Comparison of image quality from filtered back projection, statistical iterative reconstruction, and model-based iterative reconstruction algorithms in abdominal computed tomography

被引:24
|
作者
Kuo, Yu [1 ,2 ]
Lin, Yi-Yang [1 ,2 ]
Lee, Rheun-Chuan [1 ,2 ]
Lin, Chung-Jung [1 ,2 ]
Chiou, Yi-You [1 ,2 ]
Guo, Wan-Yuo [1 ,2 ]
机构
[1] Taipei Vet Gen Hosp, Dept Radiol, 201,Sect 2,Shipai Rd, Taipei 112, Taiwan
[2] Natl Yang Ming Univ, Sch Med, Taipei, Taiwan
关键词
abdomen; computed tomography; image quality; iterative model reconstruction; iterative reconstruction; radiation dosage; RENAL CYSTS; CT; REDUCTION; SIZE;
D O I
10.1097/MD.0000000000004456
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to compare the image noise-reducing abilities of iterative model reconstruction (IMR) with those of traditional filtered back projection (FBP) and statistical iterative reconstruction (IR) in abdominal computed tomography (CT) images This institutional review board-approved retrospective study enrolled 103 patients; informed consent was waived. Urinary bladder (n=83) and renal cysts (n=44) were used as targets for evaluating imaging quality. Raw data were retrospectively reconstructed using FBP, statistical IR, and IMR. Objective image noise and signal-to-noise ratio (SNR) were calculated and analyzed using one-way analysis of variance. Subjective image quality was evaluated and analyzed using Wilcoxon signed-rank test with Bonferroni correction. Objective analysis revealed a reduction in image noise for statistical IR compared with that for FBP, with no significant differences in SNR. In the urinary bladder group, IMR achieved up to 53.7% noise reduction, demonstrating a superior performance to that of statistical IR. IMR also yielded a significantly superior SNR to that of statistical IR. Similar results were obtained in the cyst group. Subjective analysis revealed reduced image noise for IMR, without inferior margin delineation or diagnostic confidence. IMR reduced noise and increased SNR to greater degrees than did FBP and statistical IR. Applying the IMR technique to abdominal CT imaging has potential for reducing the radiation dose without sacrificing imaging quality.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Comparison of image quality between filtered back-projection and the adaptive statistical and novel model-based iterative reconstruction techniques in abdominal CT for renal calculi
    Vardhanabhuti V.
    Ilyas S.
    Gutteridge C.
    Freeman S.J.
    Roobottom C.A.
    [J]. Insights into Imaging, 2013, 4 (5) : 661 - 669
  • [22] Abdominal CT: Comparison of Adaptive Statistical Iterative and Filtered Back Projection Reconstruction Techniques
    Singh, Sarabjeet
    Kalra, Mannudeep K.
    Hsieh, Jiang
    Licato, Paul E.
    Do, Synho
    Pien, Homer H.
    Blake, Michael A.
    [J]. RADIOLOGY, 2010, 257 (02) : 373 - 383
  • [23] Image Quality Assessment of Standard- and Low-Dose Chest CT Using Filtered Back Projection, Adaptive Statistical Iterative Reconstruction, and Novel Model-Based Iterative Reconstruction Algorithms
    Vardhanabhuti, Varut
    Loader, Robert J.
    Mitchell, Grant R.
    Riordan, Richard D.
    Roobottom, Carl A.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (03) : 545 - 552
  • [24] Model-based Iterative Reconstruction Compared to Adaptive Statistical Iterative Reconstruction and Filtered Back-projection in CT of the Kidneys and the Adjacent Retroperitoneum
    Olcott, Eric W.
    Shin, Lewis K.
    Sommer, Graham
    Chan, Ian
    Rosenberg, Jarrett
    Molvin, F. Lior
    Boas, F. Edward
    Fleischmann, Dominik
    [J]. ACADEMIC RADIOLOGY, 2014, 21 (06) : 774 - 784
  • [25] Low-Dose Computed Tomography of the Chest Using Iterative Reconstruction Versus Filtered Back Projection: Comparison of Image Quality
    Lee, Youkyung
    Jin, Kwang Nam
    Lee, Nyoung Keun
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (05) : 512 - 517
  • [26] Comparison of image quality in pediatric head computed tomography reconstructed using blended iterative reconstruction versus filtered back projection
    Ho, Chang
    Oberle, Robert
    Wu, Isaac
    Kim, Eugene
    [J]. CLINICAL IMAGING, 2014, 38 (03) : 231 - 235
  • [27] Improved Image Quality in Dual-Energy Abdominal CT: Comparison of Iterative Reconstruction in Image Space and Filtered Back Projection Reconstruction
    Wang, Rui
    Yu, Wei
    Wu, Runze
    Yang, Hua
    Lu, Dongxu
    Liu, Jiayi
    Zhang, Zhaoqi
    Zhang, Chuanchen
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (02) : 402 - 406
  • [28] Low-Dose Chest Computed Tomography With Sinogram-Affirmed Iterative Reconstruction, Iterative Reconstruction in Image Space, and Filtered Back Projection: Studies on Image Quality
    Hwang, Hye Jeon
    Seo, Joon Beom
    Lee, Hyun Joo
    Lee, Sang Min
    Kim, Eun Young
    Oh, Sang Young
    Kim, Ji-Eun
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (04) : 610 - 617
  • [29] Image quality of iterative reconstruction in cranial CT imaging: comparison of model-based iterative reconstruction (MBIR) and adaptive statistical iterative reconstruction (ASiR)
    S. Notohamiprodjo
    Z. Deak
    F. Meurer
    F. Maertz
    F. G. Mueck
    L. L. Geyer
    S. Wirth
    [J]. European Radiology, 2015, 25 : 140 - 146
  • [30] Image quality of iterative reconstruction in cranial CT imaging: comparison of model-based iterative reconstruction (MBIR) and adaptive statistical iterative reconstruction (ASiR)
    Notohamiprodjo, S.
    Deak, Z.
    Meurer, F.
    Maertz, F.
    Mueck, F. G.
    Geyer, L. L.
    Wirth, S.
    [J]. EUROPEAN RADIOLOGY, 2015, 25 (01) : 140 - 146