Effect of increased crown height on stress distribution in short dental implant components and their surrounding bone: A finite element analysis

被引:63
|
作者
Bulaqi, Haddad Arabi [1 ]
Mashhadi, Mahmoud Mousavi [1 ]
Safari, Hamed [2 ]
Samandari, Mohammad Mahdi [3 ]
Geramipanah, Farideh [1 ]
机构
[1] Univ Tehran, Dept Mech Engn, Sch Mech, Tehran, Iran
[2] Qom Univ Med Sci, Sch Dent, Dept Periodont, Qom, Iran
[3] Univ Tehran, Implant Res Ctr, Dept Mech Engn, Sch Mech, Tehran, Iran
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2015年 / 113卷 / 06期
关键词
RATIO; COMPLICATIONS; RESTORATIONS; SURVIVAL; SCREWS;
D O I
10.1016/j.prosdent.2014.11.007
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Implants in posterior regions of the jaw require short dental implants with long crown heights, leading to increased crown-to-implant ratios and mechanical stress. This can lead to fracture and screw loosening. Purpose. The purpose of this study was to investigate the dynamic nature and behavior of prosthetic components and preimplant bone and evaluate the effect of increased crown height space (CHS) and crown-to-implant ratio on stress concentrations under external oblique forces. Material and methods. The severely resorbed bone of a posterior mandible site was modeled with Mimics and Catia software. A second mandibular premolar tooth was modeled with CHS values of 8.8, 11.2, 13.6, and 16 mm. A Straumann implant (4.1x8 mm), a directly attached crown, and an abutment screw were modeled with geometric data and designed by using SolidWorks software. Abaqus software was used for the dynamic simulation of screw tightening and the application of an external load to the buccal cusp at a 75.8-degree angle with the occlusal plane. The distribution of screw load and member load at each step was compared, and the stress values were calculated within the dental implant complex and surrounding bone. Results. During tightening, the magnitude and distribution of the preload and clamp load were uniform and equal at the cross section of all CHSs. Under an external load, the screw load decreased and member load increased. An increase in the CHS caused the corresponding distribution to become more nonuniform and increased the maximum compressive and tensile stresses in the preimplant bone. Additionally, the von Mises stress decreased at the abutment screw and increased at the abutment and fixture. Conclusions. Under nonaxial forces, increased CHS does not influence the decrease in screw load or increase in member load. However, it contributes to screw loosening and fatigue fracture by skewing the stress distribution to the transverse section of the implant.
引用
收藏
页码:548 / 557
页数:10
相关论文
共 50 条
  • [31] Stress and strain distribution behavior in the bone due to the effect of cancellous bone, dental implant material and the bone height
    Hedia, HS
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2002, 12 (02) : 111 - 119
  • [32] Stress Distribution on Bone and Implant by Three-dimensional Finite Element Analysis
    Cheng, Hsin-Chung
    Huang, Chiung-Fang
    Lin, Yi
    Shen, Yung-Kang
    JOURNAL OF THE CHINESE SOCIETY OF MECHANICAL ENGINEERS, 2014, 35 (05): : 389 - 395
  • [33] Stress Distribution in Cortical Bone around the Basal Implant - A Finite Element Analysis
    Roy, Anip Kumar
    Dixit, Nivedita
    Punde, Prashant
    Sinha, Koshika Tondon
    Jalaluddin, Mohammad
    Kumar, Ashish
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2021, 13 (05): : 633 - 636
  • [34] The Effect of Crown/Implant Ratio and Crown Height Space on Stress Distribution in Unsplinted Implant Supporting Restorations
    Nissan, Joseph
    Ghelfan, Oded
    Gross, Ora
    Priel, Ilan
    Gross, Martin
    Chaushu, Gavriel
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 69 (07) : 1934 - 1939
  • [35] Angled abutments result in increased or decreased stress on surrounding bone of single-unit dental implants: A finite element analysis
    Tian, Kebin
    Chen, Jiang
    Han, Lilin
    Yang, Jin
    Huang, Wenxiu
    Wu, Dong
    MEDICAL ENGINEERING & PHYSICS, 2012, 34 (10) : 1526 - 1531
  • [36] Effect of Integration Patterns Around Implant Neck on Stress Distribution in Peri-Implant Bone: A Finite Element Analysis
    Han, Jingyun
    Sun, Yuchun
    Wang, Chao
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2017, 26 (06): : 549 - 558
  • [37] Effect of Proximal Wall Height on All-Ceramic Crown Core Stress Distribution: A Finite Element Analysis Study
    Coelho, Paulo G.
    Silva, Nelson R.
    Thompson, Van P.
    Rekow, E. Dianne
    Zhang, Guangming
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2009, 22 (01) : 78 - 86
  • [38] The effect of ferrule height on stress distribution within a tooth restored with fibre posts and ceramic crown: A finite element analysis
    Juloski, Jelena
    Apicella, Davide
    Ferrari, Marco
    DENTAL MATERIALS, 2014, 30 (12) : 1304 - 1315
  • [39] Effect of short implant crown-to-implant ratio on stress distribution in anisotropic bone with different osseointegration rates
    Yuan, Xi
    Liu, Yuchen
    Yang, Yunhe
    Ren, Mingfa
    Luo, Lailong
    Zheng, Lang
    Liu, Yang
    BMC ORAL HEALTH, 2023, 23 (01)
  • [40] Effect of short implant crown-to-implant ratio on stress distribution in anisotropic bone with different osseointegration rates
    Xi Yuan
    Yuchen Liu
    Yunhe Yang
    Mingfa Ren
    Lailong Luo
    Lang Zheng
    Yang Liu
    BMC Oral Health, 23