Effect of Platform Switching on Implant Crest Bone Stress: A Finite Element Analysis

被引:33
|
作者
Schrotenboer, Jason
Tsao, Yi-Pin [1 ]
Kinariwala, Vipul [2 ]
Wang, Hom-Lay [1 ]
机构
[1] Univ Michigan, Sch Dent, Dept Periodont & Oral Med, Ann Arbor, MI 48109 USA
[2] Cranes Software Inc, Business Dev, Troy, MI USA
关键词
platform switching; implants; numerical analysis; implant abutment; biomechanics; CANCELLOUS BONE; ELASTICITY;
D O I
10.1097/ID.0b013e31819e8c1d
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The purpose of this study was to investigate, in a model, the interaction phenomena of platform switching on the trans-cortical section of bone adjacent to an endosseous dental implant. Materials: A 2-dimensional finite, element model was fabricated to analyze the bone-implant interactions under masticatory forces. Two abutment diameters, 4.5 mm representing platform switching and 5 mm representing a standard platform, were used in conjunction with a 5-mm diameter fixture. A 100-N static force was applied vertically (90 degrees) and obliquely (15 degrees) to the abutments. All models were obtained using a reverse engineering process with values obtained from other studies to create a hypothetical implant system that demonstrates basic implant features. Results: The standard platform model demonstrated a maximum crestal Von-Mises stress of 28 and 6977 MPa under oblique and vertical loading, respectively. The platform switching model showed 27.43 and 6.502 MPa under oblique and vertical loading, respectively. This implies that a 10% reduction in abutment diameter results in a 2.04% and 6.81% decrease under oblique and vertical loading, respectively, in Von-Mises stress. The distribution pattern of forces was minimally altered between both. abutment models, with a slightly more significant change in the vertical loading scenario. Conclusions: Results from this study showed the reduction of abutment diameter (i.e., platform switching) resulted in a measurable but minimal effect on Von-Mises stress in the crestal region of cortical bone. However, future clinical trials in this area arc, warranted before any firm conclusion is drawn. (Implant Dent 2009;18:260-269)
引用
收藏
页码:260 / 265
页数:6
相关论文
共 50 条
  • [41] Finite Element Analysis of the Stress Distribution Associated With Different Implant Designs for Different Bone Densities
    Kurtulus, Ikbal Leblebicioglu
    Kilic, Kerem
    Bal, Burak
    Kilavuz, Ahmet
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (07): : 614 - 622
  • [42] Finite element analysis of stress at implant-bone interface of dental implants with different structures
    Chen Liang-jian
    He Hao
    Li Yi-min
    Li Ting
    Guo Xiao-ping
    Wang Rui-fang
    TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 2011, 21 (07) : 1602 - 1610
  • [43] Finite element analysis of mini implant biomechanics on peri-implant bone
    Hisam, Muhammad Juzaili
    Zaman, Izzuddin
    Shari, Safian
    Kurniawan, Denni
    Nor, Fethma M.
    DIGITAL MANUFACTURING TRANSFORMING INDUSTRY TOWARDS SUSTAINABLE GROWTH, 2019, 30 : 308 - 314
  • [44] Effect of Implant Position, Angulation, and Attachment Height on Peri-Implant Bone Stress Associated with Mandibular Two-Implant Overdentures: A Finite Element Analysis
    Hong, Hae Ryong
    Pae, Ahran
    Kim, Yooseok
    Paek, Janghyun
    Kim, Hyeong-Seob
    Kwon, Kung-Rock
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (05) : 1022 - 1022
  • [45] Preventing stress singularities in peri-implant bone - a finite element analysis using a graded bone model
    Roffmann, Oliver
    Stiesch, Meike
    Greuling, Andreas
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024, 27 (05) : 547 - 557
  • [46] Bone Strain and Interfacial Sliding Analyses of Platform Switching and Implant Diameter on an Immediately Loaded Implant: Experimental and Three-Dimensional Finite Element Analyses
    Hsu, Jui-Ting
    Fuh, Lih-Jyh
    Lin, Dan-Jae
    Shen, Yen-Wen
    Huang, Heng-Li
    JOURNAL OF PERIODONTOLOGY, 2009, 80 (07) : 1125 - 1132
  • [47] Three-dimensional finite element analysis of platform switched implant
    Moon, Se-Young
    Lim, Young-Jun
    Kim, Myung-Joo
    Kwon, Ho-Beom
    JOURNAL OF ADVANCED PROSTHODONTICS, 2017, 9 (01): : 31 - 37
  • [48] Effect of Implant Design on Stress Distribution: A Finite Element Study
    Houshmand B.
    Ardakani M.T.
    Moscowchi A.
    Oskoui I.Z.
    Journal of Long-Term Effects of Medical Implants, 2022, 32 (04) : 39 - 45
  • [49] Effect of angulated abutments on stress concentration at the implant abutment interface: a finite element analysis
    Shetty, M.
    Hegde, C.
    John, N.
    JOURNAL OF OSSEOINTEGRATION, 2024, 16 (02) : 106 - 113
  • [50] INVESTIGATION OF THE EFFECT OF CEMENT THICKNESS ON AN IMPLANT BY FINITE-ELEMENT STRESS-ANALYSIS
    KWAK, BM
    LIM, OK
    KIM, YY
    RIM, K
    INTERNATIONAL ORTHOPAEDICS, 1979, 2 (04) : 315 - 319