhanced multiecho gradient-echo technique
    Papachristopoulos, G
    Bis, KG
    Shetty, AN
    Ross, M
    Bagga, H
    Shirkhoda, A
    Laub, G
    [J]. INVESTIGATIVE RADIOLOGY, 1999, 34 (12) : 731 - 738
  • [5] Wavelet encoding for 3D gradient-echo MR imaging
    Gelman, N
    Wood, ML
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) : 613 - 619
  • [6] Fat-Suppressed 3D T1-Weighted Gradient-Echo Imaging of the Cartilage With a Volumetric Interpolated Breath-Hold Examination
    Zheng, Zhuo-Zhao
    Shan, Han
    Li, Xuan
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05) : W414 - W419
  • [7] Comparison of Compressed Sensing and Gradient and Spin-Echo in Breath-Hold 3D MR Cholangiopancreatography: Qualitative and Quantitative Analysis
    Jang, Weon
    Song, Ji Soo
    Kim, Sang Heon
    Do Yang, Jae
    [J]. DIAGNOSTICS, 2021, 11 (04)
  • [8] Dual-contrast single breath-hold 3D abdominal MR imaging
    Winkelmann, Richard
    Boernert, Peter
    De Becker, Jan
    Hoogeveen, Romhild
    Mazurkewitz, Peter
    Doessel, Olaf
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2006, 19 (06) : 297 - 304
  • [9] Dual-contrast single breath-hold 3D abdominal MR imaging
    Richard Winkelmann
    Peter Börnert
    Jan De Becker
    Romhild Hoogeveen
    Peter Mazurkewitz
    Olaf Dössel
    [J]. Magnetic Resonance Materials in Physics, Biology and Medicine, 2006, 19 : 297 - 304
  • [10] MR Imaging of the chest using a contrast-enhanced breath-hold modified three-dimensional gradient-echo technique: Comparison with two-dimensional gradient-echo technique and multidetector CT
    Karabulut, N
    Martin, DR
    Yang, M
    Tallaksen, RJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (05) : 1225 - 1233