Dimensional Accuracy of Pickup Implant Impression: An In Vitro Comparison of Novel Modular Versus Standard Custom Trays

被引:0
|
作者
Simeone, Piero
Valentini, Pier Paolo [1 ]
Pizzoferrato, Roberto [1 ]
Scudieri, Folco [1 ]
机构
[1] Univ Roma Tor Vergata, Dept Mech Engn, Rome, Italy
关键词
acrylic resin; direct implant impression; implant connection; individual tray; pickup impression technique; splinted implant impression; OSSEOINTEGRATED IMPLANTS; RESTORATIONS; SYSTEM; FIT;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this in vitro study was to compare the dimensional accuracy of the pickup impression technique using a modular individual tray (MIT) and using a standard individual tray (ST) for multiple internal-connection implants. The roles of both materials and geometric misfits were considered. Materials and Methods: First, because the MIT relies on the stiffness and elasticity of acrylic resin material, a preliminary investigation of the resin volume contraction during curing and polymerization was done. Then, two sets of specimens were tested to compare the accuracy of the MIT (test group) to that of the ST (control group). The linear and angular displacements of the transfer copings were measured and compared during three different stages of the impression procedure. Experimental measurements were performed with a computerized coordinate measuring machine. Results: The curing dynamic of the acrylic resin was strongly dependent on the physical properties of the acrylic material and the powder/liquid ratio. Specifically, an increase in the powder/liquid ratio accelerated resin polymerization (curing time decreases by 70%) and reduced the final volume contraction by 45%. However, the total shrinkage never exceeded the elastic limits of the material; hence, it did not affect the coping's stability. In the test group, linear errors were reduced by 55% and angular errors were reduced by 65%. Conclusions: Linear and angular displacements of the transfer copings were significantly reduced with the MIT technique, which led to higher dimensional accuracy versus the ST group. The MIT approach, in combination with a thin and uniform amount of acrylic resin in the pickup impression technique, showed no significant permanent distortions in multiple misalignment internal-connection implants compared to the ST technique. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:538-546
引用
收藏
页码:538 / 546
页数:9
相关论文
共 36 条
  • [11] A comparison of the dimensional accuracy of the splinted and unsplinted impression techniques for the Bone-Lock implant system
    Burawi, G
    Houston, F
    Byrne, D
    Claffey, N
    JOURNAL OF PROSTHETIC DENTISTRY, 1997, 77 (01): : 68 - 75
  • [12] Accuracy of Digital vs Conventional Implant Impression Approach: A Three-Dimensional Comparative In Vitro Analysis
    Basaki, Kinga
    Alkumru, Hasan
    De Souza, Grace
    Finer, Yoav
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (04) : 792 - 799
  • [13] Dimensional Accuracy of Novel Vinyl Polysiloxane Compared with Polyether Impression Materials: An In Vitro Study
    Waldecker, Moritz
    Rues, Stefan
    Rammelsberg, Peter
    Boemicke, Wolfgang
    MATERIALS, 2024, 17 (17)
  • [14] Accuracy of Multi-implant Impressions Using 3D-Printing Custom Trays and Splinting Versus Conventional Techniques for Complete Arches
    Liu, Yanping
    Di, Ping
    Zhao, Yijiao
    Hao, Qiang
    Tian, Jiehua
    Cui, Hongyan
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (04) : 1007 - 1014
  • [15] Accuracy of edentulous full-arch implant impression: An in vitro comparison between conventional impression, intraoral scan with and without splinting, and photogrammetry
    Cheng, Jing
    Zhang, Haidong
    Liu, Hailin
    Li, Junying
    Wang, Hom-Lay
    Tao, Xian
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (05) : 560 - 572
  • [16] Accuracy of intraoral optical scan versus stereophotogrammetry for complete-arch digital implant impression: An in vitro study
    Pozzi, Alessandro
    Agliardi, Enrico
    Lio, Fabrizio
    Nagy, Katalin
    Nardi, Alessandra
    Arcuri, Lorenzo
    JOURNAL OF PROSTHODONTIC RESEARCH, 2024, 68 (01) : 172 - 180
  • [17] Evaluation and Comparison of Accuracy of Complete Arch Digital and Conventional Implant Impression as Influenced by the Use of a 3D Printed Modular Splint -An In-Vitro Study
    Pol, Bhushan S.
    Sabane, Ajay V.
    Jadhav, Rajashree D.
    Kadam, Pankaj P.
    Gachake, Arti R.
    Kalsekar, Bhagyashree G.
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 (SUPPL 4) : S3764 - S3767
  • [18] Assessment of Effect of Different Sterilization Agents on Dimensional Accuracy of Different Impression Materials in Implant Prosthesis - An In vitro Study
    Kavita, Kumari
    Reddy, K. R. Parameshwar
    Reddy, K. R. Maheshwar
    Kumar, Swatantra
    Pandey, Gyanendra
    Singh, Revati
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2021, 13 (06): : S1620 - S1623
  • [19] Three-Dimensional Accuracy of Digital Impression versus Conventional Method: Effect of Implant Angulation and Connection Type
    Alikhasi, Marzieh
    Siadat, Hakime
    Nasirpour, Alireza
    Hasanzade, Mahya
    INTERNATIONAL JOURNAL OF DENTISTRY, 2018, 2018
  • [20] Effect of different impression coping and scan body designs on the accuracy of conventional versus digital implant impressions: An in vitro study
    Alkindi, Shaikha
    Hamdoon, Zaid
    Aziz, Ahmed M.