Dimensional Accuracy of Pickup Implant Impression: An In Vitro Comparison of Novel Modular Versus Standard Custom Trays

被引:0
|
作者
Simeone, Piero
Valentini, Pier Paolo [1 ]
Pizzoferrato, Roberto [1 ]
Scudieri, Folco [1 ]
机构
[1] Univ Roma Tor Vergata, Dept Mech Engn, Rome, Italy
关键词
acrylic resin; direct implant impression; implant connection; individual tray; pickup impression technique; splinted implant impression; OSSEOINTEGRATED IMPLANTS; RESTORATIONS; SYSTEM; FIT;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this in vitro study was to compare the dimensional accuracy of the pickup impression technique using a modular individual tray (MIT) and using a standard individual tray (ST) for multiple internal-connection implants. The roles of both materials and geometric misfits were considered. Materials and Methods: First, because the MIT relies on the stiffness and elasticity of acrylic resin material, a preliminary investigation of the resin volume contraction during curing and polymerization was done. Then, two sets of specimens were tested to compare the accuracy of the MIT (test group) to that of the ST (control group). The linear and angular displacements of the transfer copings were measured and compared during three different stages of the impression procedure. Experimental measurements were performed with a computerized coordinate measuring machine. Results: The curing dynamic of the acrylic resin was strongly dependent on the physical properties of the acrylic material and the powder/liquid ratio. Specifically, an increase in the powder/liquid ratio accelerated resin polymerization (curing time decreases by 70%) and reduced the final volume contraction by 45%. However, the total shrinkage never exceeded the elastic limits of the material; hence, it did not affect the coping's stability. In the test group, linear errors were reduced by 55% and angular errors were reduced by 65%. Conclusions: Linear and angular displacements of the transfer copings were significantly reduced with the MIT technique, which led to higher dimensional accuracy versus the ST group. The MIT approach, in combination with a thin and uniform amount of acrylic resin in the pickup impression technique, showed no significant permanent distortions in multiple misalignment internal-connection implants compared to the ST technique. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:538-546
引用
收藏
页码:538 / 546
页数:9
相关论文
共 36 条
  • [1] Accuracy of open tray implant impressions: an in vitro comparison of stock versus custom trays
    Burns, J
    Palmer, R
    Howe, L
    Wilson, R
    JOURNAL OF PROSTHETIC DENTISTRY, 2003, 89 (03): : 250 - 255
  • [2] Need for a reliable alternative to custom-made Implant Impression trays: An in vitro study comparing accuracy of custom trays versus specialized aluminum stock tray
    Goel, Mukti
    Dhawan, Pankaj
    Tandan, Piyush
    Madhukar, Pankaj
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2018, 18 (03): : 271 - 276
  • [3] IMPRESSION ACCURACY - A COMPARISON OF DUAL-ARCH AND CUSTOM TRAYS
    SCHWARTZ, RS
    DAVIS, RD
    JOURNAL OF DENTAL RESEARCH, 1990, 69 : 304 - 304
  • [4] Comparison of accuracy of hexed and nonhexed pickup impression copings in a multiple variable impression setup for recording multiple straight and angulated implant positions: An in vitro study
    Kaur, Tavleen
    Singla, Shefali
    Kumar, Lalit
    THE JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2023, 23 (01) : 21 - 29
  • [5] Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression: An in vitro study
    Lee, Heeje
    Ercoli, Carlo
    Funkenbusch, Paul D.
    Feng, Changyong
    JOURNAL OF PROSTHETIC DENTISTRY, 2008, 99 (02): : 107 - 113
  • [6] Chairside 3-D printed impression trays: a new approach to increase the accuracy of conventional implant impression taking? An in vitro study
    Alexander Schmidt
    Cara Berschin
    Bernd Wöstmann
    Maximiliane Amelie Schlenz
    International Journal of Implant Dentistry, 9
  • [7] Chairside 3-D printed impression trays: a new approach to increase the accuracy of conventional implant impression taking? An in vitro study
    Schmidt, Alexander
    Berschin, Cara
    Woestmann, Bernd
    Schlenz, Maximiliane Amelie
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2023, 9 (01)
  • [8] In Vitro Comparison of the Accuracy of Conventional Impression and Four Intraoral Scanners in Four Different Implant Impression Scenarios
    Alpkilic, Dilara Seyma
    Deger, Sabire Isler
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (01) : 39 - 48
  • [9] The effect of different implant impression splinting techniques and time on the dimensional accuracy: An in vitro study
    Rutkunas, V.
    Bilius, V.
    Simonaitis, T.
    Auskalnis, L.
    Jurgilevicius, J.
    Akulauskas, M.
    JOURNAL OF DENTISTRY, 2022, 126
  • [10] Effect of 2 Impression Techniques on the Dimensional Accuracy of Working Implant Prosthesis Models: An In Vitro Study
    Calesini, Gaetano
    Zarone, Fernando
    Sorrentino, Roberto
    Micarelli, Costanza
    Fabianelli, Andrea
    Papacchini, Federica
    Gherlone, Enrico
    JOURNAL OF CRANIOFACIAL SURGERY, 2014, 25 (03) : 822 - 827