Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression: An in vitro study

被引:71
|
作者
Lee, Heeje [1 ]
Ercoli, Carlo
Funkenbusch, Paul D.
Feng, Changyong
机构
[1] Louisiana State Univ, Sch Dent, New Orleans, LA 70119 USA
[2] Univ Rochester, Eastman Dent Ctr, Rochester, NY USA
[3] Univ Rochester, Sch Engn & Appl Sci, Rochester, NY USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2008年 / 99卷 / 02期
关键词
D O I
10.1016/S0022-3913(08)60026-8
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. In some instances, an implant needs to be placed deep subgingivally, which may result in a less accurate impression of the implant. Purpose. The purpose of this study was to evaluate the effect of subgingival depth of implant placement on the accuracy of implant impressions. Material and methods. A stone master model was fabricated with 5 Implant analogs (RN synOcta analog), embedded parallel to each other, at the center (E) and the 4 corners (A, 13, C, and D). The vertical position of the shoulders of the implants was intentionally different among the implants: A and E were flush with the top surface of the model; B was 2 mm below, and C and D were 4 mm below the surface. The horizontal distances of implants A, 13, C, and D from E were measured with a measuring microscope. A cross-shaped metal measuring bar was then fabricated and connected to E, with the arms of the casting designed to be 2 mm above the top surface of the model and incorporating a reference mark. With the measuring bar connected to E, the vertical distances from the apical surface of A, B, C, and D to the measuring reference marks were measured with a digital micrometer. The body of the impression coping for implant D was modified by adding 4 mm of additional impression coping, while standard impression copings were used for all other implants. Open tray impressions were made using medium-body polyether material (Impregum Penta) or a combination of putty and light-body vinyl polysiloxane (VPS) material (Elite HD+) (n=15). Then casts were poured with type IV dental stone. The vertical and horizontal distances of the casts were measured with the methods outlined above for the master model. The distortion values that were determined as differences between the measurements of the master model and those of the casts were collected for statistical analysis. Two-way and 1-way repeated measures ANOVA followed by Tukey's HSD test were performed to compare the distortion values (alpha=.05). Results. For vertical measurements, 2-way repeated measures ANOVA showed no significant depth (P=36), material (P=.24), or interaction effects (P=.06). However, it showed significant depth effect for horizontal measurements (P=.01). Within the polyether group, 1-way repeated measures ANOVA showed significant differences in horizontal measurements among the implants with different depths (P=.03). The post hoc Tukey's test showed that the impression of 4-mm-deep implants with normal impression copings (C) was significantly less accurate than impressions of 0-mm-deep implants (A) (P=.02). Within the VPS group, there was no significant difference among the implants with different depths (P=.09). Conclusions. There was no effect of implant depth on the accuracy of the VPS group. However, for the polyether group, the impression of an implant placed 4 mm subgingivally showed a greater horizontal distortion compared to an implant placed more coronally. Adding a 4-mm extension to the retentive part of the impression coping eliminated this difference.
引用
收藏
页码:107 / 113
页数:7
相关论文
共 50 条
  • [1] Effect of impression coping and implant angulation on the accuracy of implant impressions: an in vitro study
    Jo, Si-Hoon
    Kim, Kyoung-Ii
    Seo, Jae-Min
    Song, Kwang-Yeob
    Park, Ju-Mi
    Ahn, Seung-Geun
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2010, 2 (04): : 128 - 133
  • [2] The effect of different implant impression splinting techniques and time on the dimensional accuracy: An in vitro study
    Rutkunas, V.
    Bilius, V.
    Simonaitis, T.
    Auskalnis, L.
    Jurgilevicius, J.
    Akulauskas, M.
    [J]. JOURNAL OF DENTISTRY, 2022, 126
  • [3] Evaluation of the effect of implant angulations and impression techniques on implant cast accuracy u An in vitro study
    Arora, Aman
    Upadhyaya, Viram
    Parashar, Kirti R.
    Malik, Divya
    [J]. JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2019, 19 (02): : 149 - 158
  • [4] Effect of 2 Impression Techniques on the Dimensional Accuracy of Working Implant Prosthesis Models: An In Vitro Study
    Calesini, Gaetano
    Zarone, Fernando
    Sorrentino, Roberto
    Micarelli, Costanza
    Fabianelli, Andrea
    Papacchini, Federica
    Gherlone, Enrico
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2014, 25 (03) : 822 - 827
  • [5] Accuracy of Interchangeable Implant Impression Systems: An In Vitro Pilot Study
    Aldosari, Abdullah M. AlFarraj
    AlBaker, Abdulaziz M.
    AlShihri, Abdulmonem A.
    AlJadeed, Majid I.
    AlBwardi, Loay A.
    Anil, Sukumaran
    [J]. IMPLANT DENTISTRY, 2015, 24 (03) : 317 - 322
  • [6] Assessment of Effect of Different Sterilization Agents on Dimensional Accuracy of Different Impression Materials in Implant Prosthesis - An In vitro Study
    Kavita, Kumari
    Reddy, K. R. Parameshwar
    Reddy, K. R. Maheshwar
    Kumar, Swatantra
    Pandey, Gyanendra
    Singh, Revati
    [J]. JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2021, 13 (06): : S1620 - S1623
  • [7] The Effect of Implant Connection Length on the Dimensional Impression Accuracy of Inclined Implants
    Ehsani, Sara
    Siadat, Hakimeh
    Alikhasi, Marzieh
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (06) : E315 - E320
  • [8] In vitro method for test and measure the accuracy of implant impression
    Caramelo, F. J.
    Brito, P.
    Santos, J.
    Carvalho, A.
    Veiga, G.
    Vasconcelos, B.
    Pires, J. N.
    Botelho, M. F.
    [J]. TECHNOLOGY AND MEDICAL SCIENCES - TMSI 2010, 2011, : 329 - 331
  • [9] A prospective clinical study on implant impression accuracy
    Motaz Osman
    Hassan Ziada
    Ahmed Suliman
    Neamat Hassan Abubakr
    [J]. International Journal of Implant Dentistry, 5
  • [10] A prospective clinical study on implant impression accuracy
    Osman, Motaz
    Ziada, Hassan
    Suliman, Ahmed
    Abubakr, Neamat Hassan
    [J]. INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2019, 5 (01)