Sizing optimization, dynamic modeling and energy management strategies of a stand-alone PV/hydrogen/battery-based hybrid system

被引:201
|
作者
Castaneda, Manuel [1 ]
Cano, Antonio [2 ]
Jurado, Francisco [2 ]
Sanchez, Higinio [3 ]
Fernandez, Luis M. [1 ]
机构
[1] Univ Cadiz, EPS Algeciras, Dept Elect Engn, Algeciras 11202, Cadiz, Spain
[2] Univ Jaen, EPS Linares, Dept Elect Engn, Linares 23700, Jaen, Spain
[3] Univ Cadiz, ESI Cadiz, Dept Elect Engn, Cadiz 11002, Spain
关键词
Sizing optimization; Hydrogen; Battery; Photovoltaic; Control strategies; POWER-GENERATION SYSTEM; RENEWABLE ENERGY; HYDROGEN-PRODUCTION; SIMULATION; STORAGE;
D O I
10.1016/j.ijhydene.2013.01.080
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This paper presents a sizing method and different control strategies for the suitable energy management of a stand-alone hybrid system based on photovoltaic (PV) solar panels, hydrogen subsystem and battery. The battery and hydrogen subsystem, which is composed of fuel cell (FC), electrolyzer and hydrogen storage tank, act as energy storage and support system. In order to efficiently utilize the energy sources integrated in the hybrid system, an appropriate sizing is necessary. In this paper, a new sizing method based on Simulink Design Optimization (SDO) of MATLAB was used to perform a technical optimization of the hybrid system components. An analysis cost has been also performed, in that the configuration under study has been compared with those integrating only batteries and only hydrogen system. The dynamic model of the designed hybrid system is detailed in this paper. The models, implemented in MATLAB-Simulink environment, have been designed from commercially available components. Three control strategies based on operating modes and combining technical-economic aspects are considered for the energy management of the hybrid system. They have been designed, primarily, to satisfy the load power demand and, secondarily, to maintain a certain level at the hydrogen tank (hydrogen energy reserve), and at the state of charge (SOC) of the battery bank to extend its life, taking into account also technical-economic analysis. Dynamic simulations were performed to evaluate the configuration, sizing and control strategies for the energy management of the hybrid system under study in this work. Simulation results show that the proposed hybrid system with the presented controls is able to provide the energy demanded by the loads, while maintaining a certain energy reserve in the storage sources. Copyright (C) 2013, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:3830 / 3845
页数:16
相关论文
共 50 条
  • [1] Dynamic Load Management and Optimum Sizing of Stand-Alone Hybrid PV/Wind System
    Kaplani, E.
    Ntafogiannis, P.
    Pappas, K.
    Diamantopoulos, N.
    [J]. INTERNATIONAL CONFERENCE OF COMPUTATIONAL METHODS IN SCIENCES AND ENGINEERING 2015 (ICCMSE 2015), 2015, 1702
  • [2] Energy Management of Stand-alone Hybrid PV System
    Wang, Chengjiang
    Chen, Wei
    Shao, Shao
    Chen, Zhenjie
    Zhu, Bin
    Li, Hongyan
    [J]. PROCEEDINGS OF INTERNATIONAL CONFERENCE ON SMART GRID AND CLEAN ENERGY TECHNOLOGIES (ICSGCE 2011), 2011, 12
  • [3] Optimal sizing of stand-alone hybrid wind/PV system with battery storage
    Belfkira, Rachid
    Hajji, Omessad
    Nichita, Cristian
    Barakat, Georges
    [J]. 2007 EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, VOLS 1-10, 2007, : 4339 - 4348
  • [4] Modeling and multi-objective optimization of a stand-alone PV-hydrogen-retired EV battery hybrid energy system
    Huang, Zhiyu
    Xie, Zhilong
    Zhang, Caizhi
    Chan, Siew Hwa
    Milewski, Jaroslaw
    Xie, Yi
    Yang, Yalian
    Hu, Xiaosong
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2019, 181 : 80 - 92
  • [5] Sizing Optimization of a Stand-Alone Hybrid Power Supply Unit: Wind/PV System with Battery Storage
    Belfkira, R.
    Barakat, G.
    Nichita, C.
    [J]. INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2008, 3 (05): : 820 - 828
  • [6] Optimal Sizing of a Stand-Alone Hybrid Power System Based on Battery/Hydrogen with an Improved Ant Colony Optimization
    Dong, Weiqiang
    Li, Yanjun
    Xiang, Ji
    [J]. ENERGIES, 2016, 9 (10)
  • [7] Adaptive Fuzzy Logic Controller Based Energy Management for a Stand-alone PV Hybrid System with Battery and Hydrogen Storage Path
    Warner, Konrad
    Bocklisch, Thilo
    [J]. PROCEEDINGS OF THE INTERNATIONAL RENEWABLE ENERGY STORAGE CONFERENCE, IRES 2022, 2023, 16 : 511 - 526
  • [8] Sizing optimization of a stand-alone street lighting system powered by a hybrid system using fuel cell, PV and battery
    Lagorse, Jeremy
    Paire, Damien
    Miraoui, Abdellatif
    [J]. RENEWABLE ENERGY, 2009, 34 (03) : 683 - 691
  • [9] Energy Management for Stand-alone PV System
    Zhu, Xianglin
    Liao, Zhiling
    [J]. 2009 ISECS INTERNATIONAL COLLOQUIUM ON COMPUTING, COMMUNICATION, CONTROL, AND MANAGEMENT, VOL IV, 2009, : 311 - 314
  • [10] Comparative performance analysis of a hybrid PV/FC/battery stand-alone system using different power management strategies and sizing approaches
    Behzadi, Mohammad Sadigh
    Niasati, Mohsen
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2015, 40 (01) : 538 - 548