Dimensional Accuracy of Pickup Implant Impression: An In Vitro Comparison of Novel Modular Versus Standard Custom Trays

被引:0
|
作者
Simeone, Piero
Valentini, Pier Paolo [1 ]
Pizzoferrato, Roberto [1 ]
Scudieri, Folco [1 ]
机构
[1] Univ Roma Tor Vergata, Dept Mech Engn, Rome, Italy
关键词
acrylic resin; direct implant impression; implant connection; individual tray; pickup impression technique; splinted implant impression; OSSEOINTEGRATED IMPLANTS; RESTORATIONS; SYSTEM; FIT;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this in vitro study was to compare the dimensional accuracy of the pickup impression technique using a modular individual tray (MIT) and using a standard individual tray (ST) for multiple internal-connection implants. The roles of both materials and geometric misfits were considered. Materials and Methods: First, because the MIT relies on the stiffness and elasticity of acrylic resin material, a preliminary investigation of the resin volume contraction during curing and polymerization was done. Then, two sets of specimens were tested to compare the accuracy of the MIT (test group) to that of the ST (control group). The linear and angular displacements of the transfer copings were measured and compared during three different stages of the impression procedure. Experimental measurements were performed with a computerized coordinate measuring machine. Results: The curing dynamic of the acrylic resin was strongly dependent on the physical properties of the acrylic material and the powder/liquid ratio. Specifically, an increase in the powder/liquid ratio accelerated resin polymerization (curing time decreases by 70%) and reduced the final volume contraction by 45%. However, the total shrinkage never exceeded the elastic limits of the material; hence, it did not affect the coping's stability. In the test group, linear errors were reduced by 55% and angular errors were reduced by 65%. Conclusions: Linear and angular displacements of the transfer copings were significantly reduced with the MIT technique, which led to higher dimensional accuracy versus the ST group. The MIT approach, in combination with a thin and uniform amount of acrylic resin in the pickup impression technique, showed no significant permanent distortions in multiple misalignment internal-connection implants compared to the ST technique. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:538-546
引用
收藏
页码:538 / 546
页数:9
相关论文
共 36 条
  • [21] Effects of Impression Coping Design, Impression Technique, and Dental Undercuts on the Accuracy of Implant Impressions Assessed by 3-Dimensional Optical Scanning: An In Vitro Study
    Sabouhi, Mahmoud
    Bajoghli, Farshad
    Dakhilalian, Mansour
    Beygi, Ali
    Abolhasani, Majid
    IMPLANT DENTISTRY, 2016, 25 (02) : 238 - 246
  • [22] Finish line distinctness and accuracy in 7 intraoral scanners versus conventional impression: an in vitro descriptive comparison
    Robert Nedelcu
    Pontus Olsson
    Ingela Nyström
    Andreas Thor
    BMC Oral Health, 18
  • [23] Finish line distinctness and accuracy in 7 intraoral scanners versus conventional impression: an in vitro descriptive comparison
    Nedelcu, Robert
    Olsson, Pontus
    Nystrom, Ingela
    Thor, Andreas
    BMC ORAL HEALTH, 2018, 18
  • [24] Comparison of the Accuracy of a Mounting Fixture for Dental Implants for Implant Position Transfer and Open-Tray Implant Level Impression-An In Vitro Study
    Becker, Alexander
    Dirksen, Dieter
    Runte, Christoph
    DENTISTRY JOURNAL, 2023, 11 (09)
  • [25] Comparison of accuracy/dimensional stability of high-rigid vinyl polysiloxane, polyvinyl siloxane, and polyether impression materials in full arch implant–supported prosthesis: In vitro study
    Kurella K.S.
    Thiyaneswaran N.
    Abhinav R.P.
    Journal of Long-Term Effects of Medical Implants, 2020, 30 (03): : 179 - 186
  • [26] Comparison the accuracy of a novel implant robot surgery and dynamic navigation system in dental implant surgery: an in vitro pilot study
    Chen, Jianping
    Bai, Xiaolei
    Ding, Yude
    Shen, Liheng
    Sun, Xin
    Cao, Ruijue
    Yang, Fan
    Wang, Linhong
    BMC ORAL HEALTH, 2023, 23 (01)
  • [27] Comparison the accuracy of a novel implant robot surgery and dynamic navigation system in dental implant surgery: an in vitro pilot study
    Jianping Chen
    Xiaolei Bai
    Yude Ding
    Liheng Shen
    Xin Sun
    Ruijue Cao
    Fan Yang
    Linhong Wang
    BMC Oral Health, 23
  • [28] Accuracy of Selective Laser Melted Bar Retaining Mandibular Implant-Assisted Overdenture: An In Vitro Comparison of Different Impression Materials and Techniques
    El-Asfahani, Iman A.
    Ramdan, Amr S.
    Agamy, Emad M. T. M.
    JOURNAL OF ORAL IMPLANTOLOGY, 2023, 49 (06) : 590 - 598
  • [29] Comparison of Different Intraoral Scanners With Prefabricated Aid on Accuracy and Framework Passive Fit of Digital Complete-Arch Implant Impression: An In Vitro Study
    Fu, Xiao-Jiao
    Liu, Min
    Shi, Jun-Yu
    Deng, Ke
    Lai, Hong-Chang
    Gu, Wen
    Zhang, Xiao-Meng
    CLINICAL ORAL IMPLANTS RESEARCH, 2025, 36 (01) : 17 - 27
  • [30] Improved scanning accuracy with newly designed scan bodies: An in vitro study comparing digital versus conventional impression techniques for complete-arch implant rehabilitation
    Huang, Ruoxuan
    Liu, Yuanxiang
    Huang, Baoxin
    Zhang, Chaobiao
    Chen, Zhuofan
    Li, Zhipeng
    CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (07) : 625 - 633