Feasibility of 3D Breath-Hold MR Cholangiopancreatography with a Spatially Selective Radiofrequency Excitation Pulse: Prospective Comparison with Parallel Imaging Technique and Compressed Sensing Method

被引:1
|
作者
Chen, Zhiyong [1 ]
Xue, Yunjing [1 ]
Wu, Yuxin [1 ]
Duan, Qing [1 ]
Zheng, Enshuang [1 ]
He, Yingying [1 ]
Li, Guijin [2 ]
Song, Yang [3 ]
Sun, Bin [1 ]
机构
[1] Fujian Med Univ Union Hosp, Dept Radiol, 29 Xin Quan Rd, Fuzhou 350001, Peoples R China
[2] Siemens Healthineers Ltd, MR Applicat, Guangzhou, Peoples R China
[3] Siemens Healthineers Ltd, MR Sci Mkt, Shanghai, Peoples R China
关键词
Magnetic resonance cholangiopancreatography; Compressed sensing; Breath hold; MAGNETIC-RESONANCE CHOLANGIOPANCREATOGRAPHY; ACQUISITION TIME; SEQUENCE; QUALITY;
D O I
10.1016/j.acra.2022.03.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: The purpose of the present study was to evaluate the clinical feasibility of the modified 3D breath-hold magnetic res-onance cholangiopancreatography with parallel imaging (3D-BH-PI-MRCP) using a spatially selective radiofrequency excitation pulse in patients with suspected pancreaticobiliary diseases. Moreover, we also compared its image quality with those of the original 3D-BH-PI-MRCP with a non-selective exciting pulse and the 3D breath hold compressed sensing magnetic resonance cholangiopancreatography (3D-BH-CS-MRCP).Materials and Methods: Between January 2021 and July 2021, 106 patients prospectively underwent modified 3D-BH-PI-MRCP, original 3D-BH-PI-MRCP and 3D-BH-CS-MRCP at 3T in this study. The Friedman test was performed to compare the contrast, signal-to-noise -ratio (SNR), and contrast-noise-ratio, overall image quality, and duct visualization among the three protocols.Results: The contrast ratio, SNR and contrast-to-noise ratio of the common bile duct differed significantly among the three sequences (p < 0.001). Compared to the 3D-BH-CS-MRCP protocol, the overall imaging quality of the two 3D-BH-PI-MRCP was higher but not significantly different. The scores for the anterior and posterior branches visualization were significantly higher in the original 3D-BH-PI-MRCP compared to the 3D-BH-CS-MRCP, but were no significant differences between the modified 3D-BH-PI-MRCP and the 3D-BH-CS-MRCP.Conclusion: The modified 3D-BH-PI-MRCP with a spatially selective radiofrequency excitation pulse could provide comparable image quality to the original 3D-BH-PI-MRCP and the 3D-BH-CS-MRCP during a single breath hold (22 seconds), and showed improved SNR and superior visualization of the pancreaticobiliary tree.
引用
收藏
页码:E289 / E295
页数:7
相关论文
共 50 条
  • [21] Navigator-triggered and breath-hold 3D MRCP using compressed sensing: image quality and method selection factor assessment
    Morimoto, Daisuke
    Hyodo, Tomoko
    Kamata, Ken
    Kadoba, Tomoya
    Itoh, Makoto
    Fukushima, Hiroyuki
    Chiba, Yasutaka
    Takenaka, Mamoru
    Mochizuki, Tomohiro
    Ueda, Yu
    Miyagoshi, Keizou
    Kudo, Masatoshi
    Ishii, Kazunari
    ABDOMINAL RADIOLOGY, 2020, 45 (10) : 3081 - 3091
  • [22] Navigator-triggered and breath-hold 3D MRCP using compressed sensing: image quality and method selection factor assessment
    Daisuke Morimoto
    Tomoko Hyodo
    Ken Kamata
    Tomoya Kadoba
    Makoto Itoh
    Hiroyuki Fukushima
    Yasutaka Chiba
    Mamoru Takenaka
    Tomohiro Mochizuki
    Yu Ueda
    Keizou Miyagoshi
    Masatoshi Kudo
    Kazunari Ishii
    Abdominal Radiology, 2020, 45 : 3081 - 3091
  • [23] Comparison of breath-hold 3D and retrospectively respiratory gated 3D MR coronary angiography with conventional coronary arteriography
    Wielopolski, PA
    VanGuens, RJ
    DeFeijter, PJ
    DeBruin, HG
    Bongaerts, AH
    Oudkerk, M
    RADIOLOGY, 1997, 205 : 59 - 59
  • [24] Single breath-hold assessment of cardiac function using an accelerated 3D single breath-hold acquisition technique - comparison of an intravascular and extravascular contrast agent
    Marcus R Makowski
    Andrea J Wiethoff
    Christian HP Jansen
    Sergio Uribe
    Victoria Parish
    Andreas Schuster
    Rene M Botnar
    Aaron Bell
    Christoph Kiesewetter
    Reza Razavi
    Tobias Schaeffter
    Gerald F Greil
    Journal of Cardiovascular Magnetic Resonance, 14
  • [25] Single breath-hold assessment of cardiac function using an accelerated 3D single breath-hold acquisition technique - comparison of an intravascular and extravascular contrast agent
    Makowski, Marcus R.
    Wiethoff, Andrea J.
    Jansen, Christian H. P.
    Uribe, Sergio
    Parish, Victoria
    Schuster, Andreas
    Botnar, Rene M.
    Bell, Aaron
    Kiesewetter, Christoph
    Razavi, Reza
    Schaeffter, Tobias
    Greil, Gerald F.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2012, 14
  • [26] Whole-Heart Cine MRI in a Single Breath-Hold - A Compressed Sensing Accelerated 3D Acquisition Technique for Assessment of Cardiac Function
    Wech, T.
    Pickl, W.
    Tran-Gia, J.
    Ritter, C.
    Beer, M.
    Hahn, D.
    Koestler, H.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (01): : 37 - 41
  • [27] Shortening MR image acquisition time for volumetric interpolated breath-hold examination with a recently developed parallel imaging reconstruction technique: Clinical feasibility
    McKenzie, CA
    Lim, D
    Ransil, BJ
    Morrin, M
    Pedrosa, I
    Yeh, EN
    Sodickson, DK
    Rofsky, NM
    RADIOLOGY, 2004, 230 (02) : 589 - 594
  • [28] Feasibility of 3D Navigator-Triggered Magnetic Resonance Cholangiopancreatography With Combined Parallel Imaging and Compressed Sensing Reconstruction at 3T
    Seo, Nieun
    Park, Mi-Suk
    Han, Kyunghwa
    Kim, Dongeun
    King, Kevin F.
    Choi, Jin-Young
    Kim, Honsoul
    Kim, Hye Jin
    Lee, Minsu
    Bae, Heejin
    Kim, Myeong-Jin
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (05) : 1289 - 1297
  • [29] Isotropic 3D T2-weighted MR cholangiopancreatography with parallel imaging: Feasibility study
    Zhang, Jingbo
    Israel, Gary M.
    Hecht, Elizabeth M.
    Krinsky, Glenn A.
    Babb, James S.
    Lee, Vivian S.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (06) : 1564 - 1570
  • [30] Contrast-enhanced, ultrafast 3D pulmonary MR angiography in a single breath-hold: Initial assessment of imaging performance
    Steiner, P
    McKinnon, GC
    Romanowski, B
    Goehde, SC
    Hany, T
    Debatin, JF
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (01) : 177 - 182