Comparison of image quality from filtered back projection, statistical iterative reconstruction, and model-based iterative reconstruction algorithms in abdominal computed tomography

被引:24
|
作者
Kuo, Yu [1 ,2 ]
Lin, Yi-Yang [1 ,2 ]
Lee, Rheun-Chuan [1 ,2 ]
Lin, Chung-Jung [1 ,2 ]
Chiou, Yi-You [1 ,2 ]
Guo, Wan-Yuo [1 ,2 ]
机构
[1] Taipei Vet Gen Hosp, Dept Radiol, 201,Sect 2,Shipai Rd, Taipei 112, Taiwan
[2] Natl Yang Ming Univ, Sch Med, Taipei, Taiwan
关键词
abdomen; computed tomography; image quality; iterative model reconstruction; iterative reconstruction; radiation dosage; RENAL CYSTS; CT; REDUCTION; SIZE;
D O I
10.1097/MD.0000000000004456
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to compare the image noise-reducing abilities of iterative model reconstruction (IMR) with those of traditional filtered back projection (FBP) and statistical iterative reconstruction (IR) in abdominal computed tomography (CT) images This institutional review board-approved retrospective study enrolled 103 patients; informed consent was waived. Urinary bladder (n=83) and renal cysts (n=44) were used as targets for evaluating imaging quality. Raw data were retrospectively reconstructed using FBP, statistical IR, and IMR. Objective image noise and signal-to-noise ratio (SNR) were calculated and analyzed using one-way analysis of variance. Subjective image quality was evaluated and analyzed using Wilcoxon signed-rank test with Bonferroni correction. Objective analysis revealed a reduction in image noise for statistical IR compared with that for FBP, with no significant differences in SNR. In the urinary bladder group, IMR achieved up to 53.7% noise reduction, demonstrating a superior performance to that of statistical IR. IMR also yielded a significantly superior SNR to that of statistical IR. Similar results were obtained in the cyst group. Subjective analysis revealed reduced image noise for IMR, without inferior margin delineation or diagnostic confidence. IMR reduced noise and increased SNR to greater degrees than did FBP and statistical IR. Applying the IMR technique to abdominal CT imaging has potential for reducing the radiation dose without sacrificing imaging quality.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Comparison of image quality from filtered back projection, statistical iterative reconstruction, and model-based iterative reconstruction algorithms in abdominal computed tomography (vol 95, pg 31, 2016)
    Kuo, Y.
    Lin, Y-Y
    Lee, R-C
    [J]. MEDICINE, 2016, 95 (49)
  • [2] Computed Tomography Image Quality Evaluation of a New Iterative Reconstruction Algorithm in the Abdomen (Adaptive Statistical Iterative Reconstruction-V) a Comparison With Model-Based Iterative Reconstruction, Adaptive Statistical Iterative Reconstruction, and Filtered Back Projection Reconstructions
    Goodenberger, Martin H.
    Wagner-Bartak, Nicolaus A.
    Gupta, Shiva
    Liu, Xinming
    Yap, Ramon Q.
    Sun, Jia
    Tamm, Eric P.
    Jensen, Corey T.
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (02) : 184 - 190
  • [3] Clinical evaluation of image quality and radiation dose reduction in upper abdominal computed tomography using model-based iterative reconstruction; comparison with filtered back projection and adaptive statistical iterative reconstruction
    Nakamoto, Atsushi
    Kim, Tonsok
    Hori, Masatoshi
    Onishi, Hiromitsu
    Tsuboyama, Takahiro
    Sakane, Makoto
    Tatsumi, Mitsuaki
    Tomiyama, Noriyuki
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (09) : 1715 - 1723
  • [4] Assessment of Filtered Back Projection, Adaptive Statistical, and Model-Based Iterative Reconstruction for Reduced Dose Abdominal Computed Tomography
    Padole, Atul
    Singh, Sarabjeet
    Lira, Diego
    Blake, Michael A.
    Pourjabbar, Sarvenaz
    Khawaja, Ranish Deedar Ali
    Choy, Garry
    Saini, Sanjay
    Do, Synho
    Kalra, Mannudeep K.
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (04) : 462 - 467
  • [5] Quantitative analysis of emphysema and airway measurements according to iterative reconstruction algorithms: comparison of filtered back projection, adaptive statistical iterative reconstruction and model-based iterative reconstruction
    Ji Yung Choo
    Jin Mo Goo
    Chang Hyun Lee
    Chang Min Park
    Sang Joon Park
    Mi-Suk Shim
    [J]. European Radiology, 2014, 24 : 799 - 806
  • [6] Quantitative analysis of emphysema and airway measurements according to iterative reconstruction algorithms: comparison of filtered back projection, adaptive statistical iterative reconstruction and model-based iterative reconstruction
    Choo, Ji Yung
    Goo, Jin Mo
    Lee, Chang Hyun
    Park, Chang Min
    Park, Sang Joon
    Shim, Mi-Suk
    [J]. EUROPEAN RADIOLOGY, 2014, 24 (04) : 799 - 806
  • [7] Filtered Back Projection, Adaptive Statistical Iterative Reconstruction, and a Model-based Iterative Reconstruction in Abdominal CT: An Experimental Clinical Study
    Deak, Zsuzsanna
    Grimm, Jochen M.
    Treitl, Marcus
    Geyer, Lucas L.
    Linsenmaier, Ulrich
    Koerner, Markus
    Reiser, Maximilian F.
    Wirth, Stefan
    [J]. RADIOLOGY, 2013, 266 (01) : 197 - 206
  • [8] Effects of Model-Based Iterative Reconstruction in Low-Dose Paranasal Computed Tomography: A Comparison with Filtered Back Projection and Hybrid Iterative Reconstruction
    Tomita, Hayato
    Kuramochi, Kenji
    Fujikawa, Atsuko
    Ikeda, Hirotaka
    Komita, Midori
    Kurihara, Yoshiko
    Kobayashi, Yasuyuki
    Mimura, Hidefumi
    [J]. ACTA MEDICA OKAYAMA, 2022, 76 (05) : 511 - 517
  • [9] Detection of Pulmonary Embolism on Computed Tomography Improvement Using a Model-based Iterative Reconstruction Algorithm Compared With Filtered Back Projection and Iterative Reconstruction Algorithms
    Kligerman, Seth
    Lahiji, Kian
    Weihe, Elizabeth
    Lin, Cheng Tin
    Terpenning, Silanath
    Jeudy, Jean
    Frazier, Annie
    Pugatch, Robert
    Galvin, Jeffrey R.
    Mittal, Deepika
    Kothari, Kunal
    White, Charles S.
    [J]. JOURNAL OF THORACIC IMAGING, 2015, 30 (01) : 60 - 68
  • [10] Comparison of Model-Based Iterative Reconstruction, Adaptive Statistical Iterative Reconstruction, and Filtered Back Projection for Detecting Hepatic Metastases on Submillisievert Low-Dose Computed Tomography
    Son, Jung Hee
    Kim, Seung Ho
    Yoon, Jung-Hee
    Lee, Yedaun
    Lim, Yun-Jung
    Kim, Seon-Jeong
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (04) : 644 - 650