Joint design of large-tip-angle parallel RF pulses and blipped gradient trajectories

被引:23
|
作者
Cao, Zhipeng [1 ,2 ]
Donahue, Manus J. [1 ,3 ]
Ma, Jun [1 ,2 ]
Grissom, William A. [1 ,2 ,3 ,4 ]
机构
[1] Vanderbilt Univ, Inst Imaging Sci, 221 Kirkland Hall, Nashville, TN 37235 USA
[2] Vanderbilt Univ, Dept Biomed Engn, 5824 Stevenson Ctr, Nashville, TN 37235 USA
[3] Vanderbilt Univ, Dept Radiol, 221 Kirkland Hall, Nashville, TN 37235 USA
[4] Vanderbilt Univ, Dept Elect Engn, Nashville, TN 37235 USA
关键词
radiofrequency pulse design; ultrahigh field; parallel transmission; spokes pulses; k(T)-points pulses; optimal control; SPIN-ECHO BOLD; 7; T; HUMAN BRAIN; 8; CHANNELS; EXCITATION; TRANSMISSION; OPTIMIZATION; ALGORITHM; HUMANS; ROBUST;
D O I
10.1002/mrm.25739
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo design multichannel large-tip-angle -points and spokes radiofrequency (RF) pulses and gradient waveforms for transmit field inhomogeneity compensation in high field magnetic resonance imaging. Theory and MethodsAn algorithm to design RF subpulse weights and gradient blip areas is proposed to minimize a magnitude least-squares cost function that measures the difference between realized and desired state parameters in the spin domain, and penalizes integrated RF power. The minimization problem is solved iteratively with interleaved target phase updates, RF subpulse weights updates using the conjugate gradient method with optimal control-based derivatives, and gradient blip area updates using the conjugate gradient method. Two-channel parallel transmit simulations and experiments were conducted in phantoms and human subjects at 7 T to demonstrate the method and compare it to small-tip-angle-designed pulses and circularly polarized excitations. ResultsThe proposed algorithm designed more homogeneous and accurate 180 degrees inversion and refocusing pulses than other methods. It also designed large-tip-angle pulses on multiple frequency bands with independent and joint phase relaxation. Pulses designed by the method improved specificity and contrast-to-noise ratio in a finger-tapping spin echo blood oxygen level dependent functional magnetic resonance imaging study, compared with circularly polarized mode refocusing. ConclusionA joint RF and gradient waveform design algorithm was proposed and validated to improve large-tip-angle inversion and refocusing at ultrahigh field. Magn Reson Med 75:1198-1208, 2016. (c) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:1198 / 1208
页数:11
相关论文
共 36 条
  • [1] Fast Large-Tip-Angle Multidimensional and Parallel RF Pulse Design in MRI
    Grissom, William A.
    Xu, Dan
    Kerr, Adam B.
    Fessler, Jeffrey A.
    Noll, Douglas C.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (10) : 1548 - 1559
  • [2] Additive angle method for fast large-tip-angle RF pulse design in parallel excitation
    Grissom, William A.
    Yip, Chun-Yu
    Wright, Steven M.
    Fessler, Jeffrey A.
    Noll, Douglas C.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (04) : 779 - 787
  • [3] A LINEAR CLASS OF LARGE-TIP-ANGLE SELECTIVE EXCITATION PULSES
    PAULY, J
    NISHIMURA, D
    MACOVSKI, A
    JOURNAL OF MAGNETIC RESONANCE, 1989, 82 (03): : 571 - 587
  • [4] A noniterative method to design large-tip-angle multidimensional spatially-selective radio frequency pulses for parallel transmission
    Xu, Dan
    King, Kevin F.
    Zhu, Yudong
    McKinnon, Graeme C.
    Liang, Zhi-Pei
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (02) : 326 - 334
  • [5] Joint Design of Spoke Trajectories and RF Pulses for Parallel Excitation
    Ma, Chao
    Xu, Dan
    King, Kevin F.
    Liang, Zhi-Pei
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (04) : 973 - 985
  • [6] Joint design of trajectory and RF pulses for parallel excitation
    Yip, Chun-Yu
    Grissom, William A.
    Fessler, Jeffrey A.
    Noll, Douglas C.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (03) : 598 - 604
  • [7] Joint design of kT-points trajectories and RF pulses under explicit SAR and power constraints in the large flip angle regime
    Gras, Vincent
    Luong, Michel
    Amadon, Alexis
    Boulant, Nicolas
    JOURNAL OF MAGNETIC RESONANCE, 2015, 261 : 181 - 189
  • [8] LARGE-TIP-ANGLE SPIN-ECHO IMAGING - THEORY AND APPLICATIONS
    ELSTER, AD
    PROVOST, TJ
    INVESTIGATIVE RADIOLOGY, 1993, 28 (10) : 944 - 953
  • [9] Efficient method to design RF pulses for parallel excitation MRI using gridding and conjugate gradient
    Feng, Shuo
    Ji, Jim
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2014, 4 (02) : 87 - 92
  • [10] FastPtx: a versatile toolbox for rapid, joint design of pTx RF and gradient pulses using Pytorch's autodifferentiation
    Bosch, Dario
    Scheffler, Klaus
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2024, 37 (01) : 127 - 138