Feasibility of 3D Breath-Hold MR Cholangiopancreatography with a Spatially Selective Radiofrequency Excitation Pulse: Prospective Comparison with Parallel Imaging Technique and Compressed Sensing Method

被引:1
|
作者
Chen, Zhiyong [1 ]
Xue, Yunjing [1 ]
Wu, Yuxin [1 ]
Duan, Qing [1 ]
Zheng, Enshuang [1 ]
He, Yingying [1 ]
Li, Guijin [2 ]
Song, Yang [3 ]
Sun, Bin [1 ]
机构
[1] Fujian Med Univ Union Hosp, Dept Radiol, 29 Xin Quan Rd, Fuzhou 350001, Peoples R China
[2] Siemens Healthineers Ltd, MR Applicat, Guangzhou, Peoples R China
[3] Siemens Healthineers Ltd, MR Sci Mkt, Shanghai, Peoples R China
关键词
Magnetic resonance cholangiopancreatography; Compressed sensing; Breath hold; MAGNETIC-RESONANCE CHOLANGIOPANCREATOGRAPHY; ACQUISITION TIME; SEQUENCE; QUALITY;
D O I
10.1016/j.acra.2022.03.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: The purpose of the present study was to evaluate the clinical feasibility of the modified 3D breath-hold magnetic res-onance cholangiopancreatography with parallel imaging (3D-BH-PI-MRCP) using a spatially selective radiofrequency excitation pulse in patients with suspected pancreaticobiliary diseases. Moreover, we also compared its image quality with those of the original 3D-BH-PI-MRCP with a non-selective exciting pulse and the 3D breath hold compressed sensing magnetic resonance cholangiopancreatography (3D-BH-CS-MRCP).Materials and Methods: Between January 2021 and July 2021, 106 patients prospectively underwent modified 3D-BH-PI-MRCP, original 3D-BH-PI-MRCP and 3D-BH-CS-MRCP at 3T in this study. The Friedman test was performed to compare the contrast, signal-to-noise -ratio (SNR), and contrast-noise-ratio, overall image quality, and duct visualization among the three protocols.Results: The contrast ratio, SNR and contrast-to-noise ratio of the common bile duct differed significantly among the three sequences (p < 0.001). Compared to the 3D-BH-CS-MRCP protocol, the overall imaging quality of the two 3D-BH-PI-MRCP was higher but not significantly different. The scores for the anterior and posterior branches visualization were significantly higher in the original 3D-BH-PI-MRCP compared to the 3D-BH-CS-MRCP, but were no significant differences between the modified 3D-BH-PI-MRCP and the 3D-BH-CS-MRCP.Conclusion: The modified 3D-BH-PI-MRCP with a spatially selective radiofrequency excitation pulse could provide comparable image quality to the original 3D-BH-PI-MRCP and the 3D-BH-CS-MRCP during a single breath hold (22 seconds), and showed improved SNR and superior visualization of the pancreaticobiliary tree.
引用
收藏
页码:E289 / E295
页数:7
相关论文
共 50 条
  • [1] Comparison of Compressed Sensing and Gradient and Spin-Echo in Breath-Hold 3D MR Cholangiopancreatography: Qualitative and Quantitative Analysis
    Jang, Weon
    Song, Ji Soo
    Kim, Sang Heon
    Do Yang, Jae
    DIAGNOSTICS, 2021, 11 (04)
  • [2] Rapid 3D breath-hold MR cholangiopancreatography using deep learning–constrained compressed sensing reconstruction
    Yu Zhang
    Wanlin Peng
    Yi Xiao
    Yue Ming
    Kehang Ma
    Sixian Hu
    Wen Zeng
    Lingming Zeng
    Zejun Liang
    Xiaoyong Zhang
    Chunchao Xia
    Zhenlin Li
    European Radiology, 2023, 33 : 2500 - 2509
  • [3] Comparing compressed sensing breath-hold 3D MR cholangiopancreatography with two parallel imaging MRCP strategies in main pancreatic duct and common bile duct
    Chen, Zhiyong
    Sun, Bin
    Xue, Yunjing
    Duan, Qing
    Zheng, Enshuang
    He, Yingying
    Li, Guijin
    Zhang, Zhongshuai
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 142
  • [4] Rapid 3D breath-hold MR cholangiopancreatography using deep learning-constrained compressed sensing reconstruction
    Zhang, Yu
    Peng, Wanlin
    Xiao, Yi
    Ming, Yue
    Ma, Kehang
    Hu, Sixian
    Zeng, Wen
    Zeng, Lingming
    Liang, Zejun
    Zhang, Xiaoyong
    Xia, Chunchao
    Li, Zhenlin
    EUROPEAN RADIOLOGY, 2023, 33 (04) : 2500 - 2509
  • [5] Optimized Breath-Hold Compressed-Sensing 3D MR Cholangiopancreatography at 3T: Image Quality Analysis and Clinical Feasibility Assessment
    Song, Ji Soo
    Kim, Seung Hun
    Kuehn, Bernd
    Paek, Mun Young
    DIAGNOSTICS, 2020, 10 (06)
  • [6] MR cholangiopancreatography: prospective comparison of a breath-hold 2D projection technique with diagnostic ERCP
    Lomas, DJ
    Bearcroft, PWP
    Gimson, AE
    EUROPEAN RADIOLOGY, 1999, 9 (07) : 1411 - 1417
  • [7] MR cholangiopancreatography: prospective comparison of a breath-hold 2D projection technique with diagnostic ERCP
    D. J. Lomas
    P. W. P. Bearcroft
    A. E. Gimson
    European Radiology, 1999, 9 : 1411 - 1417
  • [8] Breath-hold compressed-sensing 3D MR cholangiopancreatography compared to free-breathing 3D MR cholangiopancreatography: prospective study of image quality and diagnostic performance in pancreatic disorders
    Mannes, Ines
    Dallongeville, Axel
    Badat, Neesmah
    Beaussier, Helene
    Chatellier, Gilles
    Zins, Marc
    ABDOMINAL RADIOLOGY, 2020, 45 (04) : 1082 - 1091
  • [9] Breath-hold compressed-sensing 3D MR cholangiopancreatography compared to free-breathing 3D MR cholangiopancreatography: prospective study of image quality and diagnostic performance in pancreatic disorders
    Inès Mannes
    Axel Dallongeville
    Neesmah Badat
    Hélène Beaussier
    Gilles Chatellier
    Marc Zins
    Abdominal Radiology, 2020, 45 : 1082 - 1091
  • [10] Comparison of respiratory-triggered 3D MR cholangiopancreatography and breath-hold compressed-sensing 3D MR cholangiopancreatography at 1.5 T and 3 T and impact of individual factors on image quality
    Blaise, Helene
    Remen, Thomas
    Ambarki, Khalid
    Weiland, Elisabeth
    Kuehn, Bernd
    Orry, Xavier
    Laurent, Valerie
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 142