Comparison of image quality from filtered back projection, statistical iterative reconstruction, and model-based iterative reconstruction algorithms in abdominal computed tomography

被引:24
|
作者
Kuo, Yu [1 ,2 ]
Lin, Yi-Yang [1 ,2 ]
Lee, Rheun-Chuan [1 ,2 ]
Lin, Chung-Jung [1 ,2 ]
Chiou, Yi-You [1 ,2 ]
Guo, Wan-Yuo [1 ,2 ]
机构
[1] Taipei Vet Gen Hosp, Dept Radiol, 201,Sect 2,Shipai Rd, Taipei 112, Taiwan
[2] Natl Yang Ming Univ, Sch Med, Taipei, Taiwan
关键词
abdomen; computed tomography; image quality; iterative model reconstruction; iterative reconstruction; radiation dosage; RENAL CYSTS; CT; REDUCTION; SIZE;
D O I
10.1097/MD.0000000000004456
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to compare the image noise-reducing abilities of iterative model reconstruction (IMR) with those of traditional filtered back projection (FBP) and statistical iterative reconstruction (IR) in abdominal computed tomography (CT) images This institutional review board-approved retrospective study enrolled 103 patients; informed consent was waived. Urinary bladder (n=83) and renal cysts (n=44) were used as targets for evaluating imaging quality. Raw data were retrospectively reconstructed using FBP, statistical IR, and IMR. Objective image noise and signal-to-noise ratio (SNR) were calculated and analyzed using one-way analysis of variance. Subjective image quality was evaluated and analyzed using Wilcoxon signed-rank test with Bonferroni correction. Objective analysis revealed a reduction in image noise for statistical IR compared with that for FBP, with no significant differences in SNR. In the urinary bladder group, IMR achieved up to 53.7% noise reduction, demonstrating a superior performance to that of statistical IR. IMR also yielded a significantly superior SNR to that of statistical IR. Similar results were obtained in the cyst group. Subjective analysis revealed reduced image noise for IMR, without inferior margin delineation or diagnostic confidence. IMR reduced noise and increased SNR to greater degrees than did FBP and statistical IR. Applying the IMR technique to abdominal CT imaging has potential for reducing the radiation dose without sacrificing imaging quality.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Image Quality in the Slice-Plane of Half-Reconstructed Computed Tomography in Filtered Back Projection and Iterative Reconstruction Methods
    Tsuda, N.
    Mitsui, K.
    Oda, S.
    Tanaka, N.
    Aibe, H.
    MEDICAL PHYSICS, 2020, 47 (06) : E538 - E539
  • [42] Model-Based Iterative Reconstruction Versus Adaptive Statistical Iterative Reconstruction and Filtered Back Projection in Liver 64-MDCT: Focal Lesion Detection, Lesion Conspicuity, and Image Noise
    Shuman, William P.
    Green, Doug E.
    Busey, Janet M.
    Kolokythas, Orpheus
    Mitsumori, Lee M.
    Koprowicz, Kent M.
    Thibault, Jean-Baptiste
    Hsieh, Jiang
    Alessio, Adam M.
    Choi, Eunice
    Kinahan, Paul E.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (05) : 1071 - 1076
  • [43] Comparison of adaptive statistical iterative and filtered back projection reconstruction techniques in brain CT
    Ren, Qingguo
    Dewan, Sheilesh Kumar
    Li, Ming
    Li, Jianying
    Mao, Dingbiao
    Wang, Zhenglei
    Hua, Yanqing
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (10) : 2597 - 2601
  • [44] Patient dose and image quality in low-dose abdominal CT: a comparison between iterative reconstruction and filtered back projection
    Kataria, Bharti
    Smedby, Orjan
    ACTA RADIOLOGICA, 2013, 54 (05) : 540 - 548
  • [45] Pediatric Head CT Image Quality With Iterative Reconstruction Versus Filtered Back Projection
    Oberle, R.
    Kim, E.
    Wu, I.
    Ho, C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [46] Renovascular CT: comparison between adaptive statistical iterative reconstruction and model-based iterative reconstruction
    Noda, Y.
    Goshima, S.
    Koyasu, H.
    Shigeyama, S.
    Miyoshi, T.
    Kawada, H.
    Kawai, N.
    Matsuo, M.
    CLINICAL RADIOLOGY, 2017, 72 (10) : 901.e13 - 901.e19
  • [47] Image quality comparison of two adaptive statistical iterative reconstruction (ASiR, ASiR-V) algorithms and filtered back projection in routine liver CT
    Chen, Li-Hong
    Jin, Chao
    Li, Jian-Ying
    Wang, Ge-Liang
    Jia, Yong-Jun
    Duan, Hai-Feng
    Pan, Ning
    Guo, Jianxin
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1088):
  • [48] CT of the chest with model-based, fully iterative reconstruction: comparison with adaptive statistical iterative reconstruction
    Yasutaka Ichikawa
    Kakuya Kitagawa
    Naoki Nagasawa
    Shuichi Murashima
    Hajime Sakuma
    BMC Medical Imaging, 13
  • [49] CT of the chest with model-based, fully iterative reconstruction: comparison with adaptive statistical iterative reconstruction
    Ichikawa, Yasutaka
    Kitagawa, Kakuya
    Nagasawa, Naoki
    Murashima, Shuichi
    Sakuma, Hajime
    BMC MEDICAL IMAGING, 2013, 13
  • [50] Comparability of dental implant site ridge measurements using ultra-low-dose multidetector row computed tomography combined with filtered back-projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction
    Asma’a Abdurrahman Al-Ekrish
    Reema Al-Shawaf
    Wafa Alfaleh
    Romed Hörmann
    Wolfgang Puelacher
    Gerlig Widmann
    Oral Radiology, 2019, 35 : 280 - 286