Reliability and validity of hand-held dynamometry for assessing lower limb muscle strength

被引:7
|
作者
Lipovsek, Tjasa [1 ]
Kacin, Alan [1 ]
Puh, Urska [1 ]
机构
[1] Univ Ljubljana, Fac Hlth Sci, Dept Physiotherapy, Ljubljana, Slovenia
关键词
Muscle strength; isometric contraction; dynamometer; reliability; validity; KNEE-JOINT ANGLE; EXTREMITY; PERFORMANCE; FLEXION; VALUES;
D O I
10.3233/IES-210168
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
BACKGROUND: Hand-held dynamometry (HHD) is used to assess muscle strength in various patient populations, but many variations in protocols exist. OBJECTIVE: First, to systematically develop a protocol of HHD for all lower limb muscle groups and evaluate intra-rater reliability; second, to validate HHD with fixed dynamometry for the knee flexor and extensor muscles. METHODS: Thirty healthy young adults (women: men - 15:15) participated in two testing sessions. HHD of 12 lower limb muscle groups was performed in both sessions, while fixed dynamometry of knee muscle groups was performed only in the second session. RESULTS: The intra-rater reliability of HHD was good for five muscle groups and excellent for seven muscle groups (ICC3, k = 0.80-0.96). The criterion validity of HHD ranged from very good to excellent for the knee flexors (r = 0.77-0.89) and from good to very good for the knee extensors (r = 0.65-0.78). However, peak moment values for the knee extensor muscles were underestimated by 32% (p < 0.001). CONCLUSIONS: The proposed HHD protocol provides reliable and valid measurements of lower limb muscle isometric strength in healthy adults, which may also be used to test patients with mild muscle strength deficits. However, possible underestimation of absolute strength must be considered when interpreting the results of knee extensors or other large muscles.
引用
收藏
页码:231 / 240
页数:10
相关论文
共 50 条
  • [21] VALIDITY OF HAND-HELD DYNAMOMETRY IN MEASURING QUADRICEPS STRENGTH AND RATE OF TORQUE DEVELOPMENT
    Lesnak, Joseph
    Anderson, Dillon
    Farmer, Brooke
    Katsavelis, Dimitrios
    Grindstaff, Terry L.
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2019, 14 (02): : 180 - 187
  • [22] CONCURRENT VALIDITY OF HAND-HELD SPHYGMOMANOMETER DYNAMOMETRY FOR MEASURING THIGH MUSCLE STRENGTHS
    Wood, Laurence R.
    Hay, Elaine M.
    Sim, Julius
    RHEUMATOLOGY, 2009, 48 : I159 - I159
  • [23] Measuring muscle strength for people with chronic obstructive pulmonary disease: Retest reliability of hand-held dynamometry
    O'Shea, Simone D.
    Taylor, Nicholas F.
    Paratz, Jennifer D.
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2007, 88 (01): : 32 - 36
  • [24] Inter-Tester Reliability and Precision of Manual Muscle Testing and Hand-Held Dynamometry in Lower Limb Muscles of Children with Spina Bifida
    Mahony, Kate
    Hunt, Adrienne
    Daley, Deborah
    Sims, Susan
    Adams, Roger
    PHYSICAL & OCCUPATIONAL THERAPY IN PEDIATRICS, 2009, 29 (01) : 44 - 59
  • [25] Hand-held dynamometry: Reliability of lower extremity muscle testing in healthy, physically active, young adults
    Kelln, Brent M.
    McKeon, Patrick O.
    Gontkof, Lauren M.
    Hertel, Jay
    JOURNAL OF SPORT REHABILITATION, 2008, 17 (02) : 160 - 170
  • [26] Validity And Reliability Of Hand-held Dynamometer In Assessing Isometric Leg Strength In Older Adults
    Lee, Chong-Do
    Lee, Samuel
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2022, 54 (09) : 477 - 477
  • [27] Reliability of hand-held dynamometry in spinal muscular atrophy
    Merlini, L
    Mazzone, ES
    Solari, A
    Morandi, L
    MUSCLE & NERVE, 2002, 26 (01) : 64 - 70
  • [28] Hand-held dynamometry reliability in persons with neuropathic weakness
    Kilmer, DD
    McCrory, MA
    Wright, NC
    Rosko, RA
    Kim, HR
    Aitkens, SG
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1997, 78 (12): : 1364 - 1368
  • [29] A New Tool to Assess Muscle Strength in Polymyositis and Dermatomyositis: Hand-Held Dynamometry
    Saygin, Didem
    Oddis, Chester V.
    Moghadam-Kia, Siamak
    Koontz, Diane
    Neiman, Nicole Marie
    Aggarwal, Rohit
    ARTHRITIS & RHEUMATOLOGY, 2018, 70
  • [30] THE VALIDITY OF PLANTARFLEXOR STRENGTH MEASURES OBTAINED THROUGH HAND-HELD DYNAMOMETRY MEASUREMENTS OF FORCE
    Marmon, Adam R.
    Pozzi, Federico
    Alnahdi, Ali H.
    Zeni, Joseph A.
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2013, 8 (06): : 820 - 827