A non-enzymatic glucose sensor based on CuO-nanostructure modified carbon ceramic electrode

被引:27
|
作者
Rahim, Abdur [1 ]
Rehman, Zia Ur [2 ]
Mir, Sadullah [2 ]
Muhammad, Nawshad [1 ]
Rehman, Fozia [1 ]
Nawaz, Mian Hasnain [1 ]
Yaqub, Mustansara [1 ]
Siddiqi, Saadat Anwar [1 ]
Chaudhry, Aqif Anwar [1 ]
机构
[1] COMSATS Inst Informat Technol, Interdisciplinary Res Ctr Biomed Mat, Lahore, Pakistan
[2] COMSATS Inst Informat Technol, Dept Chem, Abbottabad, Pakistan
关键词
CuO; Glucose; Non-enzymatic; Nanocomposite; Sol-gel; Carbon ceramic material; SIO2/C ELECTRODE; IN-SITU; NANOPARTICLES; PHTHALOCYANINE; COMPOSITE; GRAPHENE; OXIDASE; FILM; IMMOBILIZATION; NANOCOMPOSITES;
D O I
10.1016/j.molliq.2017.10.087
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Mesoporous silica-graphite composite (SiO2/C-graphite) was synthesized by the sol-gel technique. The surface area (S-BET = 98.93 m(2)/g), pore volume (0.30 cm(3)/g) and pore size (12.16 nm) were characterized by BET. The novelty of this work lays in the fabrication of material in which ceramic material (SiO2/C-graphite) was decorated with copper oxide (CuO) nanostructure. SEM images revealed material compactness without phase segregation and EDX mapping showed a homogenous structure. Pressed disk electrode fabricated with SiO2/C/CuO nanocomposite material was evaluated as an amperometric non-enzymatic glucose sensor in 0.1 M NaOH solution. The linear response range, sensitivity, detection limit, and quantification limit were 0.0220.0 mmol L-1, 0.06 mu mol L-1, 472 mu A mmol(-1) L-1 cm(-2), and 0.76 mmol L-1, respectively. The electrode response time is < 1 s with the addition of 0.02 mmol L-1 glucose. The electrode is chemically stable, exhibits rapid and excellent sensitivity and does not show any interference from coexisting species present in the blood samples. The proposed sensor repeatability was assessed as 1.9% RSD for ten measurements of 13.0 mmol L-1 glucose solution. The sensor tested to ascertain glucose in blood serum showed to be a promising tool for the future evolution of non-enzymatic glucose sensors. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:425 / 431
页数:7
相关论文
共 50 条
  • [1] Non-Enzymatic Glucose Sensor Based on Cu Electrode Modified with CuO Nanoflowers
    Song, Min-Jung
    Lee, Seung-Koo
    Kim, Jong-Hoon
    Lim, Dae-Soon
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2013, 160 (04) : B43 - B46
  • [2] CuO Nanostructure Modified Pencil Graphite Electrode for Non-Enzymatic Detection of Glucose
    Mondal, Shrabani
    Madhuri, Rashmi
    Sharma, Prashant K.
    61ST DAE-SOLID STATE PHYSICS SYMPOSIUM, 2017, 1832
  • [3] An improved sensitivity non-enzymatic glucose sensor based on a CuO nanowire modified Cu electrode
    Zhuang, Zhenjing
    Su, Xiaodong
    Yuan, Hongyan
    Sun, Qun
    Xiao, Dan
    Choi, Martin M. F.
    ANALYST, 2008, 133 (01) : 126 - 132
  • [4] Highly Efficient Non-Enzymatic Glucose Sensor Based on CuO Modified Vertically-Grown ZnO Nanorods on Electrode
    Ahmad, Rafiq
    Tripathy, Nirmalya
    Ahn, Min-Sang
    Bhat, Kiesar Sideeq
    Mahmoudi, Tahmineh
    Wang, Yousheng
    Yoo, Jin-Young
    Kwon, Dae-Wook
    Yang, Hwa-Young
    Hahn, Yoon-Bong
    SCIENTIFIC REPORTS, 2017, 7
  • [5] A Sensitive and Selective Non-Enzymatic Glucose Sensor based on AuNPs/CuO NWs-MoS2 Modified Electrode
    Bao, Jing
    Qi, Yanli
    Huo, Danqun
    Hou, Jingzhou
    Geng, Xintong
    Samalo, Mickey
    Liu, Zishan
    Luo, Huibo
    Yang, Mei
    Hou, Changjun
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (13) : B1179 - B1185
  • [6] Highly Efficient Non-Enzymatic Glucose Sensor Based on CuO Modified Vertically-Grown ZnO Nanorods on Electrode
    Rafiq Ahmad
    Nirmalya Tripathy
    Min-Sang Ahn
    Kiesar Sideeq Bhat
    Tahmineh Mahmoudi
    Yousheng Wang
    Jin-Young Yoo
    Dae-Wook Kwon
    Hwa-Young Yang
    Yoon-Bong Hahn
    Scientific Reports, 7
  • [7] Non-Enzymatic Amperometric Determination of Glucose by CuO Nanobelt Graphene Composite Modified Glassy Carbon Electrode
    Muralikrishna, Sreeramareddygari
    Sureshkumar, Kempahanumakkagari
    Yan, Zhou
    Fernandez, Carlos
    Ramakrishnappa, Thippeswamy
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2015, 26 (08) : 1632 - 1641
  • [8] Carbon nanoparticles based non-enzymatic glucose sensor
    Pulidindi, Indra Neel
    Gedanken, Aharon
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2014, 94 (01) : 28 - 35
  • [9] A Non-Enzymatic Glucose Sensor Based on Ni/MnO2 Nanocomposite Modified Glassy Carbon Electrode
    Wang, Yan
    Bai, Wushuang
    Nie, Fei
    Zheng, Jianbin
    ELECTROANALYSIS, 2015, 27 (10) : 2399 - 2405
  • [10] A Highly Sensitive Non-Enzymatic Glucose Electrochemical Sensor Electrode Material of CuO Nanospheres/Activated Carbon Composites
    Xiang, Dong
    Zhao, Liping
    Wang, Yue
    Li, Xiuze
    Sun, Xu
    Yang, Jiukai
    Liu, Han
    Wan, Cen
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2023, 59 (12) : 1194 - 1205