Reliability and validity of hand-held dynamometry for assessing lower limb muscle strength

被引:7
|
作者
Lipovsek, Tjasa [1 ]
Kacin, Alan [1 ]
Puh, Urska [1 ]
机构
[1] Univ Ljubljana, Fac Hlth Sci, Dept Physiotherapy, Ljubljana, Slovenia
关键词
Muscle strength; isometric contraction; dynamometer; reliability; validity; KNEE-JOINT ANGLE; EXTREMITY; PERFORMANCE; FLEXION; VALUES;
D O I
10.3233/IES-210168
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
BACKGROUND: Hand-held dynamometry (HHD) is used to assess muscle strength in various patient populations, but many variations in protocols exist. OBJECTIVE: First, to systematically develop a protocol of HHD for all lower limb muscle groups and evaluate intra-rater reliability; second, to validate HHD with fixed dynamometry for the knee flexor and extensor muscles. METHODS: Thirty healthy young adults (women: men - 15:15) participated in two testing sessions. HHD of 12 lower limb muscle groups was performed in both sessions, while fixed dynamometry of knee muscle groups was performed only in the second session. RESULTS: The intra-rater reliability of HHD was good for five muscle groups and excellent for seven muscle groups (ICC3, k = 0.80-0.96). The criterion validity of HHD ranged from very good to excellent for the knee flexors (r = 0.77-0.89) and from good to very good for the knee extensors (r = 0.65-0.78). However, peak moment values for the knee extensor muscles were underestimated by 32% (p < 0.001). CONCLUSIONS: The proposed HHD protocol provides reliable and valid measurements of lower limb muscle isometric strength in healthy adults, which may also be used to test patients with mild muscle strength deficits. However, possible underestimation of absolute strength must be considered when interpreting the results of knee extensors or other large muscles.
引用
收藏
页码:231 / 240
页数:10
相关论文
共 50 条
  • [41] Manual muscle testing and hand-held dynamometry in people with inflammatory myopathy: An intra- and interrater reliability and validity study
    Pfister, Pierrette Baschung
    de Bruin, Eling D.
    Sterkele, Iris
    Maurer, Britta
    de Bie, Rob A.
    Knols, Ruud H.
    PLOS ONE, 2018, 13 (03):
  • [42] Assessment of Postural Muscle Strength in Sitting: Reliability of Measures Obtained with Hand-Held Dynamometry in Individuals with Spinal Cord Injury
    Larson, Cathy A.
    Tezak, Wynne Dawley
    Malley, Meghan Sheppard
    Thornton, William
    JOURNAL OF NEUROLOGIC PHYSICAL THERAPY, 2010, 34 (01): : 24 - 31
  • [43] Absolute Reliability and Concurrent Validity of Hand-Held Dynamometry in Shoulder Rotator Strength Assessment: Systematic Review and Meta-Analysis
    Chamorro, Claudio
    Arancibia, Miguel
    Trigo, Benjamin
    Arias-Poblete, Leonidas
    Jerez-Mayorga, Daniel
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (17)
  • [44] Investigating the Test-Retest Reliability and Validity of Hand-Held Dynamometry for Measuring Knee Strength in Older Women with Knee Osteoarthritis
    Chopp-Hurley, Jaclyn N.
    Wiebenga, Emily G.
    Gatti, Anthony A.
    Maly, Monica R.
    PHYSIOTHERAPY CANADA, 2019, 71 (03) : 231 - 238
  • [45] TEST-RETEST RELIABILITY OF HAND-HELD DYNAMOMETRY DURING A SINGLE SESSION OF STRENGTH ASSESSMENT
    BOHANNON, RW
    PHYSICAL THERAPY, 1986, 66 (02): : 206 - 209
  • [46] RELIABILITY OF HAND-HELD DYNAMOMETRY AND ITS RELATIONSHIP WITH MANUAL MUSCLE TESTING IN PATIENTS WITH OSTEOARTHRITIS IN THE KNEE
    HAYES, KW
    FALCONER, J
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1992, 16 (03): : 145 - 149
  • [47] Lower Extremity Strength Profile in Ambulatory Adults with Cerebral Palsy and Spastic Diplegia: Norm Values and Reliability for Hand-Held Dynamometry
    Eken, Maaike M.
    Lamberts, Robert P.
    Koschnick, Susanne
    Du Toit, Jacques
    Veerbeek, Berendina E.
    Langerak, Nelleke G.
    PM&R, 2020, 12 (06) : 573 - 580
  • [48] Literature reporting normative data for muscle strength measured by hand-held dynamometry: A systematic review
    Bohannon, Richard W.
    ISOKINETICS AND EXERCISE SCIENCE, 2011, 19 (03) : 143 - 147
  • [49] RELIABILITY OF HAND-HELD DYNAMOMETRY IN PATIENTS AWAITING TOTAL KNEE ARTHROPLASTY
    Neeter, C.
    Scholtes, V. A.
    Lambrecht, Y.
    Koblbauer, I.
    van der Hulst, M.
    Engelbert, R. H.
    Poolman, R. W.
    OSTEOARTHRITIS AND CARTILAGE, 2010, 18 : S130 - S130
  • [50] Test retest reliabilities of hand-held dynamometer for lower-limb muscle strength in intellectual disabilities
    Wuang, Yee-Pay
    Chang, Jyh-Jong
    Wang, Min-Hung
    Lin, Hsiu-Ching
    RESEARCH IN DEVELOPMENTAL DISABILITIES, 2013, 34 (08) : 2281 - 2290