A new screen-printed electrode for selective determination of bismuth in different authentic samples

被引:1
|
作者
Aglan, Refaat F. [1 ,2 ]
Hamed, Mostafa M. [1 ,2 ]
Saleh, Hosam M. [3 ]
机构
[1] Egyptian Atom Energy Author, Analyt Chem & Control Dept, Hot Labs, Cairo 13759, Egypt
[2] Egyptian Atom Energy Author, Waste Management Ctr, Cairo 13759, Egypt
[3] Egyptian Atom Energy Author, Nucl Res Ctr, Radioisotope Dept, Cairo, Egypt
关键词
Potentiometric sensors; Bi(III); Screen-printed ion-selective electrode; Cerium zirconium phosphotungstate; CARBON-PASTE ELECTRODES; POTENTIOMETRIC DETERMINATION; ONLINE PRECONCENTRATION; MEMBRANE-ELECTRODE; ION; WATER; EXTRACTION; SYSTEM; WASTE;
D O I
10.1007/s13738-023-02771-4
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A new potentiometric method based on the screen-printed ion-selective electrode (SPISE) was described for the determination of Bi(III) ion in different authentic samples. The novelty is based on, for the first time, the utilization of the cerium zirconium phosphotungstate (CZPT) in a screen-printed electrode (SPE) as a sensing material. In the literature, there is no screen-printed ion-selective electrode for the determination of Bi(III) ion. The influences of the paste composition, different conditioning parameters and foreign ions on the electrode performance were investigated. The reversibility and also response time of the electrode have been studied. The electrode showed a Nernstian response of 18.2 mV decade(-1) in the concentration range of 3.3 x 10(-7)-1 x 10(-1) mol. L-1. The electrode was found to be usable within the pH range of 3.5-8.0 and exhibited a fast response time, limit of detection (LOD) (1 x 10(-7) mol. L-1), limit of quantification (LOQ) (3.33 x 10(-7) mol. L-1), long lifetime and good stability. The matched potential method (MPM) was applied to determine the selectivity coefficient. The isothermal temperature coefficient (dE(o)/dt) of the electrode was calculated. The electrode was successfully applied for the determination of Bi(III) ion in different authentic samples. By comparing the current results with those obtained using inductively coupled plasma optical emission spectrometry, the nominated Bi(III) screen-printed ion-selective electrode has attained acceptable and efficient performance.
引用
收藏
页码:1481 / 1490
页数:10
相关论文
共 50 条
  • [1] A new screen-printed electrode for selective determination of bismuth in different authentic samples
    Refaat F. Aglan
    Mostafa M. Hamed
    Hosam M. Saleh
    Journal of the Iranian Chemical Society, 2023, 20 : 1481 - 1490
  • [2] New Chemically Modified Screen-Printed Electrode for Co(II) Determination in Different Water Samples
    Ali, Tamer Awad
    Aglan, Refat F.
    Mohamed, Gehad G.
    Mourad, Mai A.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (04): : 1812 - 1826
  • [3] Selective Thiol Detection in Authentic Biological Samples with the Use of Screen-printed Electrodes
    Patricia T. Lee
    Richard G. Compton
    Analytical Sciences, 2015, 31 : 685 - 691
  • [4] Selective Thiol Detection in Authentic Biological Samples with the Use of Screen-printed Electrodes
    Lee, Patricia T.
    Compton, Richard G.
    ANALYTICAL SCIENCES, 2015, 31 (07) : 685 - 691
  • [5] Screen-printed ion-selective electrode for potassium determination
    Piorek, Izabella
    Peplowski, Andrzej
    Jakubowska, Malgorzata
    PHOTONICS APPLICATIONS IN ASTRONOMY, COMMUNICATIONS, INDUSTRY, AND HIGH-ENERGY PHYSICS EXPERIMENTS 2019, 2019, 11176
  • [6] Novel screen-printed electrode for the determination of dodecyltrimethylammonium bromide in water samples
    Mohamed, Gehad G.
    Ali, Tamer Awad
    El-Shahat, M. F.
    Migahed, M. A.
    Al-Sabagh, A. M.
    DRUG TESTING AND ANALYSIS, 2012, 4 (12) : 1009 - 1013
  • [7] A New Screen-printed Ion Selective Electrode for Determination of Citalopram Hydrobromide in Pharmaceutical Formulation
    Ali, Tamer Awad
    Mohamed, Gehad G.
    Al-Sabagh, A. M.
    Migahed, M. A.
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 42 (04) : 565 - 572
  • [8] Green Electrochemical Sensor for Caffeine Determination in Environmental Water Samples: The Bismuth Film Screen-Printed Carbon Electrode
    Tyszczuk-Rotko, Katarzyna
    Szwagierek, Agnieszka
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (07) : B342 - B348
  • [9] Modified Screen-Printed Ion Selective Electrodes for Potentiometric Determination of Sodium Dodecylsulfate in Different Samples
    Ali, Tamer Awad
    Mohamed, Gehad G.
    JOURNAL OF AOAC INTERNATIONAL, 2015, 98 (01) : 116 - 123