A non-enzymatic glucose sensor based on CuO-nanostructure modified carbon ceramic electrode

被引:27
|
作者
Rahim, Abdur [1 ]
Rehman, Zia Ur [2 ]
Mir, Sadullah [2 ]
Muhammad, Nawshad [1 ]
Rehman, Fozia [1 ]
Nawaz, Mian Hasnain [1 ]
Yaqub, Mustansara [1 ]
Siddiqi, Saadat Anwar [1 ]
Chaudhry, Aqif Anwar [1 ]
机构
[1] COMSATS Inst Informat Technol, Interdisciplinary Res Ctr Biomed Mat, Lahore, Pakistan
[2] COMSATS Inst Informat Technol, Dept Chem, Abbottabad, Pakistan
关键词
CuO; Glucose; Non-enzymatic; Nanocomposite; Sol-gel; Carbon ceramic material; SIO2/C ELECTRODE; IN-SITU; NANOPARTICLES; PHTHALOCYANINE; COMPOSITE; GRAPHENE; OXIDASE; FILM; IMMOBILIZATION; NANOCOMPOSITES;
D O I
10.1016/j.molliq.2017.10.087
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Mesoporous silica-graphite composite (SiO2/C-graphite) was synthesized by the sol-gel technique. The surface area (S-BET = 98.93 m(2)/g), pore volume (0.30 cm(3)/g) and pore size (12.16 nm) were characterized by BET. The novelty of this work lays in the fabrication of material in which ceramic material (SiO2/C-graphite) was decorated with copper oxide (CuO) nanostructure. SEM images revealed material compactness without phase segregation and EDX mapping showed a homogenous structure. Pressed disk electrode fabricated with SiO2/C/CuO nanocomposite material was evaluated as an amperometric non-enzymatic glucose sensor in 0.1 M NaOH solution. The linear response range, sensitivity, detection limit, and quantification limit were 0.0220.0 mmol L-1, 0.06 mu mol L-1, 472 mu A mmol(-1) L-1 cm(-2), and 0.76 mmol L-1, respectively. The electrode response time is < 1 s with the addition of 0.02 mmol L-1 glucose. The electrode is chemically stable, exhibits rapid and excellent sensitivity and does not show any interference from coexisting species present in the blood samples. The proposed sensor repeatability was assessed as 1.9% RSD for ten measurements of 13.0 mmol L-1 glucose solution. The sensor tested to ascertain glucose in blood serum showed to be a promising tool for the future evolution of non-enzymatic glucose sensors. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:425 / 431
页数:7
相关论文
共 50 条
  • [41] Progress of Enzymatic and Non-Enzymatic Electrochemical Glucose Biosensor Based on Nanomaterial-Modified Electrode
    Nor, Noorhashimah Mohamad
    Ridhuan, Nur Syafinaz
    Razak, Khairunisak Abdul
    BIOSENSORS-BASEL, 2022, 12 (12):
  • [42] Facile fabrication of CuO nanowire modified Cu electrode for non-enzymatic glucose detection with enhanced sensitivity
    Ni, Pengjuan
    Sun, Yujing
    Shi, Yan
    Dai, Haichao
    Hu, Jingting
    Wang, Yilin
    Li, Zhuang
    RSC ADVANCES, 2014, 4 (55) : 28842 - 28847
  • [43] Progress of Enzymatic and Non-Enzymatic Electrochemical Glucose Biosensor Based on Nanomaterial-Modified Electrode
    Mohamad Nor, Noorhashimah
    Ridhuan, Nur Syafinaz
    Abdul Razak, Khairunisak
    Biosensors, 2022, 12 (12):
  • [44] Fabrication of highly sensitive non-enzymatic sensor based on Pt/PVF modified Pt electrode for detection of glucose
    Shveta Malhotra
    Yijun Tang
    Pradeep K. Varshney
    Journal of the Iranian Chemical Society, 2020, 17 : 521 - 531
  • [45] Fabrication of highly sensitive non-enzymatic sensor based on Pt/PVF modified Pt electrode for detection of glucose
    Malhotra, Shveta
    Tang, Yijun
    Varshney, Pradeep K.
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2020, 17 (03) : 521 - 531
  • [46] Electrochemical non-enzymatic glucose sensors based on CuO nanostructures
    Yang, Jiahao
    Yin, Jing
    Xu, Lan
    JOURNAL OF ALLOYS AND COMPOUNDS, 2025, 1010
  • [47] GOLD NANOSTRUCTURE DECORATED 3D POROUS CARBON ARCHITECTURES AS A NON-ENZYMATIC GLUCOSE SENSOR
    Sharma, Deepti
    Lee, Jongmin
    Shin, Heungjoo
    2019 IEEE 32ND INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2019, : 580 - 583
  • [48] Non-enzymatic sensing of glucose using screen-printed electrode modified with novel synthesized CeO2@CuO core shell nanostructure
    Dayakar, T.
    Rao, K. Venkateswara
    Bikshalu, K.
    Malapati, V.
    Sadasivuni, Kishor Kumar
    BIOSENSORS & BIOELECTRONICS, 2018, 111 : 166 - 173
  • [49] Non-enzymatic glucose sensor based on facial hydrothermal synthesized NiO nanosheets loaded on glassy carbon electrode
    Wang, Shutao
    Wang, Cong
    Wei, Guijuan
    Xiao, Huaqing
    An, Ning
    Zhou, Yan
    An, Changhua
    Zhang, Jun
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2016, 509 : 252 - 258
  • [50] A novel enzymatic glucose biosensor and sensitive non-enzymatic hydrogen peroxide sensor based on graphene and cobalt oxide nanoparticles composite modified glassy carbon electrode
    Karuppiah, Chelladurai
    Palanisamy, Selvakumar
    Chen, Shen-Ming
    Veeramani, Vediyappan
    Periakaruppan, Prakash
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 196 : 450 - 456