Iterative RF pulse design for multidimensional, small-tip-angle selective excitation

被引:71
|
作者
Yip, CY
Fessler, JA
Douglas, CN
机构
[1] Univ Michigan, Dept Elect & Comp Sci, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
关键词
iterative pulse design; small tip angle; selective excitation; excitation k-space; constrained minimization;
D O I
10.1002/mrm.20631
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The excitation k-space perspective on small-tip-angle selective excitation has facilitated RF pulse designs in a range of MR applications. In this paper, k-space-based design of multidimensional RF pulses is formulated as a quadratic optimization problem, and solved efficiently by the iterative conjugate-gradient (CG) algorithm. Compared to conventional design approaches, such as the conjugate-phase (CP) method, the new design approach is beneficial in several regards. It generally produces more accurate excitation patterns. The improvement is particularly significant when k-space is undersampled, and it can potentially shorten pulse lengths. A prominent improvement in accuracy is also observed when large off -resonance gradients are present. A further boost in excitation accuracy can be accomplished in regions of interest (ROIs) if they are specified together with "don't-care" regions. The density compensation function (DCF) is no longer required. In addition, regularization techniques allow control over integrated and peak pulse power.
引用
收藏
页码:908 / 917
页数:10
相关论文
共 49 条
  • [41] An improved algorithm for design of broadband excitation, inversion, and mixing pulse sequences by iterative optimization of phases: TOPS-2
    Jacob, Justin
    Shetty, Tejas
    Khaneja, Navin
    JOURNAL OF MAGNETIC RESONANCE, 2023, 353
  • [42] |B1+|-selective excitation pulse design using the Shinnar-Le Roux algorithm
    Grissom, William A. p
    Cao, Zhipeng
    Does, Mark D.
    JOURNAL OF MAGNETIC RESONANCE, 2014, 242 : 189 - 196
  • [43] Quick Reduction of Specific Absorption Rate Constraints in Parallel RF Excitation Pulse Design by Maximum Volume Inscribed Ellipsoids
    Majewski, Kurt
    CONCEPTS IN MAGNETIC RESONANCE PART A, 2019, 2019
  • [44] Factors influencing flip angle mapping in MRI:: RF pulse shape, slice-select gradients, off-resonance excitation, and Bo inhomogeneities
    Wang, Jinghua
    Mao, Weihua
    Qiu, Maolin
    Smith, Michael B.
    Constable, R. Todd
    MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (02) : 463 - 468
  • [45] Small tip angle three-dimensional tailored radiofrequency slab-select pulse for reduced B1 inhomogeneity at 3 T
    Saekho, S
    Boada, FE
    Noll, DC
    Stenger, VA
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (02) : 479 - 484
  • [46] Rapid Inner-Volume Imaging in the Steady-State With 3D Selective Excitation and Small-Tip Fast Recovery Imaging
    Sun, Hao
    Fessler, Jeffrey A.
    Noll, Douglas C.
    Nielsen, Jon-Fredrik
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (04) : 1217 - 1223
  • [47] In vivo demonstration of whole-brain multislice multispoke parallel transmit radiofrequency pulse design in the small and large flip angle regimes at 7 Tesla
    Gras, Vincent
    Vignaud, Alexandre
    Amadon, Alexis
    Mauconduit, Franck
    Le Bihan, Denis
    Boulant, Nicolas
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (03) : 1009 - 1019
  • [48] Local Specific Absorption Rate (SAR), Global SAR, Transmitter Power, and Excitation Accuracy Trade-Offs in Low Flip-Angle Parallel Transmit Pulse Design
    Guerin, Bastien
    Gebhardt, Matthias
    Cauley, Steven
    Adalsteinsson, Elfar
    Wald, Lawrence L.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (04) : 1446 - 1457
  • [49] Parallel-transmission spatial spectral pulse design with local specific absorption rate control: Demonstration for robust uniform water-selective excitation in the human brain at 7 T
    Shao, Xin
    Zhang, Zhe
    Ma, Xiaodong
    Liu, Fan
    Guo, Hua
    Ugurbil, Kamil
    Wu, Xiaoping
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (03) : 1238 - 1255