Objectives: The purpose of this study was to investigate, in a model, the interaction phenomena of platform switching on the trans-cortical section of bone adjacent to an endosseous dental implant. Materials: A 2-dimensional finite, element model was fabricated to analyze the bone-implant interactions under masticatory forces. Two abutment diameters, 4.5 mm representing platform switching and 5 mm representing a standard platform, were used in conjunction with a 5-mm diameter fixture. A 100-N static force was applied vertically (90 degrees) and obliquely (15 degrees) to the abutments. All models were obtained using a reverse engineering process with values obtained from other studies to create a hypothetical implant system that demonstrates basic implant features. Results: The standard platform model demonstrated a maximum crestal Von-Mises stress of 28 and 6977 MPa under oblique and vertical loading, respectively. The platform switching model showed 27.43 and 6.502 MPa under oblique and vertical loading, respectively. This implies that a 10% reduction in abutment diameter results in a 2.04% and 6.81% decrease under oblique and vertical loading, respectively, in Von-Mises stress. The distribution pattern of forces was minimally altered between both. abutment models, with a slightly more significant change in the vertical loading scenario. Conclusions: Results from this study showed the reduction of abutment diameter (i.e., platform switching) resulted in a measurable but minimal effect on Von-Mises stress in the crestal region of cortical bone. However, future clinical trials in this area arc, warranted before any firm conclusion is drawn. (Implant Dent 2009;18:260-269)
引用
收藏
页码:260 / 265
页数:6
相关论文
共 50 条
  • [1] Effect of Microthreads and Platform Switching on Crestal Bone Stress Levels: A Finite Element Analysis
    Schrotenboer, Jason
    Tsao, Yi-Pin
    Kinariwala, Vipul
    Wang, Hom-Lay
    JOURNAL OF PERIODONTOLOGY, 2008, 79 (11) : 2166 - 2172
  • [2] Effect of platform switching on peri-implant bone: A 3D finite element analysis
    Aslam, Ayesha
    Hassan, Syed Hammad
    Aslam, Hammad Mudasser
    Khan, Danish Azeem
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (06): : 935 - 940
  • [3] The Effect of Platform Switching on Stress in Peri-implant Bone in a Condition of Marginal Bone Resorption: A Three-Dimensional Finite Element Analysis
    Xia, Haibin
    Wang, Min
    Ma, Li
    Zhou, Yi
    Li, Zhiyong
    Wang, Yining
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (03) : E122 - E127
  • [4] THE EFFECT OF PLATFORM SWITCHING ON STRESS DISTRIBUTION IN IMPLANTS AND PERIIM PLANT BONE STUDIED BY NONLINEAR FINITE ELEMENT ANALYSIS
    Liu, Siyu
    Tang, Chunbo
    Yu, Jinhua
    Dai, Wenyong
    Bao, Yidong
    Hu, Dan
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (05): : 1111 - 1118
  • [5] Biomechanical Effect of Platform Switching in Implant Dentistry: A Three-Dimensional Finite Element Analysis
    Chang, Chih-Ling
    Chen, Chen-Sheng
    Hsu, Ming-Lun
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (02) : 295 - 304
  • [6] Regular and Switching Platform: Bone Stress Analysis With Varying Implant Diameter
    Merson Vargas, Luis Carlos
    de Almeida, Erika Oliveira
    Rocha, Eduardo Passos
    Kina, Sidney
    Anchieta, Rodolfo Bruniera
    Freitas Junior, Amilcar Chagas
    Gomes Franca, Fabiana Mantovani
    JOURNAL OF ORAL IMPLANTOLOGY, 2013, 39 (03) : 326 - 332
  • [7] Regular and Platform Switching: Bone Stress Analysis Varying Implant Type
    Gurgel-Juarez, Nalia Cecilia
    de Almeida, Erika Oliveira
    Rocha, Eduardo Passos
    Freitas Junior, Amilcar Chagas
    Anchieta, Rodolfo Bruniera
    Mercon de Vargas, Luis Carlos
    Kina, Sidney
    Gomes Franca, Fabiana Mantovani
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2012, 21 (03): : 160 - 166
  • [8] Effect of Short Dental Implant Material on Bone Stress: An In Vitro Finite Element Analysis
    Al Qahtani, Waleed M. S.
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2022, 12 (09) : 1781 - 1786
  • [9] Influence of Fine Threads and Platform-Switching on Crestal Bone Stress Around Implant-A Three-Dimensional Finite Element Analysis
    Khurana, Pardeep
    Sharma, Arun
    Sodhi, Kiranmeet Kaur
    JOURNAL OF ORAL IMPLANTOLOGY, 2013, 39 (06) : 697 - 703
  • [10] Effect of implant systems in differing bone densities on peri-implant bone stress: A 3 dimensional finite element analysis
    Sahi, Aoujashwie
    Gali, Sivaranjani
    MATERIALS TODAY-PROCEEDINGS, 2022, 50 : 1300 - 1307