Iterative RF pulse design for multidimensional, small-tip-angle selective excitation

被引:71
|
作者
Yip, CY
Fessler, JA
Douglas, CN
机构
[1] Univ Michigan, Dept Elect & Comp Sci, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
关键词
iterative pulse design; small tip angle; selective excitation; excitation k-space; constrained minimization;
D O I
10.1002/mrm.20631
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The excitation k-space perspective on small-tip-angle selective excitation has facilitated RF pulse designs in a range of MR applications. In this paper, k-space-based design of multidimensional RF pulses is formulated as a quadratic optimization problem, and solved efficiently by the iterative conjugate-gradient (CG) algorithm. Compared to conventional design approaches, such as the conjugate-phase (CP) method, the new design approach is beneficial in several regards. It generally produces more accurate excitation patterns. The improvement is particularly significant when k-space is undersampled, and it can potentially shorten pulse lengths. A prominent improvement in accuracy is also observed when large off -resonance gradients are present. A further boost in excitation accuracy can be accomplished in regions of interest (ROIs) if they are specified together with "don't-care" regions. The density compensation function (DCF) is no longer required. In addition, regularization techniques allow control over integrated and peak pulse power.
引用
收藏
页码:908 / 917
页数:10
相关论文
共 49 条
  • [21] Selective Excitation on Tip-Enhanced Raman Spectroscopy by Pulse Shaping Femtosecond Laser
    Yingjie Xia
    Hua Zhao
    Chunjie Zheng
    Shian Zhang
    Donghai Feng
    Zhenrong Sun
    Tianqing Jia
    Plasmonics, 2019, 14 : 523 - 531
  • [22] PULSE SEQUENCE DESIGN FOR VOLUME SELECTIVE EXCITATION IN MAGNETIC-RESONANCE
    JENSEN, DJ
    NARAYANA, PA
    DELAYRE, JL
    MEDICAL PHYSICS, 1987, 14 (01) : 38 - 42
  • [23] Radiofrequency Pulse Design for the Selective Excitation of Dissolved 129Xe
    Leung, General
    Norquay, Graham
    Schulte, Rolf F.
    Wild, Jim M.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (01) : 21 - 30
  • [24] Design of practical T2-selective RF excitation (TELEX) pulses
    Sussman, MS
    Pauly, JM
    Wright, GA
    MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (06) : 890 - 899
  • [25] Joint design of large-tip-angle parallel RF pulses and blipped gradient trajectories
    Cao, Zhipeng
    Donahue, Manus J.
    Ma, Jun
    Grissom, William A.
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (03) : 1198 - 1208
  • [26] Preserving the excitation profile of small flip angle RF pulses in the presence of rapid transverse relaxation
    Shen, Jun
    JOURNAL OF MAGNETIC RESONANCE, 2012, 224 : 8 - 12
  • [27] Correction of Excitation Profile in Zero Echo Time (ZTE) Imaging Using Quadratic Phase-Modulated RF Pulse Excitation and Iterative Reconstruction
    Li, Cheng
    Magland, Jeremy F.
    Seifert, Alan C.
    Wehrli, Felix W.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (04) : 961 - 969
  • [28] PARAMETER RELATIONS FOR THE SHINNAR-LEROUX SELECTIVE EXCITATION PULSE DESIGN ALGORITHM
    PAULY, J
    LEROUX, P
    NISHIMURA, D
    MACOVSKI, A
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (01) : 53 - 65
  • [29] Design and optimization for variable rate selective excitation using an analytic RF scaling function
    Gai, Neville D.
    Zur, Yuval
    JOURNAL OF MAGNETIC RESONANCE, 2007, 189 (01) : 78 - 89
  • [30] Phase matched RF pulse design for imaging a reduced field of excitation with a fast TSE acquisition
    Mooiweer, Ronald
    Sbrizzi, Alessandro
    Raaijmakers, Alexander J. E.
    van den Berg, Cornelis A. T.
    Luijten, Peter R.
    Hoogduin, Hans
    MAGNETIC RESONANCE IMAGING, 2018, 51 : 128 - 136