Iterative RF pulse design for multidimensional, small-tip-angle selective excitation

被引:71
|
作者
Yip, CY
Fessler, JA
Douglas, CN
机构
[1] Univ Michigan, Dept Elect & Comp Sci, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
关键词
iterative pulse design; small tip angle; selective excitation; excitation k-space; constrained minimization;
D O I
10.1002/mrm.20631
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The excitation k-space perspective on small-tip-angle selective excitation has facilitated RF pulse designs in a range of MR applications. In this paper, k-space-based design of multidimensional RF pulses is formulated as a quadratic optimization problem, and solved efficiently by the iterative conjugate-gradient (CG) algorithm. Compared to conventional design approaches, such as the conjugate-phase (CP) method, the new design approach is beneficial in several regards. It generally produces more accurate excitation patterns. The improvement is particularly significant when k-space is undersampled, and it can potentially shorten pulse lengths. A prominent improvement in accuracy is also observed when large off -resonance gradients are present. A further boost in excitation accuracy can be accomplished in regions of interest (ROIs) if they are specified together with "don't-care" regions. The density compensation function (DCF) is no longer required. In addition, regularization techniques allow control over integrated and peak pulse power.
引用
收藏
页码:908 / 917
页数:10
相关论文
共 49 条
  • [1] Robust RF shimming and small-tip-angle multispoke pulse design with finite-difference regularization
    Paez, Adrian
    Gu, Chunming
    Cao, Zhipeng
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (03) : 1472 - 1481
  • [2] A K-SPACE ANALYSIS OF SMALL-TIP-ANGLE EXCITATION
    PAULY, J
    NISHIMURA, D
    MACOVSKI, A
    JOURNAL OF MAGNETIC RESONANCE, 1989, 81 (01): : 43 - 56
  • [3] Small-tip-angle spokes pulse design using interleaved greedy and local optimization methods
    Grissom, William A.
    Khalighi, Mohammad-Mehdi
    Sacolick, Laura I.
    Rutt, Brian K.
    Vogel, Mika W.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (05) : 1553 - 1562
  • [4] Fast Large-Tip-Angle Multidimensional and Parallel RF Pulse Design in MRI
    Grissom, William A.
    Xu, Dan
    Kerr, Adam B.
    Fessler, Jeffrey A.
    Noll, Douglas C.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (10) : 1548 - 1559
  • [5] Additive angle method for fast large-tip-angle RF pulse design in parallel excitation
    Grissom, William A.
    Yip, Chun-Yu
    Wright, Steven M.
    Fessler, Jeffrey A.
    Noll, Douglas C.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (04) : 779 - 787
  • [6] Application of the small-tip-angle approximation in the toggling frame for the design of analytic robust pulses in quantum control
    Van Damme, L.
    Sugny, D.
    Glaser, S. J.
    PHYSICAL REVIEW A, 2021, 104 (04)
  • [7] Joint Design of Excitation k-Space Trajectory and RF Pulse for Small-Tip 3D Tailored Excitation in MRI
    Hao, Sun
    Fessler, Jeffrey A.
    Noll, Douglas C.
    Nielsen, Jon-Fredrik
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (02) : 468 - 479
  • [8] Sparsity in MRI RF excitation pulse design
    Zelinski, Adam C.
    Goyal, Vivek K.
    Adalsteinsson, Elfar
    Wald, Lawrence L.
    2008 42ND ANNUAL CONFERENCE ON INFORMATION SCIENCES AND SYSTEMS, VOLS 1-3, 2008, : 252 - +
  • [9] Sparsity-enforced slice-selective MRI RF excitation pulse design
    Zelinski, Adam C.
    Wald, Lawrence L.
    Setsompop, Kawin
    Goyal, Vivek K.
    Adalsteinsson, Elfar
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (09) : 1213 - 1229
  • [10] RF PULSE SHAPES FOR SELECTIVE EXCITATION IN NMR IMAGING
    SMITH, MR
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1985, 4 (02) : 79 - 83