共 50 条
Feasibility of 3D Breath-Hold MR Cholangiopancreatography with a Spatially Selective Radiofrequency Excitation Pulse: Prospective Comparison with Parallel Imaging Technique and Compressed Sensing Method
被引:1
|作者:
Chen, Zhiyong
[1
]
Xue, Yunjing
[1
]
Wu, Yuxin
[1
]
Duan, Qing
[1
]
Zheng, Enshuang
[1
]
He, Yingying
[1
]
Li, Guijin
[2
]
Song, Yang
[3
]
Sun, Bin
[1
]
机构:
[1] Fujian Med Univ Union Hosp, Dept Radiol, 29 Xin Quan Rd, Fuzhou 350001, Peoples R China
[2] Siemens Healthineers Ltd, MR Applicat, Guangzhou, Peoples R China
[3] Siemens Healthineers Ltd, MR Sci Mkt, Shanghai, Peoples R China
关键词:
Magnetic resonance cholangiopancreatography;
Compressed sensing;
Breath hold;
MAGNETIC-RESONANCE CHOLANGIOPANCREATOGRAPHY;
ACQUISITION TIME;
SEQUENCE;
QUALITY;
D O I:
10.1016/j.acra.2022.03.006
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Rationale and Objectives: The purpose of the present study was to evaluate the clinical feasibility of the modified 3D breath-hold magnetic res-onance cholangiopancreatography with parallel imaging (3D-BH-PI-MRCP) using a spatially selective radiofrequency excitation pulse in patients with suspected pancreaticobiliary diseases. Moreover, we also compared its image quality with those of the original 3D-BH-PI-MRCP with a non-selective exciting pulse and the 3D breath hold compressed sensing magnetic resonance cholangiopancreatography (3D-BH-CS-MRCP).Materials and Methods: Between January 2021 and July 2021, 106 patients prospectively underwent modified 3D-BH-PI-MRCP, original 3D-BH-PI-MRCP and 3D-BH-CS-MRCP at 3T in this study. The Friedman test was performed to compare the contrast, signal-to-noise -ratio (SNR), and contrast-noise-ratio, overall image quality, and duct visualization among the three protocols.Results: The contrast ratio, SNR and contrast-to-noise ratio of the common bile duct differed significantly among the three sequences (p < 0.001). Compared to the 3D-BH-CS-MRCP protocol, the overall imaging quality of the two 3D-BH-PI-MRCP was higher but not significantly different. The scores for the anterior and posterior branches visualization were significantly higher in the original 3D-BH-PI-MRCP compared to the 3D-BH-CS-MRCP, but were no significant differences between the modified 3D-BH-PI-MRCP and the 3D-BH-CS-MRCP.Conclusion: The modified 3D-BH-PI-MRCP with a spatially selective radiofrequency excitation pulse could provide comparable image quality to the original 3D-BH-PI-MRCP and the 3D-BH-CS-MRCP during a single breath hold (22 seconds), and showed improved SNR and superior visualization of the pancreaticobiliary tree.