Myocardial viability: Breath-hold 3D MR imaging of delayed hyperenhancement with variable sampling in time

被引:47
|
作者
Foo, TKF [1 ]
Stanley, DW
Castillo, E
Rochitte, CE
Wang, Y
Lima, JAC
Bluemke, DA
Wu, KC
机构
[1] GE Med Syst, Appl Sic Lab, Baltimore, MD USA
[2] Johns Hopkins Univ, Dept Radiol, Baltimore, MD 21287 USA
[3] Johns Hopkins Univ, Dept Cardiol, Baltimore, MD 21287 USA
[4] Inst Coracao, Dept Cardiol, Sao Paulo, Brazil
[5] Peoples Hosp, Dept Radiol, Beijing, Peoples R China
关键词
heart; MR; magnetic resonance (MR); contrast enhancement; three-dimensional; myocardium; infarction;
D O I
10.1148/radiol.2303021411
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A method for visualizing myocardial infarction with a three-dimensional (3D) breath-hold gated acquisition was examined. By using variable sampling in time, whole heart coverage with a single volume acquisition was achieved in 24 heart beats. In a study of 35 patients, in whom 3D volume acquisition was compared with a two-dimensional (2D) acquisition, all regions of myocardial infarction were correctly identified at 3D examination. The mean imaging time for 12 section locations was 8.0 minutes +/- 3.0 with a 2D approach compared with 22 seconds +/- 4 with a 3D approach (P < .001). Advantages were also noted for infarct contrast-to-noise ratio: 60 +/- 37 for 3D versus 33 +/- 20 for 2D imaging (P < .001). No significant differences (P > .05) were noted at qualitative assessment of myocardial suppression, endocardial border visualization, respiratory and cardiac motion artifacts, or confidence of transmurality of the infarct. (C) RSNA, 2004.
引用
收藏
页码:845 / 851
页数:7
相关论文
共 50 条
  • [41] MR angiography of internal carotid arteries: Breath-hold Gd-enhanced 3D fast imaging with steady-state precession versus unenhanced 2D and 3D time- of-flight techniques
    Sardanelli, Francesco
    Zandrino, Franco
    Parodi, Roberto Carlo
    De Caro, Giovanni
    Journal of Computer Assisted Tomography, 23 (02): : 208 - 215
  • [42] Single breath-hold 3D contrast-enhanced method for assessment of cardiac function
    Barger, AV
    Grist, TM
    Block, WF
    Mistretta, CA
    MAGNETIC RESONANCE IN MEDICINE, 2000, 44 (06) : 821 - 824
  • [43] Comparison of 3D dense deformable registration methods for breath-hold reproducibility study in radiotherapy
    Boldea, Vlad
    Sarrut, David
    Carrie, Christian
    Progr. Biomed. Opt. Imaging Proc. SPIE, I (222-230):
  • [44] Comparison of 3D dense deformable registration methods for breath-hold reproducibility study in radiotherapy
    Boldea, V
    Sarrut, D
    Carrie, C
    Medical Imaging 2005: Image Processing, Pt 1-3, 2005, 5747 : 222 - 230
  • [45] Time-resolved Contrast-enhanced 3D MR Angiography Using Parallel Imaging with View Sharing (TREAT) - comparing with Breath-hold Single Phase High Spatial 3D Contrast Magnetic Resonance Angiography
    Lu, M.
    Zhao, S.
    Jiang, S.
    Zhang, Y.
    CARDIOLOGY, 2009, 114 : 98 - 99
  • [46] Hepatic lesions: Morphologic and functional characterization with multiphase breath-hold 3D gadolinium-enhanced MR angiography - Initial results
    Hawighorst, H
    Schoenberg, SO
    Knopp, MV
    Essig, M
    Miltner, P
    van Kaick, G
    RADIOLOGY, 1999, 210 (01) : 89 - 96
  • [47] HIGH-RESOLUTION, ELECTROCARDIOGRAM-GATED BREATH-HOLD PULMONARY MR ANGIOGRAPHY WITH ROTATING 3D MULTIPHASIC CINE DISPLAY
    ERDMAN, WA
    CLARKE, GD
    LIPSCOMB, M
    PARKEY, RW
    PESHOCK, RM
    RADIOLOGY, 1992, 185 : 217 - 217
  • [48] Breath-hold 3D MR angiography of the renal vasculature using a contrast-enhanced multiecho gradient-echo technique
    Papachristopoulos, G
    Bis, KG
    Shetty, AN
    Ross, M
    Bagga, H
    Shirkhoda, A
    Laub, G
    INVESTIGATIVE RADIOLOGY, 1999, 34 (12) : 731 - 738
  • [49] Contrast-enhanced breath-hold 3D MR angiography of the thoracic aorta: Utility of EGG-triggered data acquisition
    Rodenwaldt, J
    Kopka, L
    Fischer, U
    Vosshenrich, R
    Funke, M
    Grabbe, EH
    RADIOLOGY, 1998, 209P : 414 - 414
  • [50] Evaluation of a 3D surface imaging system for deep inspiration breath-hold patient positioning and intra-fraction monitoring
    Hamming, Vincent C.
    Visser, Christa
    Batin, Estelle
    McDermott, Leah N.
    Busz, Dianne M.
    Both, Stefan
    Langendijk, Johannes A.
    Sijtsema, Nanna M.
    RADIATION ONCOLOGY, 2019, 14 (1)