Cost Optimization of a Stand-Alone Hybrid Energy System with Fuel Cell and PV

被引:64
|
作者
Singh, Shakti [1 ]
Chauhan, Prachi [1 ]
Aftab, Mohd Asim [1 ]
Ali, Ikbal [2 ]
Hussain, S. M. Suhail [3 ]
Ustun, Taha Selim [3 ]
机构
[1] Thapar Inst Engn & Technol, Elect & Instrumentat Engn Dept, Patiala 147001, Punjab, India
[2] Jamia Millia Islamia, Dept Elect Engn, New Delhi 110025, India
[3] Natl Inst Adv Ind Sci & Technol, AIST FREA, Fukushima Renewable Energy Inst, Koriyama, Fukushima 9630298, Japan
关键词
ABC-PSO algorithm; fuel cells; hydrogen; optimization; sizing; IEC; 61850; IEC; 61850; FEASIBILITY; BIOMASS; MANAGEMENT; ALGORITHM; WIND;
D O I
10.3390/en13051295
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Renewable energy has become very popular in recent years. The amount of renewable generation has increased in both grid-connected and stand-alone systems. This is because it can provide clean energy in a cost-effective and environmentally friendly fashion. Among all varieties, photovoltaic (PV) is the ultimate rising star. Integration of other technologies with solar is enhancing the efficiency and reliability of the system. In this paper a fuel cell-solar photovoltaic (FC-PV)-based hybrid energy system has been proposed to meet the electrical load demand of a small community center in India. The system is developed with PV panels, fuel cell, an electrolyzer and hydrogen storage tank. Detailed mathematical modeling of this system as well as its operation algorithm have been presented. Furthermore, cost optimization has been performed to determine ratings of PV and Hydrogen system components. The objective is to minimize the levelized cost of electricity (LCOE) of this standalone system. This optimization is performed in HOMER software as well as another tool using an artificial bee colony (ABC). The results obtained by both methods have been compared in terms of cost effectiveness. It is evident from the results that for a 68 MWh/yr of electricity demand is met by the 129 kW Solar PV, 15 kW Fuel cell along with a 34 kW electrolyzer and a 20 kg hydrogen tank with a LPSP of 0.053%. The LCOE is found to be in 0.228 $/kWh. Results also show that use of more sophisticated algorithms such as ABC yields more optimized solutions than package programs, such as HOMER. Finally, operational details for FC-PV hybrid system using IEC 61850 inter-operable communication is presented. IEC 61850 information models for FC, electrolyzer, hydrogen tank were developed and relevent IEC 61850 message exchanges for energy management in FC-PV hybrid system are demonstrated.
引用
收藏
页数:23
相关论文
共 50 条
  • [41] Sizing Optimization of a Stand-Alone Hybrid Power Supply Unit: Wind/PV System with Battery Storage
    Belfkira, R.
    Barakat, G.
    Nichita, C.
    [J]. INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2008, 3 (05): : 820 - 828
  • [42] Implementation of a stand-alone fuel cell system for domestic applications
    Chiang, FK
    Lin, BR
    Ou, YA
    [J]. TENCON 2004 - 2004 IEEE REGION 10 CONFERENCE, VOLS A-D, PROCEEDINGS: ANALOG AND DIGITAL TECHNIQUES IN ELECTRICAL ENGINEERING, 2004, : D187 - D190
  • [43] Modeling and multi-objective optimization of a stand-alone PV-hydrogen-retired EV battery hybrid energy system
    Huang, Zhiyu
    Xie, Zhilong
    Zhang, Caizhi
    Chan, Siew Hwa
    Milewski, Jaroslaw
    Xie, Yi
    Yang, Yalian
    Hu, Xiaosong
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2019, 181 : 80 - 92
  • [44] Power Management of a Stand-Alone Wind/Photovoltaic/Fuel-Cell Energy System
    Wang, Caisheng
    Nehrir, Hashem
    [J]. 2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 748 - 748
  • [45] Sizing optimization, dynamic modeling and energy management strategies of a stand-alone PV/hydrogen/battery-based hybrid system
    Castaneda, Manuel
    Cano, Antonio
    Jurado, Francisco
    Sanchez, Higinio
    Fernandez, Luis M.
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2013, 38 (10) : 3830 - 3845
  • [46] An Improvized Fuel Cell System for Stand-Alone Mode Application
    Roy, Amit Kumar
    Biswal, Gyan Ranjan
    Padhy, Narayana Prasad
    [J]. 2016 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PESGM), 2016,
  • [47] PEM fuel cell degradation effects on the performance of a stand-alone solar energy system
    Ozden, Ender
    Tari, Ilker
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2017, 42 (18) : 13217 - 13225
  • [48] HYBRID SYSTEM FOR A STAND-ALONE APPLICATION
    Jaliu, C.
    Saulescu, R.
    Ciobanu, D.
    [J]. 2016 INTERNATIONAL CONFERENCE ON PRODUCTION RESEARCH - REGIONAL CONFERENCE AFRICA, EUROPE AND THE MIDDLE EAST (ICPR-AEM 2016) AND 4TH INTERNATIONAL CONFERENCE ON QUALITY AND INNOVATION IN ENGINEERING AND MANAGEMENT (QIEM 2016), 2016, : 124 - 129
  • [49] Robust optimal sizing of a hybrid energy stand-alone system
    Billionnet, Alain
    Costa, Marie-Christine
    Poirion, Pierre-Louis
    [J]. EUROPEAN JOURNAL OF OPERATIONAL RESEARCH, 2016, 254 (02) : 565 - 575
  • [50] On the Energy Management for a Stand-Alone Hybrid System in Isolated Area
    Lopez, Daniel
    Yahyaoui, Imene
    Tadeo, Fernando
    Arnaltes, Santiago
    [J]. 2019 10TH INTERNATIONAL RENEWABLE ENERGY CONGRESS (IREC), 2019,