Detection of Pulmonary Embolism on Computed Tomography Improvement Using a Model-based Iterative Reconstruction Algorithm Compared With Filtered Back Projection and Iterative Reconstruction Algorithms

被引:10
|
作者
Kligerman, Seth [1 ]
Lahiji, Kian [1 ]
Weihe, Elizabeth [1 ]
Lin, Cheng Tin [1 ]
Terpenning, Silanath [1 ]
Jeudy, Jean [1 ]
Frazier, Annie [1 ]
Pugatch, Robert [1 ]
Galvin, Jeffrey R. [1 ]
Mittal, Deepika [1 ]
Kothari, Kunal [1 ]
White, Charles S. [1 ]
机构
[1] Univ Maryland, Sch Med, Dept Radiol & Nucl Med, Baltimore, MD 21201 USA
关键词
model-based iterative reconstruction; hybrid iterative reconstruction; pulmonary embolism; computed tomography pulmonary angiography; FILTERED BACK-PROJECTION; CORONARY CT ANGIOGRAPHY; IMPROVED IMAGE QUALITY; DOSE REDUCTION; RADIATION-EXPOSURE; ABDOMINAL CT; CARDIAC CT; DIAGNOSIS; CHEST; MANAGEMENT;
D O I
10.1097/RTI.0000000000000122
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of the study was to determine whether a model-based iterative reconstruction (MBIR) technique improves diagnostic confidence and detection of pulmonary embolism (PE) compared with hybrid iterative reconstruction (HIR) and filtered back projection (FBP) reconstructions in patients undergoing computed tomography pulmonary angiography. Materials and Methods: The study was approved by our institutional review board. Fifty patients underwent computed tomography pulmonary angiography at 100kV using standard departmental protocols. Twenty-two of 50 patients had studies positive for PE. All 50 studies were reconstructed using FBP, HIR, and MBIR. After image randomization, 5 thoracic radiologists and 2 thoracic radiology fellows graded each study on a scale of 1 (very poor) to 5 (ideal) in 4 subjective categories: diagnostic confidence, noise, pulmonary artery enhancement, and plastic appearance. Readers assessed each study for the presence of PE. Parametric and nonparametric data were analyzed with repeated measures and Friedman analysis of variance, respectively. Results: For the 154 positive studies (7 readers x 22 positive studies), pooled sensitivity for detection of PE was 76% (117/154), 78.6% (121/154), and 82.5% (127/154) using FBP, HIR, and MBIR, respectively. PE detection was significantly higher using MBIR compared with FBP (P= 0.016) and HIR (P= 0.046). Because of nonsignificant increase in FP studies using HIR and MBIR, accuracy with MBIR (88.6%), HIR (87.1%), and FBP (87.7%) was similar. Compared with FBP, MBIR led to a significant subjective increase in diagnostic confidence, noise, and enhancement in 6/7, 6/7, and 7/7 readers, respectively. Compared with HIR, MBIR led to significant subjective increase in diagnostic confidence, noise, and enhancement in 5/7, 5/7, and 7/7 readers, respectively. MBIR led to a subjective increase in plastic appearance in all 7 readers compared with both FBP and HIR. Conclusions: MBIR led to significant increase in PE detection compared with FBP and HIR. MBIR led to qualitative improvements in diagnostic confidence, perceived noise, and perceived enhancement compared with FBP and HIR.
引用
收藏
页码:60 / 68
页数:9
相关论文
共 50 条
  • [1] Comparison of image quality from filtered back projection, statistical iterative reconstruction, and model-based iterative reconstruction algorithms in abdominal computed tomography
    Kuo, Yu
    Lin, Yi-Yang
    Lee, Rheun-Chuan
    Lin, Chung-Jung
    Chiou, Yi-You
    Guo, Wan-Yuo
    [J]. MEDICINE, 2016, 95 (31)
  • [2] Effects of Model-Based Iterative Reconstruction in Low-Dose Paranasal Computed Tomography: A Comparison with Filtered Back Projection and Hybrid Iterative Reconstruction
    Tomita, Hayato
    Kuramochi, Kenji
    Fujikawa, Atsuko
    Ikeda, Hirotaka
    Komita, Midori
    Kurihara, Yoshiko
    Kobayashi, Yasuyuki
    Mimura, Hidefumi
    [J]. ACTA MEDICA OKAYAMA, 2022, 76 (05) : 511 - 517
  • [3] Comparing IDREAM as an iterative reconstruction algorithm against in filtered back projection in computed tomography
    Maamoun, Islam Kamal Abdel Fattah
    [J]. Iranian Journal of Medical Physics, 2020, 17 (03): : 170 - 174
  • [4] Computed Tomography Image Quality Evaluation of a New Iterative Reconstruction Algorithm in the Abdomen (Adaptive Statistical Iterative Reconstruction-V) a Comparison With Model-Based Iterative Reconstruction, Adaptive Statistical Iterative Reconstruction, and Filtered Back Projection Reconstructions
    Goodenberger, Martin H.
    Wagner-Bartak, Nicolaus A.
    Gupta, Shiva
    Liu, Xinming
    Yap, Ramon Q.
    Sun, Jia
    Tamm, Eric P.
    Jensen, Corey T.
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (02) : 184 - 190
  • [5] Improved Accuracy of Pulmonary Embolism Computer-Aided Detection Using Iterative Reconstruction Compared With Filtered Back Projection
    Lahiji, Kian
    Kligerman, Seth
    Jeudy, Jean
    White, Charles
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (04) : 763 - 771
  • [6] Knowledge-based iterative model reconstruction in coronary computed tomography angiography: comparison with hybrid iterative reconstruction and filtered back projection
    Cha, Min Jae
    Seo, Jae Seung
    Yoo, Dong Soo
    Chong, Semin
    [J]. ACTA RADIOLOGICA, 2018, 59 (03) : 280 - 286
  • [7] Model-based Iterative Reconstruction Compared to Adaptive Statistical Iterative Reconstruction and Filtered Back-projection in CT of the Kidneys and the Adjacent Retroperitoneum
    Olcott, Eric W.
    Shin, Lewis K.
    Sommer, Graham
    Chan, Ian
    Rosenberg, Jarrett
    Molvin, F. Lior
    Boas, F. Edward
    Fleischmann, Dominik
    [J]. ACADEMIC RADIOLOGY, 2014, 21 (06) : 774 - 784
  • [8] Quantitative analysis of emphysema and airway measurements according to iterative reconstruction algorithms: comparison of filtered back projection, adaptive statistical iterative reconstruction and model-based iterative reconstruction
    Ji Yung Choo
    Jin Mo Goo
    Chang Hyun Lee
    Chang Min Park
    Sang Joon Park
    Mi-Suk Shim
    [J]. European Radiology, 2014, 24 : 799 - 806
  • [9] Comparison of image quality from filtered back projection, statistical iterative reconstruction, and model-based iterative reconstruction algorithms in abdominal computed tomography (vol 95, pg 31, 2016)
    Kuo, Y.
    Lin, Y-Y
    Lee, R-C
    [J]. MEDICINE, 2016, 95 (49)
  • [10] Quantitative analysis of emphysema and airway measurements according to iterative reconstruction algorithms: comparison of filtered back projection, adaptive statistical iterative reconstruction and model-based iterative reconstruction
    Choo, Ji Yung
    Goo, Jin Mo
    Lee, Chang Hyun
    Park, Chang Min
    Park, Sang Joon
    Shim, Mi-Suk
    [J]. EUROPEAN RADIOLOGY, 2014, 24 (04) : 799 - 806