COMMUNITY-ACQUIRED PNEUMONIA; ENZYME-IMMUNOASSAY EIA; LEGIONNAIRES-DISEASE; IMMUNOCHROMATOGRAPHIC ASSAY; ANTIMICROBIAL-THERAPY; HOSPITALIZED-PATIENTS; SAMPLES; METAANALYSIS; MANAGEMENT; DIAGNOSIS;
D O I
10.1007/s10096-017-3016-6
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
The use of urinary antigen tests (UATs) may provide early etiology in pneumonia, and facilitates rapid and directed antibiotic treatment. In this study, we evaluated the novel lateral flow ImmuView Streptococcus pneumoniae and Legionella pneumophila UAT, which detects pneumococcal and L. pneumophila serogroup 1 antigens in a combined test. We compared the ImmuView UAT with the BinaxNOW S. pneumoniae UAT and the BinaxNOW L. pneumophila UAT in 147 patients with pneumococcal bacteremia (n = 48), non-pneumococcal non-Legionella bacteremia (n = 93) and Legionella infections in the lower airways (L. pneumophila, n = 5; L. bozemanii, n = 1). In three cases, the ImmuView test was invalid before and after boiling while the BinaxNOW tests were valid in all cases. In 144 cases, the three UATs demonstrated a very good inter-assay agreement for detection of pneumococcal antigen (kappa = 0.86) and L. pneumophila antigen (kappa = 1.00). The ImmuView and BinaxNOW S. pneumoniae tests had similar sensitivities (62% vs 60%; p = ns) in 48 cases with pneumococcal bacteremia and both tests had specificities of 97% in 96 cases with non-pneumococcal infections. Furthermore, the ImmuView and BinaxNOW L. pneumophila tests were positive for Legionella antigen in five patients with confirmed L. pneumophila serogroup 1 infections, and negative in all non-L. pneumophila cases. The ImmuView and BinaxNOW tests performed similarly when evaluated on urine samples from bacteremic and non-bacteremic patients with identified etiology.
引用
收藏
页码:1933 / 1938
页数:6
相关论文
共 50 条
  • [31] Evaluation of three Immunochromatographic Assays for Detection of Legionella pneumophila serogroup 1 Antigen in Urine Samples
    Munoz, M. J.
    Martinez Toldos, M. C.
    Yaguee, G.
    Segovia, M.
    REVISTA ESPANOLA DE QUIMIOTERAPIA, 2009, 22 (04) : 207 - 209
  • [32] DETECTION OF LEGIONELLA-PNEUMOPHILA ANTIGEN BY ELISA IN URINE OF EXPERIMENTALLY INFECTED GUINEA-PIGS
    LEBRUN, L
    TRAM, C
    LAPIERRE, F
    GRANGEOTKEROS, L
    PILLOT, J
    ANNALES DE MICROBIOLOGIE, 1983, A134 (02): : 155 - 161
  • [33] Evaluation of Meridian TRU Legionella®, a new rapid test for detection of Legionella pneumophila serogroup 1 antigen in urine samples
    J. P. Bruin
    B. M. W. Diederen
    European Journal of Clinical Microbiology & Infectious Diseases, 2013, 32 : 333 - 334
  • [34] SINGLE TUBE REAL TIME PCR FOR DETECTION OF STREPTOCOCCUS PNEUMONIAE, MYCOPLASMA PNEUMONIAE, CHLAMYDOPHILA PNEUMONIAE AND LEGIONELLA PNEUMOPHILA FROM CLINICAL SAMPLES OF CAP
    Nomanpour, Bizhan
    Ghodousi, Arash
    Babaei, Toraj
    Jafari, Siroos
    Feizabadi, Mohammad Mehdi
    ACTA MICROBIOLOGICA ET IMMUNOLOGICA HUNGARICA, 2012, 59 (02) : 171 - 184
  • [35] Evaluation of two new immunochromatographic assays (Rapid U Legionella antigen test and SD Bioline Legionella antigen test) for detection of Legionella pneumophila serogroup 1 antigen in urine
    Diederen, Bram M. W.
    Peeters, Marcel F.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2006, 44 (08) : 2991 - 2993
  • [36] Comparison of Legionella K-set® and BinaxNOW® Legionella for diagnosing Legionnaires' disease on concentrated urine samples
    Souche, Aubin
    Descours, Ghislaine
    Ranc, Anne-Gaelle
    Lina, Gerard
    Jarraud, Sophie
    Beraud, Laetitia
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2020, 39 (09) : 1641 - 1644
  • [37] Comparison of Legionella K-set® and BinaxNOW® Legionella for diagnosing Legionnaires’ disease on concentrated urine samples
    Aubin Souche
    Ghislaine Descours
    Anne-Gaëlle Ranc
    Gérard Lina
    Sophie Jarraud
    Laetitia Beraud
    European Journal of Clinical Microbiology & Infectious Diseases, 2020, 39 : 1641 - 1644
  • [38] Comparison of radioimmunoassay and enzyme immunoassay kits for detection of Legionella pneumophila serogroup 1 antigen in both concentrated and nonconcentrated urine samples
    Dominguez, JA
    Matas, L
    Manterola, JM
    Blavia, R
    Sopena, N
    Belda, FJ
    Padilla, E
    Gimenez, M
    Sabria, M
    Morera, J
    Ausina, V
    JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (06) : 1627 - 1629
  • [39] Evaluation of the Sofia Streptococcus pneumoniae FIA test for the detection of S. pneumoniae antigen in urine
    Euser, Sjoerd M.
    Badoux, Paul
    Kracht-Kosten, Lianne
    Yzerman, Ed P. F.
    JOURNAL OF MEDICAL MICROBIOLOGY, 2018, 67 (12) : 1743 - 1746
  • [40] Evaluation of two commercial tests for detection of Legionella pneumophila and Mycoplasma pneumoniae (Duplica, Euroclone) in clinical specimens
    Lueck, C.
    Helbig, J. H.
    Hochauf, K.
    Jacobs, E.
    Dumke, R.
    INTERNATIONAL JOURNAL OF MEDICAL MICROBIOLOGY, 2009, 299 : 40 - 40