Effect of increased crown height on stress distribution in short dental implant components and their surrounding bone: A finite element analysis

被引:63
|
作者
Bulaqi, Haddad Arabi [1 ]
Mashhadi, Mahmoud Mousavi [1 ]
Safari, Hamed [2 ]
Samandari, Mohammad Mahdi [3 ]
Geramipanah, Farideh [1 ]
机构
[1] Univ Tehran, Dept Mech Engn, Sch Mech, Tehran, Iran
[2] Qom Univ Med Sci, Sch Dent, Dept Periodont, Qom, Iran
[3] Univ Tehran, Implant Res Ctr, Dept Mech Engn, Sch Mech, Tehran, Iran
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2015年 / 113卷 / 06期
关键词
RATIO; COMPLICATIONS; RESTORATIONS; SURVIVAL; SCREWS;
D O I
10.1016/j.prosdent.2014.11.007
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Implants in posterior regions of the jaw require short dental implants with long crown heights, leading to increased crown-to-implant ratios and mechanical stress. This can lead to fracture and screw loosening. Purpose. The purpose of this study was to investigate the dynamic nature and behavior of prosthetic components and preimplant bone and evaluate the effect of increased crown height space (CHS) and crown-to-implant ratio on stress concentrations under external oblique forces. Material and methods. The severely resorbed bone of a posterior mandible site was modeled with Mimics and Catia software. A second mandibular premolar tooth was modeled with CHS values of 8.8, 11.2, 13.6, and 16 mm. A Straumann implant (4.1x8 mm), a directly attached crown, and an abutment screw were modeled with geometric data and designed by using SolidWorks software. Abaqus software was used for the dynamic simulation of screw tightening and the application of an external load to the buccal cusp at a 75.8-degree angle with the occlusal plane. The distribution of screw load and member load at each step was compared, and the stress values were calculated within the dental implant complex and surrounding bone. Results. During tightening, the magnitude and distribution of the preload and clamp load were uniform and equal at the cross section of all CHSs. Under an external load, the screw load decreased and member load increased. An increase in the CHS caused the corresponding distribution to become more nonuniform and increased the maximum compressive and tensile stresses in the preimplant bone. Additionally, the von Mises stress decreased at the abutment screw and increased at the abutment and fixture. Conclusions. Under nonaxial forces, increased CHS does not influence the decrease in screw load or increase in member load. However, it contributes to screw loosening and fatigue fracture by skewing the stress distribution to the transverse section of the implant.
引用
收藏
页码:548 / 557
页数:10
相关论文
共 50 条
  • [41] Finite-Element Analysis of Stress on Dental Implant Prosthesis
    Rubo, Jose Henrique
    Capello Souza, Edson Antonio
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2010, 12 (02) : 105 - 113
  • [42] The influence of implant body and thread design of mini dental implants on the loading of surrounding bone: a finite element analysis
    Toth, Arpad
    Hasan, Istabrak
    Bourauel, Christoph
    Mundt, Torsten
    Biffar, Reiner
    Heinemann, Friedhelm
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2017, 62 (04): : 393 - 405
  • [43] Investigation of the dental implant geometry effect on stress distribution at dental implant–bone interface
    Majid Ghadiri
    Navvab Shafiei
    Sadegh Hemmati Salekdeh
    Parya Mottaghi
    Tahereh Mirzaie
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2016, 38 : 335 - 343
  • [44] Effect of Platform Switching on Implant Crest Bone Stress: A Finite Element Analysis
    Schrotenboer, Jason
    Tsao, Yi-Pin
    Kinariwala, Vipul
    Wang, Hom-Lay
    IMPLANT DENTISTRY, 2009, 18 (03) : 260 - 265
  • [45] Finite element analysis of stress at implant-bone interface of dental implants with different structures
    Chen Liang-jian
    He Hao
    Li Yi-min
    Li Ting
    Guo Xiao-ping
    Wang Rui-fang
    TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 2011, 21 (07) : 1602 - 1610
  • [46] Optimized Dental Implant Fixture Design for the Desirable Stress Distribution in the Surrounding Bone Region: A Biomechanical Analysis
    Kim, Won Hyeon
    Lee, Jae-Chang
    Lim, Dohyung
    Heo, Young-Ku
    Song, Eun-Sung
    Lim, Young-Jun
    Kim, Bongju
    MATERIALS, 2019, 12 (17)
  • [47] The effect of implant neck microthread design on stress distribution of peri-implant bone with different level: A finite element analysis
    Jin, Zhi-Heng
    Peng, Meng-Dong
    Li, Qing
    JOURNAL OF DENTAL SCIENCES, 2020, 15 (04) : 466 - 471
  • [48] Finite element analysis of bio-inert mass effect on stress reduction in bone-dental implant interface
    Mehdi, G.
    Belarbi, A.
    Mansouri, B.
    Azari, Z.
    BIODENTAL ENGINEERING III, 2014, : 179 - 183
  • [49] Stress Distribution of Dental Posts by Finite Element Analysis
    Liu, P. H.
    Jhong, G. H.
    5TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2011 (BIOMED 2011), 2011, 35 : 219 - 221
  • [50] The Effect of Implant Thread Design on Stress Distribution in Anisotropic Bone with Different Osseointegration Conditions: A Finite Element Analysis
    Mosavar, Alireza
    Ziaei, Alireza
    Kadkhodaei, Mahmoud