The effect of different implant impression splinting techniques and time on the dimensional accuracy: An in vitro study

被引:8
|
作者
Rutkunas, V. [1 ]
Bilius, V. [1 ]
Simonaitis, T. [2 ]
Auskalnis, L. [3 ]
Jurgilevicius, J. [4 ]
Akulauskas, M. [5 ]
机构
[1] Vilnius Univ, Inst Odontol, Fac Med, Dept Prosthodont, Vilnius, Lithuania
[2] Digitorum LAB, Vilnius, Lithuania
[3] Prodentum Clin, Vilnius, Lithuania
[4] Taikos Odontologijos Klin, Taikos Str 21-3, LT-91141 Klaipeda, Lithuania
[5] Kaunas Univ Technol, Biomed Engn Inst, Kaunas, Lithuania
关键词
Implant impression; Accuracy; Splinting; 3D printing; Digital dentistry; POLYMERIZATION SHRINKAGE; DIGITAL EVALUATION; PROSTHESES; ARCH; FIT;
D O I
10.1016/j.jdent.2022.104267
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: Splinting of impression copings is generally recommended for complex implant-supported restorations. It can also be used in the digital workflow when a control model is needed to improve the fit of the prosthesis. However, there is a lack of knowledge on how dimensional accuracy is affected by different splinting techniques and time factors. Objectives: To evaluate the time factor on the dimensional stability of different implant impression splinting techniques used in the conventional and digital workflow. Materials and methods: Ten pairs of implant analogs were fixed to a stainless steel bar. Modified impression copings were connected to the analogs and eight splinting strategies evaluated (n=10): (1) type I impression plaster (PLA), (2) autopolymerizing acrylic resin, cut and rejoin technique (PTR), (3) light-cured acrylic resin, cut and rejoin technique (ILC), (4) light-cured acrylic resin, no cutting and rejoining (ILN), (5) VPS bite registration material (SBR), (6) bis-acryl bite registration material (LXB), (7) bis-acryl composite resin (PTP), (8) 3D printed splint (3DP). In each group, the position of modified impression copings was scanned with a laboratory scanner at different time points: (1) unsplinted impression copings (baseline), (2) 2 h after splinting, (3) 24 h after splinting. Modified impression coping design allowed using metrology software to measure and compare distance, vertical, angle and rotational deviations between impression copings. Results: All types of splints showed dimensional deviations. After 2 h of splinting, the lowest distance deviation was recorded in PTR (15.4 +/- 6.15 mu m), vertical deviation - in ILC (19.2 +/- 27.37 mu m), angle deviation - in ILC (0.08 +/- 0.1.), rotation - in LXB (0.2 +/- 0.24.) groups. Comparing results 2 and 24 h after connection of impression copings, statistically significant deviations in the distance were recorded in groups PLA (-5.6 +/- 5.95 mu m), PTR (5.5 +/- 7.01 mu m), ILN (19.2 +/- 14.26 mu m), PTP (23.8 +/- 12.55 mu m). Conclusions: The best dimensional accuracy was observed in the ILC group, followed by PTR and 3DP groups. Clinical significance: Proper selection of splinting technique and polymerization time can increase the accuracy of conventional or digital impressions. Splinting techniques with rigid materials, proper polymerization and compensating for material shrinkage seem to produce the best results.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Effect of Splinting in Accuracy of Two Implant Impression Techniques
    de Avila, Erica Dorigatti
    Moraes, Fernanda de Matos
    Castanharo, Sabrina Maria
    Del'Acqua, Marcelo Antonialli
    Mollo, Francisco de Assis, Jr.
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (06) : 633 - 639
  • [2] Accuracy of implant impression splinted techniques: Effect of splinting material
    Assif, D
    Nissan, J
    Varsano, I
    Singer, A
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1999, 14 (06) : 885 - 888
  • [3] Effect of 2 Impression Techniques on the Dimensional Accuracy of Working Implant Prosthesis Models: An In Vitro Study
    Calesini, Gaetano
    Zarone, Fernando
    Sorrentino, Roberto
    Micarelli, Costanza
    Fabianelli, Andrea
    Papacchini, Federica
    Gherlone, Enrico
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2014, 25 (03) : 822 - 827
  • [4] Accuracy of different impression techniques for multiunit implant restoration: A qualitative in vitro study
    Ismail, Ibrahim Ahmed
    Alhajj, Mohammed Nasser
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (06): : E1 - E5
  • [5] Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression: An in vitro study
    Lee, Heeje
    Ercoli, Carlo
    Funkenbusch, Paul D.
    Feng, Changyong
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2008, 99 (02): : 107 - 113
  • [6] Evaluation of Splinting Implant Impression Techniques: Two Dimensional Analyses
    Tarib, N. A.
    Seong, T. W.
    Chuen, K. M.
    Kun, M. S.
    Ahmad, M.
    Kamarudin, K. H.
    [J]. EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2012, 20 (01): : 35 - 39
  • [7] Assessment of Effect of Different Sterilization Agents on Dimensional Accuracy of Different Impression Materials in Implant Prosthesis - An In vitro Study
    Kavita, Kumari
    Reddy, K. R. Parameshwar
    Reddy, K. R. Maheshwar
    Kumar, Swatantra
    Pandey, Gyanendra
    Singh, Revati
    [J]. JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2021, 13 (06): : S1620 - S1623
  • [8] Cast accuracy obtained from different impression techniques at different implant angulations (in vitro study)
    Elshenawy, Enas A.
    Alam-Eldein, Ahmed M.
    Abd Elfatah, Fadel A.
    [J]. INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2018, 4
  • [9] Cast accuracy obtained from different impression techniques at different implant angulations (in vitro study)
    Enas A. Elshenawy
    Ahmed M. Alam-Eldein
    Fadel A. Abd Elfatah
    [J]. International Journal of Implant Dentistry, 4
  • [10] Evaluation of the effect of implant angulations and impression techniques on implant cast accuracy u An in vitro study
    Arora, Aman
    Upadhyaya, Viram
    Parashar, Kirti R.
    Malik, Divya