Reliability and validity of hand-held dynamometry for assessing lower limb muscle strength

被引:5
|
作者
Lipovsek, Tjasa [1 ]
Kacin, Alan [1 ]
Puh, Urska [1 ]
机构
[1] Univ Ljubljana, Fac Hlth Sci, Dept Physiotherapy, Ljubljana, Slovenia
关键词
Muscle strength; isometric contraction; dynamometer; reliability; validity; KNEE-JOINT ANGLE; EXTREMITY; PERFORMANCE; FLEXION; VALUES;
D O I
10.3233/IES-210168
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
BACKGROUND: Hand-held dynamometry (HHD) is used to assess muscle strength in various patient populations, but many variations in protocols exist. OBJECTIVE: First, to systematically develop a protocol of HHD for all lower limb muscle groups and evaluate intra-rater reliability; second, to validate HHD with fixed dynamometry for the knee flexor and extensor muscles. METHODS: Thirty healthy young adults (women: men - 15:15) participated in two testing sessions. HHD of 12 lower limb muscle groups was performed in both sessions, while fixed dynamometry of knee muscle groups was performed only in the second session. RESULTS: The intra-rater reliability of HHD was good for five muscle groups and excellent for seven muscle groups (ICC3, k = 0.80-0.96). The criterion validity of HHD ranged from very good to excellent for the knee flexors (r = 0.77-0.89) and from good to very good for the knee extensors (r = 0.65-0.78). However, peak moment values for the knee extensor muscles were underestimated by 32% (p < 0.001). CONCLUSIONS: The proposed HHD protocol provides reliable and valid measurements of lower limb muscle isometric strength in healthy adults, which may also be used to test patients with mild muscle strength deficits. However, possible underestimation of absolute strength must be considered when interpreting the results of knee extensors or other large muscles.
引用
收藏
页码:231 / 240
页数:10
相关论文
共 50 条
  • [31] Hand-held dynamometry: A practicable alternative for obtaining objective measures of muscle strength
    Bohannon, Richard W.
    [J]. ISOKINETICS AND EXERCISE SCIENCE, 2012, 20 (04) : 301 - 315
  • [32] Criterion Validity of Hand-Held Dynamometry to Assess Quadriceps Strength in Patients with Lung Disease
    Burtin, C.
    De Brandt, J.
    Spruit, M. A.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197
  • [33] Psychometric properties of a standardized protocol of muscle strength assessment by hand-held dynamometry in healthy adults: a reliability study
    Morin, Marika
    Hebert, Luc J.
    Perron, Marc
    Petitclerc, Emilie
    Lake, Shanna-Rose
    Duchesne, Elise
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [34] Adoption of hand-held dynamometry
    Bohannon, RW
    [J]. PERCEPTUAL AND MOTOR SKILLS, 2001, 92 (01) : 150 - 150
  • [35] Reliability, Concurrent Validity, and Minimal Detectable Change of the Hand-Held Dynamometry for the Assessment of Knee Muscle Strength in Patients With Revision Total Knee Arthroplasty
    Eymir, Musa
    Unver, Bayram
    Karatosun, Vasfi
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2024, 105 (01): : 34 - 39
  • [36] Psychometric properties of a standardized protocol of muscle strength assessment by hand-held dynamometry in healthy adults: a reliability study
    Marika Morin
    Luc J. Hébert
    Marc Perron
    Émilie Petitclerc
    Shanna-Rose Lake
    Elise Duchesne
    [J]. BMC Musculoskeletal Disorders, 24
  • [37] Isometric strength of upper limb muscles in youth using hand-held and hand-grip dynamometry
    Mendez-Rebolledo, Guillermo
    Ruiz-Gutierrez, Arturo
    Salas-Villar, Sebastian
    Guzman-Munoz, Eduardo
    Sazo-Rodriguez, Sergio
    Urbina-Santibanez, Eric
    [J]. JOURNAL OF EXERCISE REHABILITATION, 2022, 18 (03) : 203 - 213
  • [38] Reliability of hand-held dynamometry in assessment of knee extensor strength following hip fracture
    Roy, MA
    Miller, TA
    Doherty, TJ
    [J]. JOURNAL OF AGING AND PHYSICAL ACTIVITY, 2004, 12 (03) : 329 - 329
  • [39] Reliability of hand-held dynamometry in assessment of knee extensor strength after hip fracture
    Mag, R
    Doherty, TJ
    [J]. AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2004, 83 (11) : 813 - 818
  • [40] Validity and reliability of serratus anterior hand held dynamometry
    Jos IJspeert
    Hans C. J. W. Kerstens
    Renske M. J. Janssen
    Alexander C. H. Geurts
    Nens van Alfen
    Jan T. Groothuis
    [J]. BMC Musculoskeletal Disorders, 20