Schiff base modified screen printed electrode for selective determination of aluminium(III) at trace level

被引:50
|
作者
Rana, Sonia [1 ]
Mittal, Susheel K. [1 ]
Singh, Narinder [2 ]
Singh, Jasminder [2 ]
Banks, Craig E. [3 ]
机构
[1] Thapar Univ, Sch Chem & Biochem, Patiala 147004, Punjab, India
[2] Indian Inst Technol Ropar, Dept Chem, Rupnagar 140001, Punjab, India
[3] Manchester Metropolitan Univ, Div Chem & Environm Sci, Sch Chem & Environm, Chester St, Manchester M1 5GD, Lancs, England
关键词
Schiff base modified screen printed electrode; Voltammetric sensor; Differential pulse voltammetry; Density functional theory; Aluminium; ON FLUORESCENT CHEMOSENSOR; ADSORPTIVE STRIPPING VOLTAMMETRY; ELECTROCHEMICAL SENSOR; ALZHEIMERS-DISEASE; BIOLOGICAL SAMPLES; AL3+; AL(III); SPECIATION; BIOSENSORS; TOXICITY;
D O I
10.1016/j.snb.2016.07.133
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical method for determination of Al(III) has been developed using Schiff base (JS-1) modified screen printed electrodes as a disposable chemosensor. The modified screen printed electrode was characterized with voltammetry and was further confirmed by SEM and EDX data. Differential pulse voltammogram of modified SPE in the presence of Al(III) showed a characteristic peak current at -0.054 V. A linear response of the sensor was observed in the concentration range of 0.67-4.59 mu g L-1 of the analyte. The limit of detection (LOD) was found to be 2.26 ng L-1 for Al(III). The proposed chemosensor selectively detects Al(III) in the presence of some alkali, alkaline earth, transition metal ions like Zn(II), Cd(II), Hg(II) and Pb(II). Complexation behavior of the ionophore for the metal ion has also been supported by theoretical studies. The method has been used for the determination of Al(III) in the natural water samples. The proposed voltammetric sensor can be reused after washing with EDTA (0.1 M) as a cleaning agent. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:17 / 27
页数:11
相关论文
共 50 条
  • [31] Simultaneous electrochemical determination of epinephrine and acetylcholine using modified screen printed electrode
    Aflatoonian, Mohammad Reza
    Tajik, Somayeh
    Aflatoonian, Behnaz
    Ekrami-Kakhki, Mehri-Saddat
    Alizadeh, Reza
    EURASIAN CHEMICAL COMMUNICATIONS, 2020, 2 (05): : 563 - 572
  • [32] Electrochemical Determination of Hydrazine Based on Modified Screen-Printed Carbon Electrode
    Mohammadi, Sayed Zia
    Tajik, Somayeh
    Hamidian, Hooshang
    Mousazadeh, Farideh
    Emambakhsh, Fatemeh
    Sajadi, Pari-Sima
    Allahabadi, Hossein
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2025, 172 (01)
  • [33] A Copper Oxide Nanoparticle Modified Screen-printed Electrode for Determination of Mirtazapine
    El-Shal, Manal A.
    EGYPTIAN JOURNAL OF CHEMISTRY, 2019, 62 (09): : 1739 - 1748
  • [34] Determination of labile cadmium using a screen-printed electrode modified by a microwell
    Parat, Corinne
    Authier, Laurent
    Betelu, Stephanie
    Petrucciani, Nathalie
    Potin-Gautier, Martine
    ELECTROANALYSIS, 2007, 19 (2-3) : 403 - 406
  • [35] Electrochemical Sensor Based on a Modified Graphite Screen Printed Electrode for Amitriptyline Determination
    Nasab, Zoheira Bagheri
    Nejad, Fariba Garkani
    SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY, 2022, 58 (01) : 100 - 108
  • [36] Application of Graphite Screen Printed Electrode Modified with Indium(III) Mixed-ligand Nanocomplex for Voltammetric Determination of Amlodipine
    Parsa, Asghar
    Akbarzadeh-Torbati, Niloufar
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (06): : 716 - 727
  • [37] Determination of chromium(III) by differential pulse stripping voltammetry at a chitosan-gold nanocomposite modified screen printed electrode
    Wu, Shixin
    Sekar, Nadia Chandra
    Tan, Swee Ngin
    Xie, Hong
    Ng, Sum Huan
    ANALYTICAL METHODS, 2016, 8 (05) : 962 - 967
  • [38] Trace-Level Sensing of Phosphate for Natural Soils by a Nano-Screen-Printed Electrode
    Lu, Yuanyuan
    Lan, Qingwen
    Zhang, Chuxuan
    Liu, Boyi
    Wang, Xiaochun
    Xu, Xiangyang
    Liang, Xinqiang
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2021, 55 (19) : 13093 - 13102
  • [39] Schiff base modified Pt electrode as sensor for detecting Al(III) and Pb(II)
    Deka, Kangkana
    Das, Diganta Kumar
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 2017, 56 (08): : 832 - 837
  • [40] A new screen-printed electrode for selective determination of bismuth in different authentic samples
    Refaat F. Aglan
    Mostafa M. Hamed
    Hosam M. Saleh