摘要
The use of urinary antigen tests (UATs) may provide early etiology in pneumonia, and facilitates rapid and directed antibiotic treatment. In this study, we evaluated the novel lateral flow ImmuView Streptococcus pneumoniae and Legionella pneumophila UAT, which detects pneumococcal and L. pneumophila serogroup 1 antigens in a combined test. We compared the ImmuView UAT with the BinaxNOW S. pneumoniae UAT and the BinaxNOW L. pneumophila UAT in 147 patients with pneumococcal bacteremia (n = 48), non-pneumococcal non-Legionella bacteremia (n = 93) and Legionella infections in the lower airways (L. pneumophila, n = 5; L. bozemanii, n = 1). In three cases, the ImmuView test was invalid before and after boiling while the BinaxNOW tests were valid in all cases. In 144 cases, the three UATs demonstrated a very good inter-assay agreement for detection of pneumococcal antigen (kappa = 0.86) and L. pneumophila antigen (kappa = 1.00). The ImmuView and BinaxNOW S. pneumoniae tests had similar sensitivities (62% vs 60%; p = ns) in 48 cases with pneumococcal bacteremia and both tests had specificities of 97% in 96 cases with non-pneumococcal infections. Furthermore, the ImmuView and BinaxNOW L. pneumophila tests were positive for Legionella antigen in five patients with confirmed L. pneumophila serogroup 1 infections, and negative in all non-L. pneumophila cases. The ImmuView and BinaxNOW tests performed similarly when evaluated on urine samples from bacteremic and non-bacteremic patients with identified etiology.
引用
下载
收藏
页码:1933 / 1938
页数:6
相关论文
共 50 条
  • [11] Evaluation of Legionella V-TesT for the detection of Legionella pneumophila antigen in urine samples
    J. P. Bruin
    M. F. Peeters
    E. P. F. IJzerman
    B. M. W. Diederen
    European Journal of Clinical Microbiology & Infectious Diseases, 2010, 29 : 899 - 900
  • [12] The Uni-Gold™ Streptococcus pneumoniae urinary antigen test: an interassay comparison with the BinaxNOW® Streptococcus pneumoniae test on consecutive urine samples and evaluation on patients with bacteremia
    S. Athlin
    O. Altun
    H. B. Eriksen
    V. Özenci
    K. Strålin
    European Journal of Clinical Microbiology & Infectious Diseases, 2015, 34 : 1583 - 1588
  • [13] Evaluation of Legionella V-TesT for the detection of Legionella pneumophila antigen in urine samples
    Bruin, J. P.
    Peeters, M. F.
    IJzerman, E. P. F.
    Diederen, B. M. W.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2010, 29 (07) : 899 - 900
  • [14] Immunochromatic kits Xpect Legionella and BinaxNOW Legionella for detection of Legionella pneumophila urinary antigen have low sensitivities for the diagnosis of Legionnaires' disease
    Svarrer, Christina Wiid
    Lueck, Christian
    Elverdal, Pernille Landsbo
    Uldum, Soren A.
    JOURNAL OF MEDICAL MICROBIOLOGY, 2012, 61 (02) : 213 - 217
  • [15] Comparison between the STANDARD™ F S. Pneumoniae Ag FIA and BinaxNOW S. Pneumoniae Antigen Card for Detection of Streptococcus Pneumoniae Urinary Antigen
    Yu, Hui-Jin
    Kim, Tae Yeul
    Shim, Hyang Jin
    Yun, Sun Ae
    Kim, Ji-Youn
    Kang, On Kyun
    Huh, Hee Jae
    Lee, Nam Yong
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2022, 104 (01)
  • [16] Evaluation of a new ELISA (Bartels) for detection of Legionella pneumophila antigen in urine
    de Ory, F
    ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2002, 20 (03): : 106 - 109
  • [17] Interpretation of diagnostic tests: Comparison of five commercial tests for the diagnosis of Legionella pneumophila in urine
    Campillo-Soto, Alvaro
    del Rio-Medel, Leticia
    Liron-Ruiz, Ramon
    Gervasio Martin-Lorenzo, Juan
    ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2009, 27 (09): : 554 - 555
  • [18] Ruling out False-Positive Urinary Legionella pneumophila Serogroup 1 and Streptococcus pneumoniae Antigen Test Results by Heating Urine
    Pontoizeau, C.
    Dangers, L.
    Jarlier, V.
    Luyt, C. E.
    Guiller, E.
    Fievet, M. H.
    Lecsoe-Bornet, M.
    Aubry, A.
    Brossier, F.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2014, 52 (12) : 4347 - 4349
  • [19] Comparative evaluation of the novel IMMUNOCATCHTM Streptococcus pneumoniae (EIKEN CHEMICAL CO., LTD) test with the Uni-GoldTM Streptococcus pneumoniae assay and the BinaxNOW® Streptococcus pneumoniae antigen card for the detection of pneumococcal capsular antigen in urine samples
    Congestri, F.
    Morotti, M.
    Vicari, R.
    Pedna, M. F.
    Sparacino, M.
    Torri, A.
    Bertini, S.
    Fantini, M.
    Sambri, V.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2020, 39 (04) : 749 - 751
  • [20] Comparative evaluation of the novel IMMUNOCATCHTM Streptococcus pneumoniae (EIKEN CHEMICAL CO., LTD) test with the Uni-GoldTM Streptococcus pneumoniae assay and the BinaxNOW® Streptococcus pneumoniae antigen card for the detection of pneumococcal capsular antigen in urine samples
    F. Congestrì
    M. Morotti
    R. Vicari
    M. F. Pedna
    M. Sparacino
    A. Torri
    S. Bertini
    M. Fantini
    V. Sambri
    European Journal of Clinical Microbiology & Infectious Diseases, 2020, 39 : 749 - 751