Feasibility of 3D Breath-Hold MR Cholangiopancreatography with a Spatially Selective Radiofrequency Excitation Pulse: Prospective Comparison with Parallel Imaging Technique and Compressed Sensing Method

被引:1
|
作者
Chen, Zhiyong [1 ]
Xue, Yunjing [1 ]
Wu, Yuxin [1 ]
Duan, Qing [1 ]
Zheng, Enshuang [1 ]
He, Yingying [1 ]
Li, Guijin [2 ]
Song, Yang [3 ]
Sun, Bin [1 ]
机构
[1] Fujian Med Univ Union Hosp, Dept Radiol, 29 Xin Quan Rd, Fuzhou 350001, Peoples R China
[2] Siemens Healthineers Ltd, MR Applicat, Guangzhou, Peoples R China
[3] Siemens Healthineers Ltd, MR Sci Mkt, Shanghai, Peoples R China
关键词
Magnetic resonance cholangiopancreatography; Compressed sensing; Breath hold; MAGNETIC-RESONANCE CHOLANGIOPANCREATOGRAPHY; ACQUISITION TIME; SEQUENCE; QUALITY;
D O I
10.1016/j.acra.2022.03.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: The purpose of the present study was to evaluate the clinical feasibility of the modified 3D breath-hold magnetic res-onance cholangiopancreatography with parallel imaging (3D-BH-PI-MRCP) using a spatially selective radiofrequency excitation pulse in patients with suspected pancreaticobiliary diseases. Moreover, we also compared its image quality with those of the original 3D-BH-PI-MRCP with a non-selective exciting pulse and the 3D breath hold compressed sensing magnetic resonance cholangiopancreatography (3D-BH-CS-MRCP).Materials and Methods: Between January 2021 and July 2021, 106 patients prospectively underwent modified 3D-BH-PI-MRCP, original 3D-BH-PI-MRCP and 3D-BH-CS-MRCP at 3T in this study. The Friedman test was performed to compare the contrast, signal-to-noise -ratio (SNR), and contrast-noise-ratio, overall image quality, and duct visualization among the three protocols.Results: The contrast ratio, SNR and contrast-to-noise ratio of the common bile duct differed significantly among the three sequences (p < 0.001). Compared to the 3D-BH-CS-MRCP protocol, the overall imaging quality of the two 3D-BH-PI-MRCP was higher but not significantly different. The scores for the anterior and posterior branches visualization were significantly higher in the original 3D-BH-PI-MRCP compared to the 3D-BH-CS-MRCP, but were no significant differences between the modified 3D-BH-PI-MRCP and the 3D-BH-CS-MRCP.Conclusion: The modified 3D-BH-PI-MRCP with a spatially selective radiofrequency excitation pulse could provide comparable image quality to the original 3D-BH-PI-MRCP and the 3D-BH-CS-MRCP during a single breath hold (22 seconds), and showed improved SNR and superior visualization of the pancreaticobiliary tree.
引用
收藏
页码:E289 / E295
页数:7
相关论文
共 50 条
  • [31] Feasibility of integrating high-spatial-resolution 3D breath-hold coronary MR angiography with myocardial perfusion and viability examinations
    Foo, TKF
    Ho, VB
    Saranathan, M
    Cheng, LQ
    Sakuma, H
    Kraitchman, DL
    Wu, KC
    Bluemke, DA
    RADIOLOGY, 2005, 235 (03) : 1025 - 1030
  • [32] Comparison of Compressed Sensing Accelerated MR Elastography to Standard Breath-Hold 2D Gradient Recalled Echo MRE for Estimating Liver Stiffness (LS)
    Zhang, J.
    Akselrod, D.
    Tam, J.
    Gonyea, J.
    Hipko, S.
    Bazylewicz, M.
    MEDICAL PHYSICS, 2022, 49 (06) : E144 - E144
  • [33] Feasibility and performance of breath-hold 3D TRUE-FISP coronary MRA using self-calibrating parallel acquisition
    Park, J
    McCarthy, R
    Li, DB
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (01) : 7 - 13
  • [34] Compressed sensing for breath-hold high-resolution hepatobiliary phase imaging: image noise, artifact, biliary anatomy evaluation, and focal lesion detection in comparison with parallel imaging
    Moon Hyung Choi
    Bohyun Kim
    Dongyeob Han
    Young Joon Lee
    Abdominal Radiology, 2022, 47 : 133 - 142
  • [35] Compressed sensing for breath-hold high-resolution hepatobiliary phase imaging: image noise, artifact, biliary anatomy evaluation, and focal lesion detection in comparison with parallel imaging
    Choi, Moon Hyung
    Kim, Bohyun
    Han, Dongyeob
    Lee, Young Joon
    ABDOMINAL RADIOLOGY, 2022, 47 (01) : 133 - 142
  • [36] Breath-hold 3D MR angiography of the renal vasculature using a contrast-enhanced multiecho gradient-echo technique
    Papachristopoulos, G
    Bis, KG
    Shetty, AN
    Ross, M
    Bagga, H
    Shirkhoda, A
    Laub, G
    INVESTIGATIVE RADIOLOGY, 1999, 34 (12) : 731 - 738
  • [37] BREATH-HOLD 3D STAR MR-ANGIOGRAPHY OF THE RENAL-ARTERIES USING SEGMENTED ECHO-PLANAR IMAGING
    WIELOPOLSKI, PA
    ADAMIS, M
    PRASAD, P
    GAA, J
    EDELMAN, R
    MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (03) : 432 - 438
  • [38] Dynamic breath-hold 3D contrast-enhanced renal MR imaging: Comprehensive, time-efficient renal evaluation
    Rofsky, NM
    Weinreb, JC
    Krinsky, GA
    DeCorato, DR
    Earls, JP
    Bosniak, MA
    RADIOLOGY, 1996, 201 : 105 - 105
  • [39] Diagnostic accuracy of 3D breath-hold MR cholangiography using compressed sensing acceleration in visualizing non-dilated biliary system in living donor liver transplantation donors
    Ono, Ayako
    Arizono, Shigeki
    Kohno, Shigeshi
    Nakai, Hirotsugu
    Isoda, Hiroyoshi
    Kuehn, Bernd
    Togashi, Kaori
    ACTA RADIOLOGICA, 2019, 60 (10) : 1209 - 1215
  • [40] Prospective comparison of color-Doppler ultrasound and breath-hold dynamic gadolinium-enhanced 3D MR angiography (MRA) in evaluation of renal artery stenosis
    De Cobelli, F
    Venturini, M
    Angeli, E
    Salvioni, M
    Vanzulli, A
    Del Maschio, A
    RADIOLOGY, 1998, 209P : 185 - 185