Uniform prostate imaging and spectroscopy at 7 T: comparison between a microstrip array and an endorectal coil

被引:29
|
作者
van den Bergen, Bob [1 ]
Klomp, Dennis W. J. [2 ]
Raaijmakers, Alexander J. E. [1 ]
de Castro, Catalina Arteaga [2 ]
Boer, Vincent O. [2 ]
Kroeze, Hugo [2 ]
Luijten, Peter R. [2 ]
Lagendijk, Jan J. W. [1 ]
van den Berg, Cornelis A. T. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiotherapy, NL-3508 GA Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Radiol, NL-3508 GA Utrecht, Netherlands
关键词
7T MRI; prostate imaging; RF safety; endorectal coil; microstrip array; INTRINSIC THERMAL-CONDUCTIVITY; SAR;
D O I
10.1002/nbm.1599
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An endorectal coil and an eight-element microstrip array were compared for prostate imaging at 7 T. An extensive radiofrequency safety assessment was performed with the use of finite difference time domain simulations to determine safe scan parameters. These simulations showed that the endorectal coil can deliver substantially more B-1(+) to the prostate than can the microstrip array within the specific absorption rate safety guidelines. However, the B-1(+) field of the endorectal coil is very inhomogeneous, which makes the use of adiabatic pulses compulsory for T-1- or T-2-weighted imaging. As a consequence, a full prostate examination is only possible in a feasible amount of time when the microstrip array is used for T-1-and T-2-weighted imaging, whereas the endorectal coil is required for spectroscopic imaging. The pulse parameters were optimised within the specific absorption rate guidelines and thereafter used to provide a good illustration of the possibilities of prostate imaging at 7 T. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:358 / 365
页数:8
相关论文
共 50 条
  • [31] A novel endorectal RF coil for high resolution MRI and spectroscopy of the prostate
    ZHANG Hongjie 1
    2. Navy General Hospital
    3. Peking University First Hospital
    Progress in Natural Science, 2005, (05) : 472 - 476
  • [32] Shielded Microstrip Array for 7T Human MR Imaging
    Wu, Bing
    Wang, Chunsheng
    Kelley, Douglas A. C.
    Xu, Duan
    Vigneron, Daniel B.
    Nelson, Sarah J.
    Zhang, Xiaoliang
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (01) : 179 - 184
  • [33] Endorectal coil magnetic resonance imaging and clinicopathologic findings in T1c adenocarcinoma of the prostate
    Bernstein, MR
    Cangiano, T
    D'Amico, A
    Chittams, J
    Hardy, C
    Whittington, RD
    Tomaszewski, JE
    Schnall, MD
    Wein, AJ
    Malkowicz, SB
    UROLOGIC ONCOLOGY, 2000, 5 (03): : 104 - 107
  • [34] A simple method for the correction of endorectal surface coil inhomogeneity in prostate imaging
    Liney, GP
    Turnbull, LW
    Knowles, AJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (04): : 994 - 997
  • [35] Correlation of endorectal coil magnetic resonance imaging of the prostate with pathologic stage
    Stephen A. Brassell
    William R. Krueger
    Jong-Ho Choi
    John A. Taylor
    World Journal of Urology, 2004, 22 : 289 - 292
  • [36] Correlation of endorectal coil magnetic resonance imaging of the prostate with pathologic stage
    Brassell, SA
    Krueger, WR
    Choi, JH
    Taylor, JA
    WORLD JOURNAL OF UROLOGY, 2004, 22 (04) : 289 - 292
  • [37] A Novel Three-Channel Endorectal Coil for Prostate Magnetic Resonance Imaging at 3T
    Mo, Zhiguang
    Zhang, Xiaoping
    Liang, Huageng
    Chen, Qiaoyan
    Tie, Changjun
    Xiao, Wen
    Cao, Qi
    Liu, Chenchen
    Zou, Chao
    Wan, Liwen
    Zhang, Xiaoliang
    Li, Ye
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2023, 70 (12) : 3381 - 3388
  • [38] Multiparametric MR imaging of the prostate at 1.5-T without endorectal coil using an 8 channel pelvic phased array: Is it still a viable option?
    Pierro, A.
    Di Marco, M.
    Piacentini, M.
    Astore, C.
    Maselli, G.
    Guerriero, M.
    Di Lallo, A.
    Sallustio, G.
    Marcellino, A.
    Cilla, S.
    RADIOGRAPHY, 2021, 27 (02) : 459 - 463
  • [39] Detection of extracapsular extension of prostate carcinoma with endorectal and phased-array coil MR imaging: Multivariate feature analysis
    Yu, KK
    Hricak, H
    Alagappan, R
    Chernoff, DM
    Bacchetti, P
    Zaloudek, CJ
    RADIOLOGY, 1997, 202 (03) : 697 - 702
  • [40] Three-dimensional proton MR spectroscopy of human prostate at 3 T without endorectal coil: Feasibility
    Scheenen, Tom W. J.
    Heijmink, Stijn W. T. P. J.
    Roell, Stefan A.
    Hulsbergen-Van de Kaa, Christina A.
    Knipscheer, Ben C.
    Witjes, J. Alfred
    Barentsz, Jelle O.
    Heerschap, Arend
    RADIOLOGY, 2007, 245 (02) : 507 - 516