Stress Distribution in Cortical Bone around the Basal Implant - A Finite Element Analysis

被引:1
|
作者
Roy, Anip Kumar [1 ]
Dixit, Nivedita [1 ]
Punde, Prashant [2 ]
Sinha, Koshika Tondon [3 ]
Jalaluddin, Mohammad [4 ]
Kumar, Ashish
机构
[1] Inst Dent Sci, Dept Prosthodont, Baeilly, Uttar Pradesh, India
[2] Krishna Inst Med Sci Deemed Univ, Sch Dent Sci, Dept Oral & Maxillofacial Surg, Karad, Maharashtra, India
[3] Purvanchal Inst Dent Sci, Dept Prosthodont, Gorakhpur, Uttar Pradesh, India
[4] KIIT Deemed Univ, Kalinga Inst Dent Sci, Dept Periodont & Oral Implantol, Bhubaneswar, Odisha, India
来源
关键词
Basal implant; cortical bone; finite element analysis; stress;
D O I
10.4103/jpbs.JPBS_679_20
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Aim: The aim of the study was to develop a model that represents a basal implant with stress distribution in the cortical bone on application of loads emulating masticatory forces. Materials and Methods: In this study, the stress distribution in the bone and the implant is evaluated by applying various loads that emulate the masticatory forces. The geometric models of cortical bone representing the premolar area and a basal implant model of the following specifications, longitudinal oval threaded pin (1.95 mm x 2.1/2.3 mm o), height of the implant head (7.2 mm), and width of the implant head (3.5 mm) (BOI BS, IDHEDENTAL), were generated with Ansys software, and both the implant model and the bone model are superimposed to mimic the bone implant system as a unit. Results: Overall comparison of stress distribution on both implant shaft and implant neck showed that maximum stresses are located at implant neck irrespective of forces applied and minimum stresses are located at implant shaft. On overall comparison of stresses seen within the bone and the implant, it was observed that the maximum stresses were seen in the implant neck followed by the implant shaft followed by the bone interface. Conclusion: The present study concluded that the stress transmission is greatest during application of oblique load (70 N) followed by horizontal load (10 N) and the least by vertical load (35 N).
引用
收藏
页码:633 / 636
页数:4
相关论文
共 50 条
  • [41] Influence of Implant Length, Diameter, and Geometry on Stress Distribution: A Finite Element Analysis
    Anitua, Eduardo
    Tapia, Raul
    Luzuriaga, Felipe
    Orive, Gorka
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2010, 30 (01) : 89 - 95
  • [42] Influence of restoration type on stress distribution in bone around implants: A three-dimensional finite element analysis
    Stegaroiu, R
    Sato, T
    Kusakari, H
    Miyakawa, O
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1998, 13 (01) : 82 - 90
  • [43] Comparative Evaluation of the Effect of Implant Crown Materials on Implant Components and Bone Stress Distribution: A 3D Finite Element Analysis
    Nokar, Kimia
    Atri, Faezeh
    Nokar, Saied
    INTERNATIONAL JOURNAL OF DENTISTRY, 2023, 2023
  • [44] Effect of vertical bone loss on stress distribution at the bone-implant interface around implants of varying diameters-an in silico 3D finite element analysis
    Gupta, Shipra
    Chopra, Priyanka
    Goyal, Parveen
    Jain, Ashish
    MATERIALS TODAY-PROCEEDINGS, 2021, 45 : 4581 - 4586
  • [45] A Three-dimensional Finite Element Analysis of Effect of Abutment Materials on Stress Distribution around Peri-Implant Bone in Immediate and Delayed Loading Conditions
    AGARWAL, S. A. U. M. Y. A.
    TRIVEDI, A. N. S. H. U. L.
    KUSUM, C. H. A. N. D. A. N. K.
    GOSWAM, R. O. M. A., I
    MOWAR, A. P. O. O. R. V. A.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2022, 16 (06) : ZC55 - ZC60
  • [46] Finite element method to evaluate effects of hip implant geometry on bone cement stress distribution
    Son, Yang W.
    Wentz, Douglas H.
    Levine, Danny L.
    Johnson, Todd S.
    PROCEEDING OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2007, 2007, : 693 - 694
  • [47] Impact of Bone Augmentation of Facial Bone Defect around Osseointegrated Implant: A Three Dimensional Finite Element Analysis
    Hudieb, Malik
    AlKhader, Mustafa
    Mortaja, Salah
    Abusamak, Mohammad
    Wakabayashi, Noriyuki
    Kasugai, Shohei
    DENTISTRY JOURNAL, 2021, 9 (10)
  • [48] The Influence of Implant Number on Stress Distribution in the Anterior Region of Mandible Reconstructed with Fibula Bone Graft: A Finite Element Analysis
    Latifi, Fatemeh
    Tabrizi, Reza
    Kordkheili, Mohammadreza Hosseini
    Shahbazi, Soheil
    Fernandes, Gustavo Vicentis Oliveira
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2024,
  • [49] Effect of different design of abutment and implant on stress distribution in 2 implants and peripheral bone: A finite element analysis study
    Kul, Esra
    Korkmaz, Ismail Hakki
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (05): : 664.e1 - 664.e9
  • [50] Comparison of the effects of different implant apical designs on the magnitude and distribution of stress and strain in bone: A finite element analysis study
    Kadkhodazadeh, Mahdi
    Lafzi, Ardeshir
    Raoofi, Saeed
    Khademi, Maryam
    Amid, Reza
    Movahhedy, Mohammad Reza
    Torabi, Hasti
    Journal of Long-Term Effects of Medical Implants, 2014, 24 (2-3) : 109 - 120