Non-Enzymatic Amperometric Determination of Glucose by CuO Nanobelt Graphene Composite Modified Glassy Carbon Electrode

被引:29
|
作者
Muralikrishna, Sreeramareddygari [1 ]
Sureshkumar, Kempahanumakkagari [1 ]
Yan, Zhou [2 ]
Fernandez, Carlos [3 ]
Ramakrishnappa, Thippeswamy [1 ]
机构
[1] Jain Univ, Ctr Nano & Mat Sci, Bangalore 560001, Karnataka, India
[2] China Univ Petr East China, Sch Sci, Dept Chem, Qingdao 266580, Peoples R China
[3] Robert Gordon Univ, Sch Pharm & Life Sci, Aberdeen AB10 7GJ, Scotland
关键词
graphene; CuO nanobelts; non-enzymatic sensor; glucose; ELECTROCHEMICAL DETECTION; COPPER NANOPARTICLES; OXIDE; SENSOR; FABRICATION; HYBRID; NANOSTRUCTURES; NANOCOMPOSITES;
D O I
10.5935/0103-5053.20150134
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
We have successfully developed for the first time an electrochemical sensor for glucose by using a simple and effective design of growing CuO nanobelts graphene composites (CuO@G). The as prepared composites were characterized by X-ray diffraction studies (XRD), field emission scanning electron microscopy (FESEM) and transmission electron microscopy (TEM). The prepared composite material exhibits higher electrocatalytic activity for the oxidation of glucose compared to chemically reduced graphene (C rGO) and bare CuO nanobelts. The optimized protocol has linearity with current response for glucose concentration in the range 0.5-6.5 mu mol L-1 and detection limits were found to be 0.05 mu mol L-1 (3 sigma). The method exhibits good reproducibility and selectivity towards glucose in the presence of other electro active compounds that are normally present in blood serum like dopamine, ascorbic acid, uric acid and sodium chloride. The protocol has been successfully applied for glucose determination in clinic human blood serum samples.
引用
收藏
页码:1632 / 1641
页数:10
相关论文
共 50 条
  • [1] Non-enzymatic amperometric glucose sensing on CuO/mesoporous TiO2 modified glassy carbon electrode
    Ali, Muhammad
    Mir, Sadullah
    Ahmed, Safeer
    [J]. RSC ADVANCES, 2023, 13 (37) : 26275 - 26286
  • [2] Electrodeposition of platinum on poly(glutamic acid) modified glassy carbon electrode for non-enzymatic amperometric glucose detection
    Zhou, Xuechou
    Zheng, Xinyu
    Lv, Rixin
    Kong, Dexian
    Li, QingLu
    [J]. ELECTROCHIMICA ACTA, 2013, 107 : 164 - 169
  • [3] Gold nanoparticles directly modified glassy carbon electrode for non-enzymatic detection of glucose
    Chang, Gang
    Shu, Honghui
    Ji, Kai
    Oyama, Munetaka
    Liu, Xiong
    He, Yunbin
    [J]. APPLIED SURFACE SCIENCE, 2014, 288 : 524 - 529
  • [4] Non-enzymatic determination of purine nucleotides using a carbon dot modified glassy carbon electrode
    Karthikeyan, R.
    Nelson, D. James
    John, S. Abraham
    [J]. ANALYTICAL METHODS, 2019, 11 (30) : 3866 - 3873
  • [5] A novel enzymatic glucose biosensor and sensitive non-enzymatic hydrogen peroxide sensor based on graphene and cobalt oxide nanoparticles composite modified glassy carbon electrode
    Karuppiah, Chelladurai
    Palanisamy, Selvakumar
    Chen, Shen-Ming
    Veeramani, Vediyappan
    Periakaruppan, Prakash
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 196 : 450 - 456
  • [6] Non-enzymatic Sensing of Glucose Using Glassy Carbon Electrode Modified with Organometallic Complex of Nickel
    Ciszewski, Aleksander
    Stepniak, Izabela
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (10): : 8298 - 8307
  • [7] A non-enzymatic glucose sensor based on CuO-nanostructure modified carbon ceramic electrode
    Rahim, Abdur
    Rehman, Zia Ur
    Mir, Sadullah
    Muhammad, Nawshad
    Rehman, Fozia
    Nawaz, Mian Hasnain
    Yaqub, Mustansara
    Siddiqi, Saadat Anwar
    Chaudhry, Aqif Anwar
    [J]. JOURNAL OF MOLECULAR LIQUIDS, 2017, 248 : 425 - 431
  • [8] A glassy carbon electrode modified with a nanocomposite consisting of carbon nanohorns and poly(2-aminopyridine) for non-enzymatic amperometric determination of hydrogen peroxide
    Jingchao Chen
    Ping He
    Hongmei Bai
    Hong Lei
    Guangli Zhang
    Faqin Dong
    Yongjun Ma
    [J]. Microchimica Acta, 2016, 183 : 3237 - 3242
  • [9] A glassy carbon electrode modified with a nanocomposite consisting of carbon nanohorns and poly(2-aminopyridine) for non-enzymatic amperometric determination of hydrogen peroxide
    Chen, Jingchao
    He, Ping
    Bai, Hongmei
    Lei, Hong
    Zhang, Guangli
    Dong, Faqin
    Ma, Yongjun
    [J]. MICROCHIMICA ACTA, 2016, 183 (12) : 3237 - 3242
  • [10] Non-enzymatic hydrogen peroxide amperometric sensor based on a glassy carbon electrode modified with an MWCNT/polyaniline composite film and platinum nanoparticles
    Zhong, Huaan
    Yuan, Ruo
    Chai, Yaqin
    Zhang, Yu
    Wang, Chengyan
    Jia, Feng
    [J]. MICROCHIMICA ACTA, 2012, 176 (3-4) : 389 - 395