Reliability of hand-held dynamometry in spinal muscular atrophy

被引:117
|
作者
Merlini, L
Mazzone, ES
Solari, A
Morandi, L
机构
[1] Ist Ortoped Rizzoli, Neuromuscular Unit, I-40136 Bologna, Italy
[2] Ist Nazl Neurol C Besta, Lab Epidemiol, Milan, Italy
[3] Ist Nazl Neurol C Besta, Dept Neuromuscular Dis, Milan, Italy
关键词
clinical trial; hand-held myometry; maximal voluntary isometric contraction; reliability; spinal muscular atrophy;
D O I
10.1002/mus.10166
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We have assessed the reliability of hand-held myometry in 33 patients with spinal muscular atrophy (SMA), testing elbow flexion, handgrip, three-point pinch, knee flexion, knee extension, and foot dorsiflexion, and determining intraclass correlation coefficients (ICC). Interrater reliability was high for upper limbs, with an ICC of 0.92 for three-point pinch and 0.98 for elbow flexion and grip. For lower limbs interrater reliability was good with ICC>0.85 for all measures except foot dorsiflexion. Test-retest results were excellent with ICC >0.91 in all instances. Hand-held myometry is easily performed in SMA patients of various ages and muscle strengths, is a reliable measure of limb muscle strength, and can be used in longitudinal studies and clinical trials. (C) 2002 Wiley Periodicals, Inc.
引用
收藏
页码:64 / 70
页数:7
相关论文
共 50 条
  • [1] INTERRATER RELIABILITY OF HAND-HELD DYNAMOMETRY
    BOHANNON, RW
    ANDREWS, AW
    [J]. PHYSICAL THERAPY, 1987, 67 (06): : 931 - 933
  • [2] Validity and Reliability of Hand-Held Dynamometry for Abdominal Flexion Muscular Assessment
    Tarca, Brett D.
    Wycherley, Thomas P.
    Meade, Anthony
    Bennett, Paul
    Ferrar, Katia E.
    [J]. JOURNAL OF SPORT REHABILITATION, 2021, 30 (02) : 343 - 346
  • [3] RELIABILITY OF HAND-HELD DYNAMOMETRY IN MEASURING MUSCLE STRENGTH
    BURDETT, RG
    WHITNEY, SL
    [J]. PHYSICAL THERAPY, 1987, 67 (05): : 748 - 748
  • [4] Hand-held dynamometry reliability in persons with neuropathic weakness
    Kilmer, DD
    McCrory, MA
    Wright, NC
    Rosko, RA
    Kim, HR
    Aitkens, SG
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1997, 78 (12): : 1364 - 1368
  • [5] Hand-held dynamometry: factors influencing reliability and validity
    Bohannon, RW
    [J]. CLINICAL REHABILITATION, 1997, 11 (03) : 263 - 264
  • [6] Adoption of hand-held dynamometry
    Bohannon, RW
    [J]. PERCEPTUAL AND MOTOR SKILLS, 2001, 92 (01) : 150 - 150
  • [7] Comparison of quantitative muscle testing and hand-held myometer in spinal muscular atrophy
    Hynan, Linda
    Glanzman, Allan
    Nelson, Leslie
    Finkel, Richard
    Iannaccone, Susan
    [J]. NEUROMUSCULAR DISORDERS, 2006, 16 : S115 - S115
  • [8] Comparison of quantitative muscle testing and hand-held myometry in spinal muscular atrophy
    Hynan, L. S.
    Glanzman, A.
    Nelson, L.
    Finkel, R. S.
    Iannaccone, S. T.
    [J]. NEUROMUSCULAR DISORDERS, 2006, 16 (9-10) : 668 - 669
  • [9] RELIABILITY OF HAND-HELD DYNAMOMETRY IN PATIENTS AWAITING TOTAL KNEE ARTHROPLASTY
    Neeter, C.
    Scholtes, V. A.
    Lambrecht, Y.
    Koblbauer, I.
    van der Hulst, M.
    Engelbert, R. H.
    Poolman, R. W.
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2010, 18 : S130 - S130
  • [10] Intertester reliability of hand-held dynamometry: A concise summary of published research
    Bohannon, RW
    [J]. PERCEPTUAL AND MOTOR SKILLS, 1999, 88 (03) : 899 - 902