Effect of increased crown height on stress distribution in short dental implant components and their surrounding bone: A finite element analysis

被引:63
|
作者
Bulaqi, Haddad Arabi [1 ]
Mashhadi, Mahmoud Mousavi [1 ]
Safari, Hamed [2 ]
Samandari, Mohammad Mahdi [3 ]
Geramipanah, Farideh [1 ]
机构
[1] Univ Tehran, Dept Mech Engn, Sch Mech, Tehran, Iran
[2] Qom Univ Med Sci, Sch Dent, Dept Periodont, Qom, Iran
[3] Univ Tehran, Implant Res Ctr, Dept Mech Engn, Sch Mech, Tehran, Iran
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2015年 / 113卷 / 06期
关键词
RATIO; COMPLICATIONS; RESTORATIONS; SURVIVAL; SCREWS;
D O I
10.1016/j.prosdent.2014.11.007
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Implants in posterior regions of the jaw require short dental implants with long crown heights, leading to increased crown-to-implant ratios and mechanical stress. This can lead to fracture and screw loosening. Purpose. The purpose of this study was to investigate the dynamic nature and behavior of prosthetic components and preimplant bone and evaluate the effect of increased crown height space (CHS) and crown-to-implant ratio on stress concentrations under external oblique forces. Material and methods. The severely resorbed bone of a posterior mandible site was modeled with Mimics and Catia software. A second mandibular premolar tooth was modeled with CHS values of 8.8, 11.2, 13.6, and 16 mm. A Straumann implant (4.1x8 mm), a directly attached crown, and an abutment screw were modeled with geometric data and designed by using SolidWorks software. Abaqus software was used for the dynamic simulation of screw tightening and the application of an external load to the buccal cusp at a 75.8-degree angle with the occlusal plane. The distribution of screw load and member load at each step was compared, and the stress values were calculated within the dental implant complex and surrounding bone. Results. During tightening, the magnitude and distribution of the preload and clamp load were uniform and equal at the cross section of all CHSs. Under an external load, the screw load decreased and member load increased. An increase in the CHS caused the corresponding distribution to become more nonuniform and increased the maximum compressive and tensile stresses in the preimplant bone. Additionally, the von Mises stress decreased at the abutment screw and increased at the abutment and fixture. Conclusions. Under nonaxial forces, increased CHS does not influence the decrease in screw load or increase in member load. However, it contributes to screw loosening and fatigue fracture by skewing the stress distribution to the transverse section of the implant.
引用
收藏
页码:548 / 557
页数:10
相关论文
共 50 条
  • [21] Effect of crown-to-implant ratio on peri-implant stress: A finite element analysis
    Verri, Fellippo Ramos
    de Souza Batista, Victor Eduardo
    Santiago, Joel Ferreira, Jr.
    de Faria Almeida, Daniel Augusto
    Pellizzer, Eduardo Piza
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 45 : 234 - 240
  • [22] Effects of diameters of implant and abutment screw on stress distribution within dental implant and alveolar bone: A threedimensional finite element analysis
    Shen, Yen -Wen
    Huang, Heng-Li
    Hsu, Jui-Ting
    Fuh, Lih-Jyh
    JOURNAL OF DENTAL SCIENCES, 2024, 19 (02) : 1126 - 1134
  • [23] Finite element analysis of stress distribution around a dental implant with different amounts of bone loss: An in vitro study
    Jafarian, Mohammad
    Mirhashemi, Fatemeh Sadat
    Emadi, Naghmeh
    DENTAL AND MEDICAL PROBLEMS, 2019, 56 (01) : 27 - 32
  • [24] Finite Element Analysis and Experimental Investigations on Stress Distribution of Dental Implants around Implant-Bone Interface
    Dhatrak, Pankaj
    Shirsat, Uddhav
    Sumanth, S.
    Deshmukh, Vijay
    MATERIALS TODAY-PROCEEDINGS, 2018, 5 (02) : 5641 - 5648
  • [25] Finite Element Analysis of Stress in Dental Bridge with Implant
    Huang, Wan-Ting
    Cheng, Han-Yi
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2020, 10 (06) : 743 - 748
  • [26] Effect of Offset Implant Placement on the Stress Distribution Around a Dental Implant: A Three-Dimensional Finite Element Analysis
    Siadat, Hakimeh
    Hashemzadeh, Shervin
    Geramy, Allahyar
    Bassir, Seyed Hossein
    Alikhasi, Marzieh
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (06) : 646 - 651
  • [27] Influence of Coefficient of Friction on Stress Distribution in Implant Components and Surrounding Bone
    Hamed, Mohamed Tharwat
    Mously, Hisham Abdullah
    Hashem, Abou Bakr Hosam
    Naguib, Ghada Hussein
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2019, 7 (06): : 48 - 53
  • [28] Stress dissipation in the bone through various crown materials of dental implant restoration: a 2-D finite element analysis
    Bijjargi, Supriya
    Chowdhary, Ramesh
    JOURNAL OF INVESTIGATIVE AND CLINICAL DENTISTRY, 2013, 4 (03) : 172 - 177
  • [29] Photoelastic Analysis of Fixed Partial Prosthesis Crown Height and Implant Length on Distribution of Stress in Two Dental Implant Systems
    Figueiredo, Evandro Portela
    Sigua-Rodriguez, Eder Alberto
    Pimentel, Marcele Jardim
    OliveiraMoreira, Ana Regina
    de Arruda Nobilo, Mauro Antonio
    de Albergaria-Barbosa, Jose Ricardo
    INTERNATIONAL JOURNAL OF DENTISTRY, 2014, 2014
  • [30] Effects of crown retrieval on implants and the surrounding bone: a finite element analysis
    Ozkir, Serhat Emre
    Unal, Server Mutluay
    Yurekli, Emel
    Guven, Sedat
    JOURNAL OF ADVANCED PROSTHODONTICS, 2016, 8 (02): : 131 - 136