Stress Distribution in Cortical Bone around the Basal Implant - A Finite Element Analysis

被引:1
|
作者
Roy, Anip Kumar [1 ]
Dixit, Nivedita [1 ]
Punde, Prashant [2 ]
Sinha, Koshika Tondon [3 ]
Jalaluddin, Mohammad [4 ]
Kumar, Ashish
机构
[1] Inst Dent Sci, Dept Prosthodont, Baeilly, Uttar Pradesh, India
[2] Krishna Inst Med Sci Deemed Univ, Sch Dent Sci, Dept Oral & Maxillofacial Surg, Karad, Maharashtra, India
[3] Purvanchal Inst Dent Sci, Dept Prosthodont, Gorakhpur, Uttar Pradesh, India
[4] KIIT Deemed Univ, Kalinga Inst Dent Sci, Dept Periodont & Oral Implantol, Bhubaneswar, Odisha, India
来源
关键词
Basal implant; cortical bone; finite element analysis; stress;
D O I
10.4103/jpbs.JPBS_679_20
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Aim: The aim of the study was to develop a model that represents a basal implant with stress distribution in the cortical bone on application of loads emulating masticatory forces. Materials and Methods: In this study, the stress distribution in the bone and the implant is evaluated by applying various loads that emulate the masticatory forces. The geometric models of cortical bone representing the premolar area and a basal implant model of the following specifications, longitudinal oval threaded pin (1.95 mm x 2.1/2.3 mm o), height of the implant head (7.2 mm), and width of the implant head (3.5 mm) (BOI BS, IDHEDENTAL), were generated with Ansys software, and both the implant model and the bone model are superimposed to mimic the bone implant system as a unit. Results: Overall comparison of stress distribution on both implant shaft and implant neck showed that maximum stresses are located at implant neck irrespective of forces applied and minimum stresses are located at implant shaft. On overall comparison of stresses seen within the bone and the implant, it was observed that the maximum stresses were seen in the implant neck followed by the implant shaft followed by the bone interface. Conclusion: The present study concluded that the stress transmission is greatest during application of oblique load (70 N) followed by horizontal load (10 N) and the least by vertical load (35 N).
引用
收藏
页码:633 / 636
页数:4
相关论文
共 50 条
  • [1] Effect of Integration Patterns Around Implant Neck on Stress Distribution in Peri-Implant Bone: A Finite Element Analysis
    Han, Jingyun
    Sun, Yuchun
    Wang, Chao
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2017, 26 (06): : 549 - 558
  • [2] Finite Element Analysis and Experimental Investigations on Stress Distribution of Dental Implants around Implant-Bone Interface
    Dhatrak, Pankaj
    Shirsat, Uddhav
    Sumanth, S.
    Deshmukh, Vijay
    MATERIALS TODAY-PROCEEDINGS, 2018, 5 (02) : 5641 - 5648
  • [3] Finite element analysis of stress distribution around a dental implant with different amounts of bone loss: An in vitro study
    Jafarian, Mohammad
    Mirhashemi, Fatemeh Sadat
    Emadi, Naghmeh
    DENTAL AND MEDICAL PROBLEMS, 2019, 56 (01) : 27 - 32
  • [4] Influence of cortical bone quality on stress distribution in bone around dental implant
    Kitagawa, T
    Tanimoto, Y
    Nemoto, K
    Aida, M
    DENTAL MATERIALS JOURNAL, 2005, 24 (02) : 219 - 224
  • [5] Stress Distribution on Bone and Implant by Three-dimensional Finite Element Analysis
    Cheng, Hsin-Chung
    Huang, Chiung-Fang
    Lin, Yi
    Shen, Yung-Kang
    JOURNAL OF THE CHINESE SOCIETY OF MECHANICAL ENGINEERS, 2014, 35 (05): : 389 - 395
  • [6] Influence of maxillary cortical bone thickness, implant design and implant diameter on stress around implants: A three-dimensional finite element analysis
    Okumura, Nobuaki
    Stegaroiu, Roxana
    Kitamura, Eriko
    Kurokawa, Kouichi
    Nomura, Shuichi
    JOURNAL OF PROSTHODONTIC RESEARCH, 2010, 54 (03) : 133 - 142
  • [7] Finite element modelling of implant designs and cortical bone thickness on stress distribution in maxillary type IV bone
    Chou, I-Chiang
    Lee, Shyh-Yuan
    Wu, Ming-Chang
    Sun, Chia-Wei
    Jiang, Cho-Pei
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2014, 17 (05) : 516 - 526
  • [8] The effect of thread geometry on the stress distribution in the bone around implant: 2-D finite element analysis.
    Salimee, P
    Thanapalin, T
    Dechaumphai, P
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 648 - 648
  • [9] Influence of implant design and bone quality on stress/strain distribution in bone around implants: A 3-dimensional finite element analysis
    Tada, S
    Stegaroiu, R
    Kitamura, E
    Miyakawa, O
    Kusakari, H
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2003, 18 (03) : 357 - 368
  • [10] Influence of Implant/Abutment Connection on Stress Distribution to Implant-Surrounding Bone: A Finite Element Analysis
    Hanaoka, Marcia
    Alexandre Gehrke, Sergio
    Mardegan, Fabio
    Gennari, Cesar Roberto
    Taschieri, Silvio
    Del Fabbro, Massimo
    Corbella, Stefano
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2014, 23 (07): : 565 - 571