Schiff base modified screen printed electrode for selective determination of aluminium(III) at trace level

被引:50
|
作者
Rana, Sonia [1 ]
Mittal, Susheel K. [1 ]
Singh, Narinder [2 ]
Singh, Jasminder [2 ]
Banks, Craig E. [3 ]
机构
[1] Thapar Univ, Sch Chem & Biochem, Patiala 147004, Punjab, India
[2] Indian Inst Technol Ropar, Dept Chem, Rupnagar 140001, Punjab, India
[3] Manchester Metropolitan Univ, Div Chem & Environm Sci, Sch Chem & Environm, Chester St, Manchester M1 5GD, Lancs, England
关键词
Schiff base modified screen printed electrode; Voltammetric sensor; Differential pulse voltammetry; Density functional theory; Aluminium; ON FLUORESCENT CHEMOSENSOR; ADSORPTIVE STRIPPING VOLTAMMETRY; ELECTROCHEMICAL SENSOR; ALZHEIMERS-DISEASE; BIOLOGICAL SAMPLES; AL3+; AL(III); SPECIATION; BIOSENSORS; TOXICITY;
D O I
10.1016/j.snb.2016.07.133
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical method for determination of Al(III) has been developed using Schiff base (JS-1) modified screen printed electrodes as a disposable chemosensor. The modified screen printed electrode was characterized with voltammetry and was further confirmed by SEM and EDX data. Differential pulse voltammogram of modified SPE in the presence of Al(III) showed a characteristic peak current at -0.054 V. A linear response of the sensor was observed in the concentration range of 0.67-4.59 mu g L-1 of the analyte. The limit of detection (LOD) was found to be 2.26 ng L-1 for Al(III). The proposed chemosensor selectively detects Al(III) in the presence of some alkali, alkaline earth, transition metal ions like Zn(II), Cd(II), Hg(II) and Pb(II). Complexation behavior of the ionophore for the metal ion has also been supported by theoretical studies. The method has been used for the determination of Al(III) in the natural water samples. The proposed voltammetric sensor can be reused after washing with EDTA (0.1 M) as a cleaning agent. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:17 / 27
页数:11
相关论文
共 50 条
  • [41] A new screen-printed electrode for selective determination of bismuth in different authentic samples
    Aglan, Refaat F.
    Hamed, Mostafa M.
    Saleh, Hosam M.
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2023, 20 (06) : 1481 - 1490
  • [42] Ion-selective electrode for potentiometric determination of aluminium(III) in fluoride medium
    Piccin, E
    Fatibello, O
    Ramos, LA
    QUIMICA NOVA, 2004, 27 (06): : 901 - 904
  • [43] Modified Screen-Printed Electrode for Potentiometric Determination of Copper(II) in Water Samples
    Ali, Tamer Awad
    Mohamed, Gehad G.
    El-Dessouky, Maher M. I.
    Abou El-Ella, Salwa M.
    Mohamed, Rabab T. F.
    JOURNAL OF SOLUTION CHEMISTRY, 2013, 42 (06) : 1336 - 1354
  • [44] Zn Nanoparticles Modified Screen Printed Carbon Electrode as a Promising Sensor for Insulin Determination
    Sisolakova, Ivana
    Hovancova, Jana
    Chovancova, Frederika
    Orinakova, Renata
    Maskal'ova, Iveta
    Orinak, Andrej
    Jozef Radonak
    ELECTROANALYSIS, 2021, 33 (03) : 627 - 634
  • [45] Voltammetric determination of doxycycline in feedstock using modified carbon screen-printed electrode
    M. S. Tiwari
    R. G. Thorat
    B. B. Popatkar
    V. V. Borge
    A. K. Kadu
    Analytical Sciences, 2023, 39 : 1889 - 1899
  • [46] Molecularly Imprinted Polypyrrole-Modified Screen-Printed Electrode for Dopamine Determination
    Merli, Daniele
    Cutaia, Alessandra
    Hallulli, Ines
    Bonanni, Alessandra
    Alberti, Giancarla
    POLYMERS, 2024, 16 (17)
  • [47] Voltammetric determination of doxycycline in feedstock using modified carbon screen-printed electrode
    Tiwari, M. S.
    Thorat, R. G.
    Popatkar, B. B.
    Borge, V. V.
    Kadu, A. K.
    ANALYTICAL SCIENCES, 2023, 39 (11) : 1889 - 1899
  • [48] Determination of bisphenol A in real samples using modified graphite screen-printed electrode
    Safavi Gerdin, Hesam
    Sarhadi, Hamid
    Tajik, Somayeh
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2022, 102 (17) : 4986 - 4995
  • [49] Pb(II) Determination in a Single Drop Using a Modified Screen-Printed Electrode
    Zurga, Nika
    Majer, David
    Finsgar, Matjaz
    CHEMOSENSORS, 2021, 9 (02) : 1 - 10
  • [50] Modified Screen-Printed Electrode for Potentiometric Determination of Copper(II) in Water Samples
    Tamer Awad Ali
    Gehad G. Mohamed
    Maher M. I. El-Dessouky
    Salwa M. Abou El-Ella
    Rabab T. F. Mohamed
    Journal of Solution Chemistry, 2013, 42 : 1336 - 1354