A novel selective-excitation RF pulse for magnetic resonance imaging

被引:3
|
作者
Liu Ying [1 ]
Li Jianqi [1 ]
Li Gengying [1 ]
机构
[1] E China Normal Univ, Dept Phys, Shanghai Key Lab Funct Magnet Resonance Imaging, Shanghai 200062, Peoples R China
关键词
MRI; selective excitation; P/N pulse;
D O I
10.1007/s10334-008-0111-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Object A selective-excitation radiofrequency (RF) pulse that uses hard pulses composed of a sequence of composite pulses with positive and negative phases (P/N pulse) is proposed herein. Because the amplitude of the RF signal is unchanged during the excitation, RF amplification can be accomplished using a nonlinear RF power amplifier (i.e., class C or D type). Materials and methods In this article, Fourier series have been first used to analyze the equivalence between the proposed P/N pulse and the conventional soft pulse on selective excitation. Subsequently, computer simulations based on density-matrix theory are used to compare the excitation profiles of both the soft and the P/N pulses. Results The excitation profiles of the P/N pulses have been measured experimentally through a home-built 0.3-T magnetic resonance imaging (MRI) system. In addition, several slices of images have been obtained as proofs by using the multislice two-dimensional spin echo sequence through replacement of the conventional soft pulse by the proposed P/N pulse. Conclusion Because the perfect selectivity of the proposed P/N pulse, it can be used for imaging studies to improve the efficiency of amplification at the lowest cost.
引用
收藏
页码:199 / 205
页数:7
相关论文
共 50 条
  • [31] Magnetic Resonance RF Pulse Design by Optimal Control With Physical Constraints
    Rund, Armin
    Aigner, Christoph Stefan
    Kunisch, Karl
    Stollberger, Rudolf
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (02) : 461 - 472
  • [32] Selective magnetic resonance signal suppression by colored Frank excitation
    Goerges, Alexander
    Benders, Stefan
    Greferath, Marcus
    Kueppers, Markus
    Adams, Michael
    Bluemich, Bernhard
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2020, 317
  • [33] SELECTIVE-EXCITATION STUDY OF COLLISIONAL EXCITATION TRANSFER FOR HELIUM 31,3P AND D STATES
    YASUMARU, N
    OKU, S
    FUJIMOTO, T
    FUKUDA, K
    [J]. JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1980, 49 (02) : 696 - 703
  • [34] Sparsity-enforced slice-selective MRI RF excitation pulse design
    Zelinski, Adam C.
    Wald, Lawrence L.
    Setsompop, Kawin
    Goyal, Vivek K.
    Adalsteinsson, Elfar
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (09) : 1213 - 1229
  • [35] Iterative RF pulse design for multidimensional, small-tip-angle selective excitation
    Yip, CY
    Fessler, JA
    Douglas, CN
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (04) : 908 - 917
  • [36] COMPARATIVE-STUDY OF PULSE SEQUENCES FOR SELECTIVE EXCITATION IN NMR IMAGING
    FRAHM, J
    HANICKE, W
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1984, 60 (02) : 320 - 332
  • [37] SMOOTH SADDLE RF COIL FOR MAGNETIC-RESONANCE-IMAGING
    VASLOW, DF
    [J]. MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 1991, 4 (11) : 501 - 506
  • [38] SPARSE MAGNETIC RESONANCE IMAGING USING TAGGING RF PULSES
    Singh, Vimal
    Tewfik, Ahmed H.
    [J]. 2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 302 - 305
  • [39] HYBRID RF COIL FOR NUCLEAR-MAGNETIC-RESONANCE IMAGING
    DELUCA, F
    LUZZI, M
    CRESCENZI, A
    DESIMONE, BC
    CAMPANELLA, R
    CASIERI, C
    MARAVIGLIA, B
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1986, 67 (01) : 7 - 13
  • [40] Analysis of Coupling and Loading in RF Coils for Magnetic Resonance Imaging
    Omar, Abbas
    [J]. 2018 18TH INTERNATIONAL SYMPOSIUM ON ANTENNA TECHNOLOGY AND APPLIED ELECTROMAGNETICS (ANTEM 2018), 2018,