Comparison of the ImmuView and the BinaxNOW antigen tests in detection of Streptococcus pneumoniae and Legionella pneumophila in urine

被引:18
|
作者
Athlin, S. [1 ]
Iversen, A. [2 ,3 ]
Ozenci, V. [2 ,4 ]
机构
[1] Orebro Univ, Fac Med & Hlth, Dept Infect Dis, S-70185 Orebro, Sweden
[2] Karolinska Inst, Div Clin Microbiol, Dept Lab Med, Stockholm, Sweden
[3] Karolinska Univ Hosp, Dept Clin Microbiol, Stockholm, Sweden
[4] Karolinska Inst, Karolinska Univ Hosp, Dept Clin Microbiol F 72, SE-14186 Stockholm, Sweden
关键词
COMMUNITY-ACQUIRED PNEUMONIA; ENZYME-IMMUNOASSAY EIA; LEGIONNAIRES-DISEASE; IMMUNOCHROMATOGRAPHIC ASSAY; ANTIMICROBIAL-THERAPY; HOSPITALIZED-PATIENTS; SAMPLES; METAANALYSIS; MANAGEMENT; DIAGNOSIS;
D O I
10.1007/s10096-017-3016-6
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
The use of urinary antigen tests (UATs) may provide early etiology in pneumonia, and facilitates rapid and directed antibiotic treatment. In this study, we evaluated the novel lateral flow ImmuView Streptococcus pneumoniae and Legionella pneumophila UAT, which detects pneumococcal and L. pneumophila serogroup 1 antigens in a combined test. We compared the ImmuView UAT with the BinaxNOW S. pneumoniae UAT and the BinaxNOW L. pneumophila UAT in 147 patients with pneumococcal bacteremia (n = 48), non-pneumococcal non-Legionella bacteremia (n = 93) and Legionella infections in the lower airways (L. pneumophila, n = 5; L. bozemanii, n = 1). In three cases, the ImmuView test was invalid before and after boiling while the BinaxNOW tests were valid in all cases. In 144 cases, the three UATs demonstrated a very good inter-assay agreement for detection of pneumococcal antigen (kappa = 0.86) and L. pneumophila antigen (kappa = 1.00). The ImmuView and BinaxNOW S. pneumoniae tests had similar sensitivities (62% vs 60%; p = ns) in 48 cases with pneumococcal bacteremia and both tests had specificities of 97% in 96 cases with non-pneumococcal infections. Furthermore, the ImmuView and BinaxNOW L. pneumophila tests were positive for Legionella antigen in five patients with confirmed L. pneumophila serogroup 1 infections, and negative in all non-L. pneumophila cases. The ImmuView and BinaxNOW tests performed similarly when evaluated on urine samples from bacteremic and non-bacteremic patients with identified etiology.
引用
收藏
页码:1933 / 1938
页数:6
相关论文
共 50 条
  • [21] Detection of Legionella pneumophila antigen in urine samples:: Recognition of serogroups and monoclonal subgroups
    Helbig, JH
    Uldum, SA
    Lück, PC
    Harrison, TG
    LEGIONELLA, 2002, : 204 - 206
  • [22] EVALUATION OF THE LEGIONELLA V-TEST CORIS○ IN COMPARISON TO THE BINAXNOW TO DETECT THE LEGIONELLA SEROGROUP 1 ANTIGEN IN URINE SAMPLES
    De Witte, Evy
    Loens, Katherine
    Lammens, Christine
    Almirall, Jordi
    Goossens, Herman
    Even, Margareta
    ACTA CLINICA BELGICA, 2012, 67 (01): : 68 - 68
  • [23] Comparison of five commercial assays for the detection of Legionella pneumophila antigens in urine
    de Ory, Fernando
    Minguito, Teodora
    ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2009, 27 (02): : 81 - 84
  • [24] Detection of Legionella pneumophila serogroup 1 antigen in nonconcentrated urine and urine concentrated by selective ultrafiltration
    Dominguez, JA
    Manterola, JM
    Blavia, R
    Sopena, N
    Belda, FJ
    Padilla, E
    Gimenez, M
    Sabria, M
    Morera, J
    Ausina, V
    JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (09) : 2334 - 2336
  • [25] Evaluation of the Oxoid Xpect Legionella Test Kit for Detection of Legionella pneumophila Serogroup 1 Antigen in Urine
    Diederen, B. M. W.
    Bruin, J. P.
    Scopes, E.
    Peeters, M. F.
    IJzerman, E. P. F.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (07) : 2272 - 2274
  • [26] Legionella pneumophila LPS to evaluate urinary antigen tests
    Ranc, Anne-Gaelle
    Carpentier, Margot
    Beraud, Laetitia
    Descours, Ghislaine
    Ginevra, Christophe
    Maisonneuve, Elodie
    Verdon, Julien
    Berjeaud, Jean-Marc
    Lina, Gerard
    Jarraud, Sophie
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2017, 89 (02) : 89 - 91
  • [27] Streptococcus pneumoniae and Legionella pneumophila pneumonia in HIV-infected patients
    Pedro-Botet, M. Luisa
    Sopena, Nieves
    Garcia-Cruz, Arantxa
    Mateu, Lourdes
    Garcia-Nunez, Marian
    Rey-Joly, Celestino
    Sabria, Miquel
    SCANDINAVIAN JOURNAL OF INFECTIOUS DISEASES, 2007, 39 (02) : 122 - 128
  • [28] DETECTION OF LEGIONELLA-PNEUMOPHILA ANTIGEN IN URINE BY ENZYME-LINKED IMMUNOSPECIFIC ASSAY
    BERDAL, BP
    FARSHY, CE
    FEELEY, JC
    JOURNAL OF CLINICAL MICROBIOLOGY, 1979, 9 (05) : 575 - 578
  • [29] Evaluation of the SAS Legionella Test, a new immunochromatographic assay for the detection of Legionella pneumophila serogroup 1 antigen in urine
    Diederen, B. M. W.
    Peeters, M. F.
    CLINICAL MICROBIOLOGY AND INFECTION, 2007, 13 (01) : 86 - 88
  • [30] Detection of streptococcus pneumoniae antigen by a rapid immunochromatographic assay in urine samples
    Domínguez, J
    Galí, N
    Blanco, S
    Pedroso, P
    Prat, C
    Matas, L
    Ausina, V
    CHEST, 2001, 119 (01) : 243 - 249