A non-enzymatic urea sensor based on the nickel sulfide/graphene oxide modified glassy carbon electrode

被引:59
|
作者
Naik, T. S. Sunil Kumar [1 ]
Saravanan, S. [1 ]
Saravana, K. N. Sri [1 ]
Pratiush, Utkarsh [1 ]
Ramamurthy, Praveen C. [1 ]
机构
[1] Indian Inst Sci, Dept Mat Engn, Bangalore 560012, Karnataka, India
关键词
Urea; Nickel sulfide; Graphene oxide; Modified glassy carbon electrode; BIOSENSOR; COMPOSITE; CATALYST; ANODE; ELECTROOXIDATION; NANOCOMPOSITE; POLYANILINE; MECHANISM; FILMS;
D O I
10.1016/j.matchemphys.2020.122798
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Here, a non-enzymatic graphene stabilized nickel sulphide is used for electrochemical based device for detecting urea is carried out. NiS was used as electron distribution on the compound helps in selective interaction with analytes. However, since neat NiS is unstable during the interaction, stabilization of the compound is very critical. Hence, nickel sulfide/graphene oxide (NiS/GO) was synthesized via the superficial hydrothermal method. The synthesized functionalized GO nanoparticles were characterized for size, surface area, and morphology for tuning to the specific application. This compound nickel sulfide/graphene oxide was used to modify glassy carbon electrode (NiS/GO/MGCE). Detection capabilities of this modified electrode to urea in water was evaluated in both electrochemical and electrochemical impedance spectroscopy (EIS) modes. Results suggests that the NiS/GO nanocomposite modified electrode exhibited a very low limit of detection and the electrode process was identified to be diffusion-controlled. In addition, selectivity, interference, long-term stability and practical applicability of the developed sensor were evaluated. Hence, the developed NiS/GO/MGCE displayed excellent electrocatalytic behaviour towards the sensing of urea with good sensitivity, selectivity, and reproducibility.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A reagentless non-enzymatic hydrogen peroxide sensor presented using electrochemically reduced graphene oxide modified glassy carbon electrode
    Mutyala, Sankararao
    Mathiyarasu, Jayaraman
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 69 : 398 - 406
  • [2] Lanthanum Sulfide Nanorods Modified Glassy Carbon Electrode as Non-Enzymatic Biosensor for Xanthine
    Javeed, Zainab
    Ibrahim, Muhammad
    Iqbal, Muhammad Faisal
    Nawaz, Rahat
    Hussain, Dilshad
    Ayub, Muhammad
    Ashiq, Muhammad Naeem
    Majeed, Saadat
    Najam-ul-Haq, Muahmmad
    Fatima, Batool
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2023, 170 (11)
  • [3] A non-enzymatic hydrogen peroxide sensor based on a glassy carbon electrode modified with cuprous oxide and nitrogen-doped graphene in a nafion matrix
    Jiang, Bin-Bin
    Wei, Xian-Wen
    Wu, Fang-Hui
    Wu, Kong-Lin
    Chen, Le
    Yuan, Guo-Zan
    Dong, Chao
    Ye, Yin
    [J]. MICROCHIMICA ACTA, 2014, 181 (11-12) : 1463 - 1470
  • [4] A non-enzymatic hydrogen peroxide sensor based on a glassy carbon electrode modified with cuprous oxide and nitrogen-doped graphene in a nafion matrix
    Bin-Bin Jiang
    Xian-Wen Wei
    Fang-Hui Wu
    Kong-Lin Wu
    Le Chen
    Guo-Zan Yuan
    Chao Dong
    Yin Ye
    [J]. Microchimica Acta, 2014, 181 : 1463 - 1470
  • [5] A novel enzymatic glucose biosensor and sensitive non-enzymatic hydrogen peroxide sensor based on graphene and cobalt oxide nanoparticles composite modified glassy carbon electrode
    Karuppiah, Chelladurai
    Palanisamy, Selvakumar
    Chen, Shen-Ming
    Veeramani, Vediyappan
    Periakaruppan, Prakash
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 196 : 450 - 456
  • [6] Simple non-enzymatic electrochemical sensor for hydrogen peroxide based on nafion/platinum nanoparticles/reduced graphene oxide nanocomposite modified glassy carbon electrode
    Cong Zhang
    Haohai Jiang
    Rui Ma
    Yanyan Zhang
    Qiang Chen
    [J]. Ionics, 2017, 23 : 1309 - 1317
  • [7] Simple non-enzymatic electrochemical sensor for hydrogen peroxide based on nafion/platinum nanoparticles/reduced graphene oxide nanocomposite modified glassy carbon electrode
    Zhang, Cong
    Jiang, Haohai
    Ma, Rui
    Zhang, Yanyan
    Chen, Qiang
    [J]. IONICS, 2017, 23 (05) : 1309 - 1317
  • [8] Graphene oxide/nickel oxide modified glassy carbon electrode for supercapacitor and nonenzymatic glucose sensor
    Yuan, Baiqing
    Xu, Chunying
    Deng, Dehua
    Xing, Yun
    Liu, Lin
    Pang, Huan
    Zhang, Daojun
    [J]. ELECTROCHIMICA ACTA, 2013, 88 : 708 - 712
  • [9] Non-enzymatic Sensing of Glucose Using Glassy Carbon Electrode Modified with Organometallic Complex of Nickel
    Ciszewski, Aleksander
    Stepniak, Izabela
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (10): : 8298 - 8307
  • [10] A Non-Enzymatic Glucose Sensor Based on Ni/MnO2 Nanocomposite Modified Glassy Carbon Electrode
    Wang, Yan
    Bai, Wushuang
    Nie, Fei
    Zheng, Jianbin
    [J]. ELECTROANALYSIS, 2015, 27 (10) : 2399 - 2405