Schiff base modified screen printed electrode for selective determination of aluminium(III) at trace level

被引:50
|
作者
Rana, Sonia [1 ]
Mittal, Susheel K. [1 ]
Singh, Narinder [2 ]
Singh, Jasminder [2 ]
Banks, Craig E. [3 ]
机构
[1] Thapar Univ, Sch Chem & Biochem, Patiala 147004, Punjab, India
[2] Indian Inst Technol Ropar, Dept Chem, Rupnagar 140001, Punjab, India
[3] Manchester Metropolitan Univ, Div Chem & Environm Sci, Sch Chem & Environm, Chester St, Manchester M1 5GD, Lancs, England
关键词
Schiff base modified screen printed electrode; Voltammetric sensor; Differential pulse voltammetry; Density functional theory; Aluminium; ON FLUORESCENT CHEMOSENSOR; ADSORPTIVE STRIPPING VOLTAMMETRY; ELECTROCHEMICAL SENSOR; ALZHEIMERS-DISEASE; BIOLOGICAL SAMPLES; AL3+; AL(III); SPECIATION; BIOSENSORS; TOXICITY;
D O I
10.1016/j.snb.2016.07.133
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical method for determination of Al(III) has been developed using Schiff base (JS-1) modified screen printed electrodes as a disposable chemosensor. The modified screen printed electrode was characterized with voltammetry and was further confirmed by SEM and EDX data. Differential pulse voltammogram of modified SPE in the presence of Al(III) showed a characteristic peak current at -0.054 V. A linear response of the sensor was observed in the concentration range of 0.67-4.59 mu g L-1 of the analyte. The limit of detection (LOD) was found to be 2.26 ng L-1 for Al(III). The proposed chemosensor selectively detects Al(III) in the presence of some alkali, alkaline earth, transition metal ions like Zn(II), Cd(II), Hg(II) and Pb(II). Complexation behavior of the ionophore for the metal ion has also been supported by theoretical studies. The method has been used for the determination of Al(III) in the natural water samples. The proposed voltammetric sensor can be reused after washing with EDTA (0.1 M) as a cleaning agent. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:17 / 27
页数:11
相关论文
共 50 条
  • [21] Electrochemical Behavior and Determination of Carbidopa on Modified Graphite Screen Printed Electrode
    Hajializadeh, Afsaneh
    Jahani, Shohreh
    Tajik, Somayeh
    Beitollahi, Hadi
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (04): : 404 - 413
  • [22] Pseudo Cavity of Schiff Base Ionophore Incorporated in Screen Printed Electrode for Sensing of Zn (II)
    Rana, Sonia
    Mittal, Susheel K.
    Kaur, Navneet
    Banks, Craig E.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (06) : B464 - B471
  • [23] Screen-Printed Carbon Electrode Modified with Poly-L-histidine Applied to Gold(III) Determination
    Bergamini, Marcio F.
    Santos, Daniela P.
    Zanoni, Maria Valnice B.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2009, 20 (01) : 100 - 106
  • [24] Selective determination of chloramphenicol at trace level in milk samples by the electrode modified with molecularly imprinted polymer
    Alizadeh, Taher
    Ganjali, Mohamad Reza
    Zare, Mashaalah
    Norouzi, Parviz
    FOOD CHEMISTRY, 2012, 130 (04) : 1108 - 1114
  • [25] Biosensor for aluminium(III) based on its inhibition of α-chymotrypsin immobilized on a screen-printed carbon electrode modified with gold nanoparticles
    Miriam Barquero-Quirós
    Olga Domínguez-Renedo
    Maria Asunción Alonso-Lomillo
    María Julia Arcos-Martínez
    Microchimica Acta, 2012, 179 : 65 - 70
  • [26] Biosensor for aluminium(III) based on its inhibition of α-chymotrypsin immobilized on a screen-printed carbon electrode modified with gold nanoparticles
    Barquero-Quiros, Miriam
    Dominguez-Renedo, Olga
    Asuncion Alonso-Lomillo, Maria
    Julia Arcos-Martinez, Maria
    MICROCHIMICA ACTA, 2012, 179 (1-2) : 65 - 70
  • [27] A highly selective salicylate electrode based on Schiff base complexes of cobalt(III)
    Chai, YQ
    Jiang, F
    Yuan, R
    Xu, L
    Xu, WJ
    ANALYTICAL LETTERS, 2003, 36 (11) : 2379 - 2392
  • [28] Determination of Zinc, Cadmium, Lead, Copper and Silver Using a Carbon Paste Electrode and a Screen Printed Electrode Modified with Chromium(III) Oxide
    Koudelkova, Zuzana
    Syrovy, Tomas
    Ambrozova, Pavlina
    Moravec, Zdenek
    Kubac, Lubomir
    Hynek, David
    Richtera, Lukas
    Adam, Vojtech
    SENSORS, 2017, 17 (08):
  • [29] APPLICATION OF A NAFION-SCHIFF BASE MODIFIED ELECTRODE IN ANODIC-STRIPPING VOLTAMMETRY FOR THE DETERMINATION OF TRACE AMOUNTS OF MERCURY
    LIU, KZ
    WU, QG
    LIU, HI
    ANALYST, 1990, 115 (06) : 835 - 837
  • [30] Electrochemical Sensor Based on a Modified Graphite Screen Printed Electrode for Amitriptyline Determination
    Surface Engineering and Applied Electrochemistry, 2022, 58 : 100 - 108