A non-enzymatic glucose sensor based on CuO-nanostructure modified carbon ceramic electrode

被引:27
|
作者
Rahim, Abdur [1 ]
Rehman, Zia Ur [2 ]
Mir, Sadullah [2 ]
Muhammad, Nawshad [1 ]
Rehman, Fozia [1 ]
Nawaz, Mian Hasnain [1 ]
Yaqub, Mustansara [1 ]
Siddiqi, Saadat Anwar [1 ]
Chaudhry, Aqif Anwar [1 ]
机构
[1] COMSATS Inst Informat Technol, Interdisciplinary Res Ctr Biomed Mat, Lahore, Pakistan
[2] COMSATS Inst Informat Technol, Dept Chem, Abbottabad, Pakistan
关键词
CuO; Glucose; Non-enzymatic; Nanocomposite; Sol-gel; Carbon ceramic material; SIO2/C ELECTRODE; IN-SITU; NANOPARTICLES; PHTHALOCYANINE; COMPOSITE; GRAPHENE; OXIDASE; FILM; IMMOBILIZATION; NANOCOMPOSITES;
D O I
10.1016/j.molliq.2017.10.087
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Mesoporous silica-graphite composite (SiO2/C-graphite) was synthesized by the sol-gel technique. The surface area (S-BET = 98.93 m(2)/g), pore volume (0.30 cm(3)/g) and pore size (12.16 nm) were characterized by BET. The novelty of this work lays in the fabrication of material in which ceramic material (SiO2/C-graphite) was decorated with copper oxide (CuO) nanostructure. SEM images revealed material compactness without phase segregation and EDX mapping showed a homogenous structure. Pressed disk electrode fabricated with SiO2/C/CuO nanocomposite material was evaluated as an amperometric non-enzymatic glucose sensor in 0.1 M NaOH solution. The linear response range, sensitivity, detection limit, and quantification limit were 0.0220.0 mmol L-1, 0.06 mu mol L-1, 472 mu A mmol(-1) L-1 cm(-2), and 0.76 mmol L-1, respectively. The electrode response time is < 1 s with the addition of 0.02 mmol L-1 glucose. The electrode is chemically stable, exhibits rapid and excellent sensitivity and does not show any interference from coexisting species present in the blood samples. The proposed sensor repeatability was assessed as 1.9% RSD for ten measurements of 13.0 mmol L-1 glucose solution. The sensor tested to ascertain glucose in blood serum showed to be a promising tool for the future evolution of non-enzymatic glucose sensors. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:425 / 431
页数:7
相关论文
共 50 条
  • [31] A non-enzymatic glucose sensor based on NiO nanoparticles/functionalized SBA 15/MWCNT-modified carbon paste electrode
    Baghayeri, Mehdi
    Sedrpoushan, Alireza
    Mohammadi, Alireza
    Heidari, Masoud
    IONICS, 2017, 23 (06) : 1553 - 1562
  • [32] A sensitive non-enzymatic glucose sensor in alkaline media based on Cu/MnO2-modified glassy carbon electrode
    Zuchao Meng
    Qinglin Sheng
    Jianbin Zheng
    Journal of the Iranian Chemical Society, 2012, 9 : 1007 - 1014
  • [33] An Improved Sensitivity Non-enzymatic Glucose Sensor Based on a Nano-Gold Modified Ag Electrode
    He Jia-hong
    Xu Qiang
    Gao Zhi-qiang
    Song Zhong-rong
    MICRO-NANO TECHNOLOGY XIII, 2012, 503 : 427 - 431
  • [34] A flexible and disposable hybrid electrode based on Cu nanowires modified graphene transparent electrode for non-enzymatic glucose sensor
    Fan, Zengjie
    Liu, Bin
    Liu, Xiaohong
    Li, Zhangpeng
    Wang, Honggang
    Yang, Shengrong
    Wang, Jinqing
    ELECTROCHIMICA ACTA, 2013, 109 : 602 - 608
  • [35] A novel non-enzymatic glucose sensor based on the modification of carbon paste electrode with CuO nanoflower: Designing the experiments by response surface methodology (RSM)
    Amani-Beni, Zahra
    Nezamzadeh-Ejhieh, Alireza
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2017, 504 : 186 - 196
  • [36] A sensitive AgNPs/CuO nanofibers non-enzymatic glucose sensor based on electrospinning technology
    Zheng, Baozhan
    Liu, Guangyue
    Yao, Aiwen
    Xiao, Yanling
    Du, Juan
    Guo, Yong
    Xiao, Dan
    Hu, Qin
    Choi, Martin M. F.
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 195 : 431 - 438
  • [37] Author Correction: Au nanoparticles modified CuO nanowire electrode based non-enzymatic glucose detection with improved linearity
    Ashwini Kumar Mishra
    Deepak Kumar Jarwal
    Bratindranath Mukherjee
    Amit Kumar
    Smrity Ratan
    Manas Ranjan Tripathy
    Satyabrata Jit
    Scientific Reports, 10
  • [38] A non-enzymatic urea sensor based on the nickel sulfide/graphene oxide modified glassy carbon electrode
    Naik, T. S. Sunil Kumar
    Saravanan, S.
    Saravana, K. N. Sri
    Pratiush, Utkarsh
    Ramamurthy, Praveen C.
    MATERIALS CHEMISTRY AND PHYSICS, 2020, 245
  • [39] Gold nanoparticles directly modified glassy carbon electrode for non-enzymatic detection of glucose
    Chang, Gang
    Shu, Honghui
    Ji, Kai
    Oyama, Munetaka
    Liu, Xiong
    He, Yunbin
    APPLIED SURFACE SCIENCE, 2014, 288 : 524 - 529
  • [40] Enzymatic and non-enzymatic electrochemical glucose sensor based on carbon nano-onions
    Mohapatra, Jeotikanta
    Ananthoju, Balakrishna
    Nair, Vishnu
    Mitra, Arijit
    Bahadur, D.
    Medhekar, N. V.
    Aslam, M.
    APPLIED SURFACE SCIENCE, 2018, 442 : 332 - 341