A Non-Enzymatic Glucose Sensor Based on Ni/MnO2 Nanocomposite Modified Glassy Carbon Electrode

被引:35
|
作者
Wang, Yan [1 ,2 ]
Bai, Wushuang [1 ]
Nie, Fei [1 ]
Zheng, Jianbin [1 ]
机构
[1] NW Univ Xian, Inst Analyt Sci, Shaanxi Prov Key Lab Electroanalyt Chem, Xian 710069, Shaanxi, Peoples R China
[2] Xian Med Univ, Coll Pharm, Xian 710021, Shaanxi, Peoples R China
关键词
Non-enzymatic sensor; Glucose; Nickel; Manganese dioxide; MNO2; NANOPARTICLES; ELECTROCATALYTIC OXIDATION; CATALYTIC-OXIDATION; OXIDE NANOPARTICLES; MANGANESE OXIDE; ALKALINE; ELECTROOXIDATION; NANOSPHERES; REDUCTION; MECHANISM;
D O I
10.1002/elan.201500049
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel flower like 3D nickel/manganese dioxide (Ni/MnO2) nanocomposite was synthesized by a kind of simple electrochemical method and the formation mechanism of flower like structure was also researched. In addition, morphology and composition of the nanocomposite were characterized by scanning electron microscope (SEM), transmission electron microscopy (TEM), and X-ray photoelectron spectroscopy (XPS). Then the Ni/MnO2 nanocomposites were applied to fabricate electrochemical non-enzymatic glucose sensor. The electrochemical investigation for the sensor indicated that it possessed an excellent electrocatalytic property for glucose, and could applied to the quantification of glucose with a linear range from 2.5x10(-7) to 3.5x10(-3)M, a sensitivity of 1.04mAmM(-1)cm(-2), and a detection limit of 1x10(-7)M (S/N=3). The proposed sensor also presented attractive features such as interference-free, and long-term stability. The present study provided a general platform for the one-step synthesis of nanomaterials with novel structure and can be extended to other optical, electronic and magnetic nanocompounds.
引用
收藏
页码:2399 / 2405
页数:7
相关论文
共 50 条
  • [1] A sensitive non-enzymatic glucose sensor in alkaline media based on Cu/MnO2-modified glassy carbon electrode
    Meng, Zuchao
    Sheng, Qinglin
    Zheng, Jianbin
    [J]. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2012, 9 (06) : 1007 - 1014
  • [2] A sensitive non-enzymatic glucose sensor in alkaline media based on Cu/MnO2-modified glassy carbon electrode
    Zuchao Meng
    Qinglin Sheng
    Jianbin Zheng
    [J]. Journal of the Iranian Chemical Society, 2012, 9 : 1007 - 1014
  • [3] A novel non-enzymatic glucose electrochemical sensor based on CNF@Ni-Co layered double hydroxide modified glassy carbon electrode
    Fu, Rong
    Lu, Youlan
    Ding, Yaping
    Li, Li
    Ren, Zhongming
    Si, Xiaojing
    Wu, Qingsheng
    [J]. MICROCHEMICAL JOURNAL, 2019, 150
  • [4] Gold nanoparticles directly modified glassy carbon electrode for non-enzymatic detection of glucose
    Chang, Gang
    Shu, Honghui
    Ji, Kai
    Oyama, Munetaka
    Liu, Xiong
    He, Yunbin
    [J]. APPLIED SURFACE SCIENCE, 2014, 288 : 524 - 529
  • [5] Utilization of a MnO2/polythiophene/rGO nanocomposite modified glassy carbon electrode as an electrochemical sensor for methyl parathion
    T. Ramachandran
    V. Violet Dhayabaran
    [J]. Journal of Materials Science: Materials in Electronics, 2019, 30 : 12315 - 12327
  • [6] Utilization of a MnO2/polythiophene/rGO nanocomposite modified glassy carbon electrode as an electrochemical sensor for methyl parathion
    Ramachandran, T.
    Dhayabaran, V. Violet
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2019, 30 (13) : 12315 - 12327
  • [7] A non-enzymatic urea sensor based on the nickel sulfide/graphene oxide modified glassy carbon electrode
    Naik, T. S. Sunil Kumar
    Saravanan, S.
    Saravana, K. N. Sri
    Pratiush, Utkarsh
    Ramamurthy, Praveen C.
    [J]. MATERIALS CHEMISTRY AND PHYSICS, 2020, 245
  • [8] A non-enzymatic glucose sensor based on CuO-nanostructure modified carbon ceramic electrode
    Rahim, Abdur
    Rehman, Zia Ur
    Mir, Sadullah
    Muhammad, Nawshad
    Rehman, Fozia
    Nawaz, Mian Hasnain
    Yaqub, Mustansara
    Siddiqi, Saadat Anwar
    Chaudhry, Aqif Anwar
    [J]. JOURNAL OF MOLECULAR LIQUIDS, 2017, 248 : 425 - 431
  • [9] Non-enzymatic hydrogen peroxide sensor based on MnO2-ordered mesoporous carbon composite modified electrode
    Luo, Liqiang
    Li, Fang
    Zhu, Limei
    Zhang, Zhao
    Ding, Yaping
    Deng, Dongmei
    [J]. ELECTROCHIMICA ACTA, 2012, 77 : 179 - 183
  • [10] Non-enzymatic Sensing of Glucose Using Glassy Carbon Electrode Modified with Organometallic Complex of Nickel
    Ciszewski, Aleksander
    Stepniak, Izabela
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (10): : 8298 - 8307